Sign In
Upload
Manuals
Brands
Fluidwell Manuals
Measuring Instruments
F014
Fluidwell F014 Manuals
Manuals and User Guides for Fluidwell F014. We have
2
Fluidwell F014 manuals available for free PDF download: User Manual
Fluidwell F014 User Manual (56 pages)
FLOW RATE INDICATOR / TOTALIZER WITH SCALED PULSE OUTPUT
Brand:
Fluidwell
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
2
About this Manual
4
How to Use this Manual
4
Use of Pictograms
4
Warranty and Technical Support
4
Model Reference
4
Safety
5
Personal Safety
5
End-User Responsibilities
5
Potential Equipment Damage
5
Disposal of Electronic Waste
5
Introduction
6
System Description
6
Product Features
6
General Characteristics
6
Input
7
Output
7
Options
7
Installation Example
7
Operation
8
Introduction
8
Operating Modes
8
Control Panel
8
Display
8
Backlight (Type ZB)
9
Displayed Information
9
Flow Rate and Total or Flow Rate
9
Clear Total
9
Accumulated Total
9
Operator Alarms
9
Low Battery
9
Internal Error
10
Configuration
11
Introduction
11
Configuring Using SETUP Mode
11
Entering SETUP Mode
11
Navigating the SETUP Menu
11
Changing Configuration Settings
12
Returning to Operator Mode
12
SETUP Menu Overview
13
SETUP Menu Explanations
13
Menu 1: Total
13
Menu 2: Flow Rate
14
Menu 3: Display
15
Menu 4: Power Management
16
Menu 5: Flowmeter
16
Menu 6: Pulse Output
17
Menu 7: Others
17
Installation
18
Installation / Environmental Conditions
18
Handling the F014-P Enclosure
19
Identification
19
Opening, Assembling and Closing the F-Series
20
Mechanical Installation
22
Mechanical Dimensions
22
Mounting the F-Series
24
Electrical Installation
25
Electrical Safety
25
Protective Earth (PE) Connections
25
Field Wiring Connections
26
Power Supply
27
Sensor Supply
27
Terminal Connectors Safe Area Applications - Type PX, PD
28
Terminals 1-3 (6): Flowmeter Input
28
Terminals 4-5: Power Supply - Type PX and PD
31
Terminal 6: Sensor Power Supply - Type PD
31
Terminals 7-8: Pulse Output - Type OT
31
Terminals 9-10: Backlight Power Supply - Type ZB
31
Terminal Connectors Safe Area Applications - Type PF, PM
32
Terminals GND-1-2: Power Supply
32
Terminals 3-4: Pulse Output
33
Terminals 5-7: Flowmeter Input
33
Intrinsically Safe Applications
36
Identification
36
Electrical Installation in Hazardous Areas
37
Installations Based on FM or CSA Certificate
37
Electrical Data - Control Drawing
38
Installations Based on ATEX or Iecex Certificate
39
Electrical Data - Annex 1
40
Terminal Connectors Hazardous Area Applications
41
Power Supply
41
Sensor Supply
41
Configuration Examples Intrinsically Safe Applications
42
F014-P-(OT)-PC-(PX)-XI-(ZB) Battery Powered - Ex Ia IIC/IIIC
42
F014-P-OT-PX-XI-(ZB) - Ex Ia IIC/IIIC
42
F014-P-OT-PX-XI-ZB - Ex Ia IIC/IIIC
43
F014-P-OT-PD-XI-ZB - Ex Ia IIC/IIIC
43
Maintenance
44
General Directions
44
Instructions for Repair
44
Battery Replacement
45
Safety Instructions
45
Battery Replacement Procedure
46
Disposal of Batteries
46
Appendix A - Technical Specification
47
General
47
Input
49
Output
49
Operational
49
Appendix B - Troubleshooting
50
Appendix C - Legal Information
51
Declarations of Conformity
51
Advertisement
Fluidwell F014 User Manual (56 pages)
FLOW RATE INDICATOR / TOTALIZER WITH SCALED PULSE OUTPUT, Signal input: pulse, NAMUR or coil flowmeter signal, Signal output: one scaled pulse reflecting total, Options: intrinsically safe backlight
Brand:
Fluidwell
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
2
1 About this Manual
4
How to Use this Manual
4
Use of Pictograms
4
Warranty and Technical Support
4
Model Reference
4
2 Safety
5
Personal Safety
5
End-User Responsibilities
5
Potential Equipment Damage
5
Disposal of Electronic Waste
5
3 Introduction
6
System Description
6
Product Features
6
Installation Example
7
4 Operation
8
Introduction
8
Operating Modes
8
Control Panel
8
Display
8
Backlight (Type ZB)
9
Displayed Information
9
Flow Rate and Total or Flow Rate
9
Clear Total
9
Accumulated Total
9
Operator Alarms
9
Low Battery
9
Internal Error
10
5 Configuration
11
Introduction
11
Configuring Using SETUP Mode
11
Entering SETUP Mode
11
Navigating the SETUP Menu
11
Changing Configuration Settings
12
Returning to Operator Mode
12
SETUP Menu Overview
13
SETUP Menu Explanations
13
Menu 1: Total
13
Menu 2: Flow Rate
14
Menu 3: Display
15
Menu 4: Power Management
16
Menu 5: Flowmeter
16
Menu 6: Pulse Output
17
Menu 7: Others
17
6 Installation
18
Installation / Environmental Conditions
18
Handling the F014-P Enclosure
19
Identification
19
Opening, Assembling and Closing the F-Series
20
Mechanical Installation
22
Mechanical Dimensions
22
Mounting the F-Series
24
Electrical Installation
25
Electrical Safety
25
Protective Earth (PE) Connections
25
Field Wiring Connections
26
Power Supply
27
Sensor Supply
27
Terminal Connectors Safe Area Applications - Type PX, PD
28
Terminals 1-3 (6): Flowmeter Input
28
Terminals 4-5: Power Supply - Type PX and PD
31
Terminal 6: Sensor Power Supply - Type PD
31
Terminals 7-8: Pulse Output - Type OT
31
Terminals 9-10: Backlight Power Supply - Type ZB
32
Terminal Connectors Safe Area Applications - Type PF, PM
33
Terminals GND-1-2: Power Supply
33
Terminals 3-4: Pulse Output
34
Terminals 5-7: Flowmeter Input
34
7 Intrinsically Safe Applications
37
Identification
37
Electrical Installation in Hazardous Areas
38
Installations Based on FM or CSA Certificate
38
Electrical Data - Control Drawing
39
Installations Based on ATEX or Iecex Certificate
40
Electrical Data - Annex 1
41
Power Supply
42
Sensor Supply
42
Terminal Connectors Hazardous Area Applications
42
Configuration Examples Intrinsically Safe Applications
43
F014-P-(OT)-PC-(PX)-XI-(ZB) Battery Powered - Ex Ia IIC/IIIC
43
F014-P-OT-PX-XI-(ZB) - Ex Ia IIC/IIIC
44
F014-P-OT-PD-XI-ZB - Ex Ia IIC/IIIC
45
8 Maintenance
46
General Directions
46
Instructions for Repair
46
Battery Replacement
47
Safety Instructions
47
Battery Replacement Procedure
48
Disposal of Batteries
48
Appendix A - Technical Specification
49
General
49
Input
51
Output
51
Operational
51
Appendix B - Troubleshooting
52
Appendix C - Legal Information
53
Declarations of Conformity
53
Advertisement
Related Products
Fluidwell F014-P
Fluidwell F014-A
Fluidwell F010-U
Fluidwell F012-P
Fluidwell F010-A
Fluidwell F013-P
Fluidwell F013-A
Fluidwell F011
Fluidwell F012
Fluidwell F016
Fluidwell Categories
Measuring Instruments
Controller
Monitor
Desktop
Touch Panel
More Fluidwell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL