Table of Contents
Marine Generator Manual
1
Current Revision Status
2
Table of Contents
3
General Instructions and Regulations
10
Safety First
10
Tools
12
Customer Registration and Guarantee
14
Technical Support
14
Caution, Important Information for Start-Up
14
Safe Operation
15
Observe Safety Instructions
15
Personal Protective Clothing (PPE)
15
Cleanliness Ensures Safety
15
Exhaust Fumes and Fire Protection
16
Protect Your Hands and Body from Rotating Parts
17
Anti-Freeze and Disposal of Fluids
17
Warning and Instruction Signs
18
Special Instructions and Hazards of Generators
18
Protective Conductor for Panda AC Generators
19
Switch off All Loads While Working on the Generator
19
Potential Equalisation for Panda AGT DC Generators
19
General Safety Instructions for Handling Batteries
20
In Case of Emergency First Aid / IM Notfall - Erste Hilfe
21
Basics
23
Intended Use of the Machine
23
Purpose of the Manual and Description of the Definitions of the Trained Persons/Operators/Users
23
Trained Persons
23
Operator/Owner
23
User
24
Components of the I-System
24
Panda Transport Box
25
Bolted Fischer Panda Transport Box
25
Fischer Panda Transport Box with Metal Tab Closure
26
Opening the GFK Sound Insulation Capsule
26
Transport and Loading/Unloading
26
Transporting the Generator
26
Loading/Unloading of the Generator
27
Special Service Instructions and Measures for Extended Machine Downtimes and Decommissioning
27
Instructions for the Starter Battery for Extended Downtimes
27
Measures for Short Downtimes
28
Measures for Medium Term Downtimes / Hibernation
28
Courses for Preservation
28
Measures for Removing Surface Protection after Medium Term Downtimes
29
Months)
29
Measures for Extended Downtimes / Decommissioning
29
Courses for Preservation
29
Measures for Removing Surface Protection after Extended Downtimes / Recommissioning (over 6 Months)
30
Panda 5000I PMS Generator
33
Type Plate at the Generator
33
Right Side View
34
Left Side View
35
Front View
36
Back View
37
Details of Function Units
38
The Panda Icontrol2 Panel
38
Components of the Cooling System
39
Components of the Fuel System
40
Components of the Electrical System
41
Components of the Oil Circuit
42
Sensors and Switches for Operating Surveillance
42
Operation Instructions - See Separate Icontrol Panel Manual
44
Daily Routine Checks before Starting - See Icontrol Manual
44
Starting Generator - See Icontrol Manual
44
Stopping the Generator - See Icontrol Manual
44
Installation Instructions
45
Personal Requirements
45
Hazard Notes for the Installation
45
Place of Installation
47
Preliminary Remark
47
Preparing the Base - Placement
47
Advice for Optimal Sound Insulation
48
Generator Connections
48
Installation of the Cooling System - Raw Water
49
General Information
49
Installation of the through Hull Fitting in Yachts - Scheme
49
Quality of the Raw Water Sucking in Line
49
Generator Installation above Waterline
50
Generator Installation below Waterline
50
Raw Water Installation Scheme
51
First Filling and Ventilation of the Internal Cooling Water Circuit
52
Anti-Freeze in the Cooling Water Circuit
53
Temperature Check for Controlling the Cooling Water Circuit
53
Installation of the Standard Exhaust System
54
Installation of the Waterlock
54
Possible Cause for Water in the Exhaust Hose
55
Possible Cause: Exhaust Hose
55
Possible Cause: Cooling Water Hose
55
Installation Area of the Waterlock
55
The Volume of the Waterlock
56
Ideal Position of the Waterlock
56
Example of the Installation of the Waterlock Off-Center and Possible Effects
58
Exhaust / Water Separator
59
Installation Exhaust Water Separator
60
Fuel System Installation
61
The Following Items Need to be Installed
61
Connection of the Fuel Lines at the Tank
62
Position of the Pre-Filter with Water Separator
63
Generator DC System Installation
64
Connection of the Starter Battery Block
64
Connection of the Remote Control Panel - See Panda Icontrol Panel Manual
67
Installation of the Icontrol Panel - See Icontrol Manual
67
Generator AC System Installation
67
Installation Pmgi Inverter - See Separate Pmgi 5000 Inverter Manual
68
Power Source Selector
68
Checking and Filling of the Oil Circuit
70
Isolation Test
70
Initial Operation
70
Maintenance Instructions
71
Personal Requirements
71
Hazard Notes for the Maintenance and Failure
71
Environmental Protection
73
General Maintenance Instructions
73
Maintenance Parts
73
Checks before each Start
74
Maintenance Interval
74
Check of Hoses and Rubber Parts in the Sound Insulated Capsule
74
Oil Change Intervals
74
Checking Oil-Level
74
Refilling Oil
75
After the Oil Level Check and Refilling the Oil
76
Replacement of Engine Oil and Engine Oil Filter
76
After the Oil Change
78
Verifying the Starter Battery and (if Necessary) the Battery Bank
78
Battery
78
Check Battery and Cable Connections
78
Exchange of the Fuel Filter
79
Aerating the Fuel System
79
Replacement of the Air Filter
80
Aerating of the Coolant Circuit / Freshwater
81
The Raw Water Circuit
81
Clean Raw Water Filter
81
Causes with Frequent Impeller Waste
81
Replacement of the Impeller
82
Generator Tables
85
Diameter of Conduits
85
Technical Data
85
Engine Oil
86
Engine Oil Classification
86
Fuel
86
Coolant Specifications
86
Coolant Mixture Ratio
87
Inverter Panda Pmgi 5000
89
Safety Instruction
90
Type Plate
90
Front Side/Connection Side
92
Socket Pins of the Pmgi 5000
93
Back Side - Top Side
94
Settings in the Victron VE Configure II Software - General
95
Uninterrupted AC Power (UPS Function)
95
Dynamic Current Limiter
95
Settings in the Victron VE Configure II Software - Inverter
96
Assist Current Boost Factor
96
Primary Remarks / Winter Operation
97
Load at the Pmgi
97
Automatic Start
97
Status Led´s
97
Cooling of the Pmgi
97
Electrical Connection
98
Connection to a System with RCD
98
Connection to a System with Isolation Control
99
Technical Data
99
General Data
99
Generator Spezification
99
Overload - Switch Point
101
Short Circiut
101
Panda Icontrol2
103
Current Revision Status
104
Hardware
104
Safety Instructions for the Panda Icontrol2
105
Personnel
105
Safety Instructions
105
General Operation
107
The Panda Icontrol2 Panel
107
Starting Preparation / Checks (Daily)
108
Marine Version
108
Vehicle Version
108
Operation
109
Switching the Controller on and off
109
The Default Display Screen
109
Operating Modes
110
Stand-By Mode
110
Start-Up Mode
111
Override Mode
112
Operation Mode
112
Panda I-Generator with Electro-Magnet Clutch (Optional)
114
Autostart Mode
115
Set-Up Menu
117
The Configuration Menu ("Config")
119
The Network ID
119
Saving Settings and Exiting the Set-Up Menu ("Save & Exit")
119
Activating/Deactivating the Autostart Function ("Autostart")
119
Resetting the Service Interval ("Service")
121
Priming the Fuel System ("Prime Fuel")
122
Selecting and Saving a Unit for the Temperature Value Output
122
Installation
125
Personnel
125
Hazard Warnings for Installation
125
Disposal of the Components
126
Panda Icontrol2 Panel with Installation Housing
127
Terminal Assignments on the Panda Icontrol2 Panel
127
Dimensions
128
Wiring of the Panda Icontrol2 Controller
129
Terminal Assignments on the Panda Icontrol2 Controller
130
Terminal Assignment of 18-Pin Connector
130
Fischer Panda Standard Bus
130
Fischer Panda CAN Bus
130
Master and Slave Panels
131
Maintenance
133
Maintenance of the Icontrol2 Controller
133
Cleaning the Icontrol2 Controller
133
Maintenance of the Icontrol2 Remote Control Panel
133
Annex
135
Technical Data
135
Technical Data for Icontrol2 Control Unit
135
Technical Data for Icontrol2 Remote Control Panel
135
Warnings and Error Messages
137
Warnings
137
Examples of Warnings on the Display
137
Faults
138
Warning and Fault Thresholds
139
Bus Errors
141
The Error Memory of the Icontrol 2 Panel
141
How to Get to the Error Memory of the Icontrol2 Panel
141
How Are Stored Errors Displayed
141
How Do I Exit the Error Memory after Having Read the Entries
142
Can I Delete the Error Memory
142
Where Are the Errors Stored
142
In Which Language Are the Stored Errors Displayed
142
Is It Possible to Upgrade an Old Igenerator Model by the Error Memory
142
Advertisement
Advertisement
Related Products
Fischer Panda Panda 5000i PMS
Fischer Panda 5000i PVK-U
Fischer Panda 55-4 PSC
Fischer Panda PMS 9000ND
Fischer Panda PMS 5000 LPE
Fischer Panda PMS-HD 30-4MI
Fischer Panda Panda AGT-DC 5000 PMS
Fischer Panda Panda 5K PMS
Fischer Panda 0032820
Fischer Panda 0032821
Fischer Panda Categories
Portable Generator
Inverter
Controller
Control Panel
Control Systems
More Fischer Panda Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL