Sign In
Upload
Manuals
Brands
fluenta Manuals
Measuring Instruments
FGM 160
fluenta FGM 160 Flare Gas Meter Manuals
Manuals and User Guides for fluenta FGM 160 Flare Gas Meter. We have
4
fluenta FGM 160 Flare Gas Meter manuals available for free PDF download: Installation Instructions Manual, User Manual, Operating Instructions Manual, Maintenance Procedures
fluenta FGM 160 Installation Instructions Manual (40 pages)
Flare Gas Meter
Brand:
fluenta
| Category:
Measuring Instruments
| Size: 1.35 MB
Table of Contents
Table of Contents
2
1 Purpose
4
2 Abbreviations / Definitions
4
Abbreviations
4
Definitions
4
3 General
5
4 Unpacking
5
Inspection of Goods
5
Ex-Classification Marking
5
Equipment Information
6
Manufacturer Information
6
5 Transducer/Probe Installation
6
Installation of Transducer Holders
6
Space Requirements
6
Figure 1: Fluenta's Minimum Straight Up- and Downstream Distances to Disturbances
7
Space Requirements for the Temperature and Pressure Transmitters
7
Space Requirements for the Transducer Full Size, TFS
7
Table 1: the Space Requirements for Transducer Full Size, TFS
7
Figure 2: Distance Requirements for the Pressure and Temperature Transmitters
8
Mounting the Transducer Holders
9
Orientation
9
Figure 3: the Preferred and Non-Preferred Orientation for Horizontal Pipe Installation
9
Horizontal Flare Pipe
9
Figure 4: Vertical Flare Boom with the Transducer Holders and Transducers Installed
10
Vertical Flare Pipe
10
Cold Tapping
11
Figure 5: Cold Tapping - Placement of Spot Marks
11
Figure 6: Cold Tapping - Centerlines
11
Figure 7: Cold Tapping - Contour Marker
11
Figure 8: Marking a Line Around the Pipe Using a Marking Band
12
Figure 9: Machined Hole
13
Figure 10: Machined Holder
13
Figure 11: as You Raise the Transducer Holder, You Must also Move It Backwards to Keep the Centering
13
Figure 12: Welding Jig and Transducer Holder
14
Figure 13: Transducer Holder Welded to the Pipe
14
Using the Sighting Tool
15
Figure 14: the Sighting Tool for the 42°/48° Transducer Holders
15
Figure 15: the Sighting Tool for 45° Transducer Holders
15
Figure 16: the Stop Washer for the Sighting Tool for the 42°/48° Transducer Holders
15
Figure 17: a 45° Sighting Tool Mounted in a Transducer Holder
15
Figure 18: a 42°/48° Sighting Tool with Stop Washer Mounted in a Transducer Holder
15
Hot Tapping Transducers Full Size, TFS
16
Figure 19: Look through the Holes on the Sighting Tool. Rotate the Sighting Tool on the Left to Get a Correct Alignment
16
Figure 20: a Good Alignment
16
Figure 21: a Bad Alignment
16
Mounting the Ultrasonic Transducers
17
Determining the Correct Position for the Transducers
17
Figure 22: the Gas-Proof Measuring Tool
17
Edge Flush Transducer Mounting
18
Figure 23: a Schematic of the Gas-Proof Measuring Tool
18
Figure 24: Insertion Depth
18
Setting the Correct Insertion Depth
18
45° Installations
19
Figure 25: Retracted Tranducers Distance
19
Figure 26: Edge-Flush Position for a 45° Transducer Holder
19
48°/42° Installations
20
Figure 27: Edge-Flush Position for a 42° Transducer Holder
20
Figure 28: Edge-Flush Position for a 48° Transducer Holder
20
Insertion of the Transducer Full Size (TFS)
21
6 Field Computer Installation
21
Figure 29: Mounting the Transducer Full Size
21
The Field Computer Mounting Frame
22
Electrical Wiring
22
Figure 30: the FGM 160 Field Computer Mounting Frame Versions
22
Cable Preparations
23
Figure 31: Ex-E Enclosure Terminals Overview
23
Figure 32: Power to the FGM 160
24
Power Cable
24
Ultrasonic Transducer Cables
24
Figure 33: Connecting the Ultrasonic Transducers to the FGM 160
25
Figure 34: Connection Details for Ultrasonic Transducers
26
Connecting the Pressure and Temperature Transmitters
27
Figure 35: Pressure and Temperature Transmitter Hook-Up
27
Figure 36: FGM 160 - 4-20 Ma Pressure and Temperature Transmitter Connections
28
Figure 37: Pressure and Temperature HART Transmitter Connection
28
Control Room and Data Cables
29
DCS Port, Modbus
29
Figure 38: Data and Signal Cables
29
Foundation Fieldbus Output
29
Current Loop Outputs (4-20Ma)
30
Figure 39: Foundation Fieldbus Connection
30
Service Port
30
Figure 40: Active Output Current Loop(S), Wiring
31
Figure 41: Passive Output Current Loop(S), Wiring
32
Figure 42: Current Loop Outputs, Details
33
Table 2: Min./Max. Loop Resistance at Typical Loop Voltages
33
Figure 43: Current Loop Outputs, Load/Voltage Limitations
34
Figure 44: Current Loop Active Output, High Side Load and Low Side Load
34
Figure 45: Current Loop Passive Output, High Side Load and Low Side Load
34
Figure 46: Multiple Current Loop Outputs, Active Output Configuration
35
Figure 47: Multiple Current Loop Outputs, Passive Output Configuration
35
HART Output
35
Pulse/Frequency/Level Output
36
Figure 48: FGM 160 Pulse/Frequency Output Connections
37
Figure 49: FGM 160 Pulse/Frequency Output Connections. Without External Power
37
Upgrading from the FGM 130
38
Figure 50: FGM 130 -> FGM 160 Upgrade
38
7 References
39
8 Appendix I - Space Requirements for the TFS
40
Figure 51: Space Requirements for the TFS
40
Advertisement
fluenta FGM 160 User Manual (34 pages)
Brand:
fluenta
| Category:
Measuring Instruments
| Size: 10.8 MB
Table of Contents
Table of Contents
3
Document Information
4
Described Product
4
Manufacturer
4
Legal Information
4
Cautions
4
Operational
4
Environmental
4
Introduction
5
Original Document
5
The Function of this Document
5
Symbols Used
5
Warning Symbols
5
Information Symbols
5
Transport
5
Product Description
6
Intended Use
6
Location for Calibration
6
What's in the Box
6
Supplied with Flarecal
6
You will also Need
6
Product Overview
7
Flarecal Calibration Box
7
Calibration Flow
8
Calibration Software
9
UFM Manager Software
9
Installing UFM Manager
9
Running UFM Manager
9
UFM Manager User Interface
10
Precalibration Procedure
11
Permit
11
USB/RS-485 Modbus Converter
11
Locate the RS-485/Modbus Connections
11
Connect the Converter to FGM 160
11
Setting up the Laptop
12
Post Connection Steps
12
Setting up the Laptop
13
Download FGM 160 Data
14
Firmware Update
15
Transducer Removal and Cleaning
17
Transducer Transportation
18
Calibration Procedure
19
Location
19
Mounting the Transducers
19
Setting the Depth of Lateral 45 Transducers
20
Setting the Depth of Bias 90 Transducers
20
Connecting the Laptop
21
Calibration Menu
22
Re-Fit the Transducers
25
Upload Calibration Data
26
Upload New Parameters to the FGM 160
26
Confirm Final FGM 160 Parameters
26
Completion of Calibration
27
Reporting
27
Validation
27
Disconnect the FGM 160
27
Close Work Permits
27
Storage
28
Replacement Parts
28
Technical Specifications
29
Recycling and Disposal
30
Warranty Statement
30
Product Certification
31
CE | EU Declaration of Conformity
31
UKCA | UK Conformity Assessed
32
Further Information
33
Definitions
33
References
33
Contact
34
fluenta FGM 160 Operating Instructions Manual (27 pages)
Flare Gas Meter
Brand:
fluenta
| Category:
Measuring Instruments
| Size: 2.68 MB
Table of Contents
Table of Contents
2
1 Purpose
3
2 Abbreviations/Definitions
3
Abbreviations
3
Definitions
3
3 General Information
3
Hardware Description
3
Electrical Connections
4
Power Supply
4
Input Signals
4
Ultrasonic Transducers
4
Pressure and Temperature Transmitters
5
Output Signals
5
Modbus Communication (RS-485)
5
Foundation Fieldbus Output
5
Current Loop Outputs
5
HART Output
5
Pulse/Frequency Output
5
Electronic Modules in FGM 160
6
Digital Signal Processing (DSP) Module
6
Analog Front End (AFE) Module
6
Pressure & Temperature (P&T) Module
6
Input/Output (I/O) Module
6
Intrinsic Safety Barrier (IS Barrier) Module
6
Surge Protection Module
6
Local Display Module
6
Non-Resettable Counter Function
7
Firmware Description
7
DSP Module
7
P&T Module
8
I/O Module
8
Device Integrity
8
Self-Checking
8
Watchdog Timer
8
Flash Memory
8
Configuration and Operating Software
9
4 Operating Procedure
10
Introduction
10
Power-Up Sequence
10
Field Computer Configuration
10
Local Display Functions
11
Error Check and Troubleshooting
12
Error Check with Local Display
12
Error Check with UFM Manager
13
5 References
13
6 Appendix I - System Configuration File
14
7 Appendix II - Inserting Settings from Client Parameter List
18
Advertisement
fluenta FGM 160 Maintenance Procedures (4 pages)
Flare Gas Meter
Brand:
fluenta
| Category:
Measuring Instruments
| Size: 0.24 MB
Advertisement
Related Products
fluenta Categories
Measuring Instruments
More fluenta Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL