Labconco Purifier Axiom 30461 Series Technical Manual And Specifications (164 pages)
Type C1 Biosafety Cabinet
Brand:
Labconco
| Category:
Laboratory Equipment
| Size: 7 MB
Table of Contents
Table of Contents
3
Introduction
7
Contacting Labconco
7
Background Information
8
Quickstarts
8
Quick Start
9
What's the Password for the Axiom
9
How Do I See the Current Settings
12
How Do I Change the Configuration
13
How Do I Run a Diagnostic on the Sash Position Switches
15
Keypad, Relays and Contact
16
Inlet Relief Valve
17
Airflow Sensor
18
How Do I Set up Automatic Operation of the Blower & Lights
19
Axiom Filter Life Gauge Operation and Resetting for Local Conditions
20
Axiom Type C1 Purifiers
21
Identifying Axiom Models
24
Serial Number Tags
25
Model Numbering System
25
Axiom Data Plate
27
Final Inspection and Test Report
28
Theory of Operation
29
Background
29
Airflow Patterns and Features
29
Chem-Zone TM Directly Exhausted Work Zone
30
Inlet Relief Valve
31
Exhaust System
31
Exhaust System Alarm
32
Airflow Patterns of Axiom
33
ECM Motor
33
Electronics
35
Section Two - Installation Requirements
37
Prerequisites
37
Space Requirements
37
Clearance
37
Location Requirements
38
If You Intend to Connect the Axiom to an Exhaust System
39
Electrical Requirements
42
Service Line Requirements
43
Section Three - Installation
45
Unpacking the Biosafety Cabinet
46
Preparing the Biosafety Cabinet for Operation
46
Moving and Lifting the Cabinet
47
Installing the Biosafety Cabinet on an Existing Work Surface
47
Installing the Cabinet on a Labconco Base Stand
48
Telescoping Base Stands
48
Manual or Electric Lift Base Stands
48
Solo Electric Hydraulic Lift Base Stands
48
Optional Exhaust System Connection Requirements
49
Configuring for an Exhaust System Connection
50
Mechanical Configuration
50
Electronic Configuration
51
Connecting the Biosafety Cabinet to Utility Service Lines
57
Optional Vacu-Pass Cord and Cable Portal
58
Drain Valve Installation (Optional)
59
Section Four - Initial Operation of the Axiom
61
System Reset Switch
61
Information Center
62
Filter Life
62
Alarm Screens
63
Operating the Sliding Sash
64
Starting the Biosafety Cabinet
64
The Axiom Touchpad
65
Navigating the Axiom Menu Screens
66
Navigating the Mylogic Menu Screens
67
Setting the Clock
67
Configuring the Axiom
68
Navigating the Settings Menu Screens
69
Display Options
69
Units of Measure
69
Startup Tone
70
Security Lock
70
Output
70
UV Settings
71
UV Lamp Hourmeter
71
Reset UV Lamp Hourmeter
71
Change UV Lamp Life
71
Timer Operation
72
Interval Timer Operation
72
Stopwatch Timer Operation
72
If an Airflow Alert Activates
72
Resetting the Airflow Alert System
72
Accessing the Certifier's Menu
73
Adjusting the Inflow, Downflow and Filter Life Gauges
73
Axiom Filter Life Gauge Operation and Resetting for Local Conditions
75
HEPA Filter Leak Test Information
76
Supply HEPA Filter Leak Test
76
If the Axiom Is Contaminated
77
Supply HEPA Filter Leak Test Specifications
77
If the Axiom Is Uncontaminated
77
Exhaust HEPA Filter Leak Test
80
Exhaust HEPA Filter Leak Test Specifications
80
Downflow Velocities
82
Downflow Test Specifications
82
Primary Inflow Method
83
Secondary Inflow Method
84
Concurrent Balance Values
88
Work Area Air Cleanliness Test (Optional)
89
Fluorescent Light Level (Optional)
90
Noise Level (Optional)
90
Vibration (Optional)
91
UV Intensity (Optional)
91
Ground Fault Circuit Interrupter
92
Recommended Tools for Service
93
External Dress Components
94
Front Dress Panel Removal and Installation
94
Side Panel Removal
95
Side Panel Installation
95
Corner Post Lower Trim
95
Sash Operation/Adjustment
97
Sash Position Switches
98
Sash Closure Position Switch
98
Sash Restricted Opening Switch
98
8" and 10" Sash Operating Position Switches
99
Sash Cable Retainer
100
HEPA Filter Replacement
100
Supply Motor/Blower Replacement
103
Exhaust Motor/Blower Replacement
105
Center Work Surface Removal
107
Wing Work Surfaces Removal
107
Grille Removal
109
Diffuser Removal
110
Preparing the Logic for Gaseous Sterilization
112
Section Seven -Electrical System Service Operations
113
Fluorescent Lamp
113
Lamp Identification
113
Changing the Fluorescent Lamp
113
Lamp Socket Replacement
114
Optional Ultraviolet Lamp
114
Lamp Identification
114
UV Lamp Specifications
114
Changing the UV Lamp
115
Lamp Socket Replacement
115
Electronics Module Access
116
Electronic Module Component Identification
116
Resetting a Circuit Breaker
117
Circuit Breaker Specifications
117
Testing a Circuit Breaker
118
Replacing a Circuit Breaker
118
Power Supply Board Service Operations
119
Fuse Testing & Replacement
119
Display Board Service Operations
120
Touchpad Connections
120
Diagnostic Operations
121
Motor Service Operations
121
Motor Testing
121
Motor Output Signal Testing
124
Wiring Diagrams
125
Section Eight - Purifier Axiom Accessories
127
Air Flow Sensor Kit and Calibration
127
Service Fixture Kit
133
Lamp Kit
135
Bar Kit
138
Installation Procedure
138
Vacu-Pass Cord & Cable Portal
139
RS-232 Connection Kits
140
Wire Color
142
Using the RS-232 Receptacle
143
Connection for Computer Interface
143
Optional Axiom RS-232 Data Output
144
Axiom Relay Contact Outputs
147
Section Nine - Miscellaneous
152
Troubleshooting
152
Purifier Logic Replacement Parts
156
Dimensions
157
Section Ten - Vacuum Start Switch (VSS)
160
Background
160
VSS Diagnostic Screens
161
VSS Calibration
163
Advertisement
Labconco Purifier Axiom 30461 Series User Manual (71 pages)
Biological Safety Cabinet
Brand:
Labconco
| Category:
Laboratory Equipment
| Size: 3 MB
Table of Contents
Table of Contents
4
Chapter 1: Introduction
7
Chapter 2: Prerequisites
8
Space Requirements
8
Clearance
8
Location Requirements
9
Exhaust Requirements
10
Electrical Requirements
12
Service Line Requirements
13
Chapter 3: Getting Started
14
Unpacking the Biosafety Cabinet
15
Moving and Lifting the Biosafety Cabinet
15
Installing the Biosafety Cabinet on an Existing Work Surface
16
Installing the Biosafety Cabinet on a Labconco Base Stand
16
Telescoping Base Stands
16
Manual or Electric Hydraulic Lift Base Stands
16
Solo Electric Hydraulic Lift Base Stands
17
Preparing the Biosafety Cabinet for Operation
17
Connecting the Biosafety Cabinet to Utility Service Lines
18
Optional Exhaust Connection Requirements
19
Exhaust Connection Configuration
20
Connecting the Axiom to an Exhaust System
20
Selecting the Configuration Menu
21
Disconnecting the Axiom from an Exhaust System
24
Selecting the Configuration Menu
25
Optional Vacu-Pass TM Cord and Cable Portal Use
27
Drain Valve Installation
28
Initial Certification
29
Chapter 4: Performance Features and Safety Precautions
30
HEPA Filters
31
ULPA Filters
31
Laminar Airflow
32
Directional Airflow
33
Chem-Zone Directly Exhausted Work Zone
34
Motor/Blowers
35
Cabinet Air Intakes (Grilles)
36
Ultraviolet (UV) Lamp
36
Safety Precautions
37
Chapter 5: Using the Cabinet
39
System Reset Switch
39
Blower Startup Sequence
39
Information Center
40
Alarm Screens
41
Operating the Sliding Sash
42
Starting the Biosafety Cabinet
42
The Axiom Touchpad
43
Navigating the Axiom Menu Screens
44
Navigating the Mylogic TM Menu Screens
45
Setting the Clock
45
Configuring the Axiom
46
Navigating the Settings Menu Screens
47
Display Options
47
Units of Measure
47
Startup Tone
48
Security Lock
48
RS-232 Output Rate
48
UV Settings
49
UV Lamp Hourmeter
49
Reset UV Lamp Hourmeter
49
Change UV Lamp Life
50
Service Menu Screens
50
Timer Operation
50
Interval Timer Operation
50
Stopwatch Timer Operation
51
If an Airflow Alert Activates
51
Resetting the Airflow Alert System
51
Working in the Biosafety Cabinet
51
Chapter 6: Maintaining the Cabinet
55
Routine Maintenance Schedule
55
Service Operations
56
Center Work Surface Removal
56
Wing Work Surfaces Removal
57
Front Grille Removal
58
Front Panel Removal & Installation
59
Changing the Fluorescent Lamps
60
Changing the Optional UV Lamp
60
Resetting a Circuit Breaker
60
Storage
61
Chapter 7: Troubleshooting
62
Appendix A: Components
65
Appendix B: Dimensions
67
Appendix C: Specifications
69
Electrical Data
69
Motor Specifications
69
Environmental Conditions
69
Appendix D: Accessories
70
Appendix E: Quick Chart
71
Advertisement
Related Products
Labconco Purifier Axiom 30441 Series
Labconco Purifier Axiom 30468 Series
Labconco Purifier Axiom 30448 Series
labconco Protector Airo 184 Series
labconco Protector Airo 184300000 Series
labconco Protector Airo 184310000 Series
labconco Protector Airo 184410000 Series
Labconco Logic+ A2
Labconco Purifier Digital Delta 3880000 Series
Labconco Purifier Digital Delta 3880100 Series
Labconco Categories
Laboratory Equipment
Ventilation Hood
Dryer
Enclosure
Fan
More Labconco Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL