Sign In
Upload
Manuals
Brands
Inficon Manuals
Security Sensors
580-010
Inficon 580-010 Manuals
Manuals and User Guides for Inficon 580-010. We have
5
Inficon 580-010 manuals available for free PDF download: Original Operating Instructions, Quick Start Manual
Inficon 580-010 Original Operating Instructions (128 pages)
Portable Methane Leak Detector
Brand:
Inficon
| Category:
Security Sensors
| Size: 8.68 MB
Table of Contents
Table of Contents
3
1 About These Instructions
7
Target Groups
7
Warnings
7
2 Safety
8
Intended Use
8
Special Conditions for Safe Use
9
Intrinsic Safety (Ex Protection)
9
Certified Gas Measurement
10
Owner/Supervisor Responsibilities
11
Duties of the Operator
12
Safe Operation
12
3 Scope of Delivery
13
4 Description
14
Function
14
Design of the Leak Detector
15
Probes
16
Display
19
Technical Data
22
EX Certification (Intrinsic Safety)
24
Sensors
24
Factory Settings
32
Concentration of Calibration and Test Gases
34
5 Getting Started
35
Charging the Battery
35
Assembling the Probe System
38
Transfer Data to Computer
40
Install Software for Data Transfer
40
Pairing the Leak Detector with Computer Via Bluetooth Interface
40
Transfer Log Files from Leak Detector to Computer
41
Real-Time Streaming from Leak Detector to Computer
41
6 Operation
43
Switch on
43
Initial Setup
44
Select Available Operating Modes
44
Adjust the Local Time
44
Setting the Language
44
Change Permission Level
45
PPM Adjustment Factor
45
Select Gas (Ex)
45
100% CH4 LEL Conc
46
Universal Mode
46
Abg Cal Setup
46
Abg Fnc Test Conc
46
Screensaver Timeout
47
Configure Data Logging
48
Enable Dead Band Suppression (Irwin Sxnn Only)
48
Setting the Function Test Interval
48
Calibration
49
Standard Calibration Procedures
51
Setting of Calibration Gas Concentrations
52
Adjust Calibration Reminder
53
Operating Modes
54
Select Operating Mode
54
Operating Mode "Above Ground
54
Operating Mode "Universal
56
Operating Mode "Bar Hole
58
Automatic "Bar Hole" Testing
59
Setting Parameters for "Auto Bar Hole
60
Operating Mode "GC Ethane Analysis
61
Operating Mode "Confined Space
65
Operating Mode "House
67
Operating Mode "Gas Purity
68
Operating Mode "Ex
70
Operating Mode "Ex Tox
73
Change Gas Type for %LEL Measurement
75
Entering Ethane Concentration Manually
76
IR Ethane Analysis and Compensation
76
Performing IR Ethane Analysis after Automatic Reminder
77
Setting Reminder for IR Ethane Analysis
77
Starting IR Ethane Analysis Manually
78
Set Limits and Alarm Levels
79
Viewing IR Ethane Analysis Info
79
Performing Function Tests
80
Set the Brightness of the Display
80
Measuring
81
Perform Self Test
82
Viewing Status Menu
82
Logging Data to File
82
Viewing Logfile List
83
Information
83
Retrieve Information and Statistics
83
Viewing the Service Screen
83
Activating Auto-Rotate Screen
83
Switching off
84
Warnings and Error Messages
84
7 Maintenance
89
Maintenance Plan
89
Spare Parts List
89
General Check of the Probe System
90
Maintenance of the Leak Detector
91
Seasonal Shut-Down
91
Change the Cigarette Filter in the Sample Inlet
91
Maintenance of the Hand Probe
91
Maintenance of the Carpet Probe
92
Maintenance of the Bell Probe
93
Maintenance of the Swan Neck
94
Maintenance of the Bar Hole Probe
94
8 Decommissioning the Leak Detector
95
Sending in the Leak Detector
95
Disposing of the Equipment
97
9 Certificates
98
TÜV, Certificate for Lower Explosive Limit (LEL)
100
Certificate for Oxygen and Toxic Gases
104
Certificate for Software for Ex/Extox
106
ATEX Certificate for Explosion Protection (Irwin Sxnn)
107
CSA (Us/Canada) Certificate for Explosion Protection (Irwin Sxnn)
108
Iecex Certificate for Explosion Protection (Irwin Sxnn)
109
NEPSI (China) Certificate for Explosion Protection
112
CE Declaration of Conformity
118
Index
124
Advertisement
Inficon 580-010 Original Operating Instructions (116 pages)
Portable Methane Leak Detector
Brand:
Inficon
| Category:
Security Sensors
| Size: 6.59 MB
Table of Contents
Table of Contents
3
About These Instructions
6
Target Groups
6
Warnings
6
Patents
6
Safety
7
Intended Use
7
Special Conditions for Safe Use
8
Intrinsic Safety (Ex Protection)
8
Certified Gas Measurement
10
Owner/Supervisor Responsibilities
11
Duties of the Operator
12
Safe Operation
12
Description
13
Function
13
Design of the Leak Detector
14
Probes
15
Display
18
Technical Data
21
EX Certification (Intrinsic Safety)
23
Sensors
24
Factory Settings
32
Concentration of Calibration and Test Gases
35
Getting Started
37
Charging the Battery
37
Assembling the Probe System
40
Operation
43
Switch on
43
Quick Set-Up
44
Disabling Audio Alarms in Non-Ex Modes
45
Select Available Operating Modes
45
Adjust the Local Time
45
Setting the Language
45
Activating Audio Locating Signal
46
Bluetooth Pairing Code Required
46
Change Permission Level
46
PPM Adjustment Factor
47
Select Gas (Ex)
47
100% CH4 LEL Conc
47
Set Limits and Alarm Levels
48
Select Available Modes
49
Universal Cal Setup / Abg Cal Setup
49
Universal Fnc Test Conc / Abg Fnc Test Conc
50
Set the Brightness of the Display
50
Screensaver Timeout
50
Auto-Rotate Screen
50
Configure Data Logging
50
Enable Dead Band Suppression (Irwin Sxnn Only)
51
Setting the Function Test Interval
51
Transfer Data to Computer
52
Irwin Check-In
52
Irwin Viewer
52
Paring Irwin with Computer Via Bluetooth
53
Operating Modes
53
Select Operating Mode
53
Operating Mode "Above Ground
53
Operating Modes Universal and Universal
56
Operating Mode "Bar Hole
59
Automatic "Bar Hole" Testing
60
Setting Parameters for "Auto Bar Hole
61
Operating Mode "GC Ethane Analysis
62
Operating Mode "Plants
66
Operating Mode "House
68
Operating Mode "Gas Purity
69
Operating Mode "Ex
71
Operating Mode "Ex Tox
74
Change Gas Type for %LEL Measurement
76
IR Ethane Analysis and Compensation
77
Entering Ethane Concentration Manually
78
Setting Reminder for IR Ethane Analysis
78
Performing IR Ethane Analysis after Automatic Reminder
79
Starting IR Ethane Analysis Manually
80
Viewing IR Ethane Analysis Info
80
Calibration (Adjustment)
81
Standard Calibration Procedures
84
Setting of Calibration Gas Concentrations
85
Adjust Calibration Reminder
86
Performing Function Tests
87
Measuring
89
Perform Self Test
89
Viewing Status Menu
89
Logging Data to File
90
Information
90
Retrieve Information and Statistics
90
Warnings and Error Messages
90
Viewing the Service Screen
94
Switching off
94
Maintenance
96
Maintenance Plan
96
Spare Parts List
96
General Check of Probe System
97
Maintenance of the Leak Detector
98
Seasonal Shut-Down
98
Change the Cigarette Filter in the Sample Inlet
98
Maintenance of the Hand Probe
99
Maintenance of the Carpet Probe
99
Maintenance of the Bell Probe
100
Maintenance of the Swan Neck
101
Maintenance of the Bar Hole Probe
101
Decommissioning the Leak Detector
102
Sending in the Leak Detector
102
Disposing of the Equipment
104
Safe Battery Removal
104
Declarations of Conformity
106
Index
112
Inficon 580-010 Original Operating Instructions (113 pages)
Portable Methane Leak Detector
Brand:
Inficon
| Category:
Security Sensors
| Size: 9.73 MB
Table of Contents
Table of Contents
3
1 About These Instructions
6
Target Groups
6
Warnings
6
2 Safety
7
Intended Use
7
Special Conditions for Safe Use
8
Intrinsic Safety (Ex Protection)
8
Certified Gas Measurement
8
Owner/Supervisor Responsibilities
10
Duties of the Operator
11
Safe Operation
11
3 Scope of Delivery
12
4 Description
13
Function
13
Design of the Leak Detector
14
Probes
15
Display
17
Technical Data
20
EX Certification (Intrinsic Safety)
22
Sensors
22
Factory Settings
27
Concentration of Calibration and Test Gases
29
5 Getting Started
30
Charging the Battery
30
Assembling the Probe System
33
Transfer Data to Computer
35
Install Software for Data Transfer
35
Pairing the Leak Detector with Computer Via Bluetooth Interface
35
Transfer Log Files from Leak Detector to Computer
36
Real-Time Streaming from Leak Detector to Computer
36
6 Operation
38
Switch on
38
Initial Setup
39
Adjust the Local Time
39
Setting the Language
39
Change Permission Level
39
Screensaver Timeout
40
Configure Data Logging
40
Enable Dead Band Suppression (Irwin Sxnn Only)
41
Setting the Function Test Interval
41
Calibration
41
Standard Calibration Procedures
43
Setting of Calibration Gas Concentrations
44
Adjust Calibration Reminder
45
Operating Modes
46
Select Operating Mode
46
Operating Mode "Above Ground
46
Operating Mode "Bar Hole
48
Automatic "Bar Hole" Testing
49
Setting Parameters for "Auto Bar Hole
50
Operating Mode "GC Ethane Analysis
51
Operating Mode "Confined Space
53
Operating Mode "House
55
Operating Mode "Gas Purity
56
Operating Mode "Ex
58
Operating Mode "Ex Tox
61
Change Gas Type for %LEL Measurement
63
Entering Ethane Concentration Manually
64
IR Ethane Analysis and Compensation
64
Performing IR Ethane Analysis after Automatic Reminder
65
Setting Reminder for IR Ethane Analysis
65
Starting IR Ethane Analysis Manually
66
Set Limits and Alarm Levels
67
Viewing IR Ethane Analysis Info
67
Performing Function Tests
68
Set the Brightness of the Display
68
Measuring
69
Perform Self Test
70
Viewing Status Menu
70
Logging Data to File
70
Viewing Logfile List
70
Information
71
Retrieve Information and Statistics
71
Viewing the Service Screen
71
Irwin-Operating-Instructions-Mina66En1-12
71
Activating Auto-Rotate Screen
71
Resetting to Factory Settings
72
Switching off
72
Warnings and Error Messages
72
7 Maintenance
77
Maintenance Plan
77
Spare Parts List
77
Maintenance of the Leak Detector
78
Seasonal Shut-Down
78
Change the Cigarette Filter in the Sample Inlet
78
General Check of the Probe System
78
Maintenance of the Hand Probe
80
Replace Cigarette Filter in the Hand Probe
80
Change the Inline Filter of the Carpet Probe
80
Maintenance of the Bell Probe
80
Change the Filter Discs in the Bell
80
Change the Paper Filter in the Bell
82
8 Decommissioning the Leak Detector
83
Sending in the Leak Detector
83
Disposing of the Equipment
85
9 Certificates
86
TÜV, Certificate for Lower Explosive Limit (LEL)
87
Certificate for Oxygen and Toxic Gases
91
Certificate for Software for Ex/Extox
93
ATEX Certificate for Explosion Protection (Irwin Sxnn)
94
CSA (Us/Canada) Certificate for Explosion Protection (Irwin Sxnn)
95
Iecex Certificate for Explosion Protection (Irwin Sxnn)
96
NEPSI (China) Certificate for Explosion Protection
99
CE Declaration of Conformity
105
Index
109
Advertisement
Inficon 580-010 Quick Start Manual (5 pages)
How to Set your Methane Leak Detector for 1 Point Calibration 500ppm (Universal Mode)
Brand:
Inficon
| Category:
Gas Detectors
| Size: 0.35 MB
Inficon 580-010 Quick Start Manual (2 pages)
How to enter the Ethane Compensation manually on the Methane Leak Detector
Brand:
Inficon
| Category:
Gas Detectors
| Size: 0.14 MB
Advertisement
Related Products
Inficon 580-000
Inficon 580-015
Inficon 580-020
Inficon 580-030
Inficon 580-712
Inficon 510-010
Inficon 550-330A
Inficon 550-310A
Inficon 540-200
Inficon 530-001
Inficon Categories
Security Sensors
Measuring Instruments
Controller
Test Equipment
Gas Detectors
More Inficon Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL