Sign In
Upload
Manuals
Brands
Daikin Manuals
Air Conditioner
VRV 5-S Series
Daikin VRV 5-S Series Manuals
Manuals and User Guides for Daikin VRV 5-S Series. We have
2
Daikin VRV 5-S Series manuals available for free PDF download: Installer And User Reference Manual, Installation And Operation Manual
Daikin VRV 5-S Series Installer And User Reference Manual (164 pages)
Brand:
Daikin
| Category:
Air Conditioner
| Size: 11.49 MB
Table of Contents
Table of Contents
2
1 About the Documentation
6
About this Document
6
2 General Safety Precautions
7
About the Documentation
7
Meaning of Warnings and Symbols
7
For the Installer
8
General
8
Installation Site
9
Refrigerant
9
Brine
11
Water
12
Electrical
12
3 Specific Installer Safety Instructions
14
Instructions for Equipment Using R32 Refrigerant
17
Installation Space Requirements
18
System Layout Requirements
19
To Determine the Charge Limitations
23
For the User
28
4 User Safety Instructions
29
General
29
Instructions for Safe Operation
30
5 About the System
32
System Layout
32
6 User Interface
33
7 Before Operation
34
8 Operation
35
Operation Range
35
Operating the System
35
About Operating the System
35
About Cooling, Heating, Fan Only, and Automatic Operation
35
About the Heating Operation
35
To Operate the System (WITHOUT Cool/Heat Changeover Remote Control Switch)
36
To Operate the System (with Cool/Heat Changeover Remote Control Switch)
36
Using the Dry Program
38
About the Dry Program
38
To Use the Dry Program (WITHOUT Cool/Heat Changeover Remote Control Switch)
38
To Use the Dry Program (with Cool/Heat Changeover Remote Control Switch)
38
Adjusting the Air Flow Direction
40
About the Air Flow Flap
40
Setting the Master User Interface
41
About Setting the Master User Interface
41
To Designate the Master User Interface
41
9 Energy Saving and Optimum Operation
42
Available Main Operation Methods
43
Available Comfort Settings
43
10 Maintenance and Service
44
Maintenance after a Long Stop Period
44
Maintenance before a Long Stop Period
45
About the Refrigerant
45
After-Sales Service and Warranty
46
Warranty Period
46
Recommended Maintenance and Inspection
46
Recommended Maintenance and Inspection Cycles
46
Shortened Maintenance and Replacement Cycles
47
11 Troubleshooting
49
Error Codes: Overview
51
Symptoms that Are NOT System Malfunctions
53
Symptom: the System Does Not Operate
53
Symptom: Cool/Heat Cannot be Changed over
53
Symptom: Fan Operation Is Possible, but Cooling and Heating Do Not Work
53
Symptom: the Fan Speed Does Not Correspond to the Setting
53
Symptom: the Fan Direction Does Not Correspond to the Setting
53
Symptom: White Mist Comes out of a Unit (Indoor Unit)
54
Symptom: White Mist Comes out of a Unit (Indoor Unit, Outdoor Unit)
54
Symptom: the User Interface Reads "U4" or "U5" and Stops, but then Restarts after a few Minutes
54
Symptom: Noise of Air Conditioners (Indoor Unit)
54
Symptom: Noise of Air Conditioners (Indoor Unit, Outdoor Unit)
54
Symptom: Noise of Air Conditioners (Outdoor Unit)
54
Symptom: Dust Comes out of the Unit
55
Symptom: the Units Can Give off Odours
55
Symptom: the Outdoor Unit Fan Does Not Spin
55
Symptom: the Compressor in the Outdoor Unit Does Not Stop after a Short Heating Operation
55
Symptom: the Inside of an Outdoor Unit Is Warm Even When the Unit Has Stopped
55
Symptom: Hot Air Can be Felt When the Indoor Unit Is Stopped
55
12 Relocation
56
13 Disposal
57
14 Technical Data
58
Information Requirements for Eco Design
58
For the Installer
59
15 About the Box
60
Overview: about the Box
60
Outdoor Unit
61
To Unpack the Outdoor Unit
61
To Handle the Outdoor Unit
61
To Remove the Accessories from the Outdoor Unit
62
16 About the Units and Options
63
Overview: about the Units and Options
63
Identification
64
Identification Label: Outdoor Unit
64
About the Outdoor Unit
64
System Layout
65
Combining Units and Options
65
About Combining Units and Options
65
Possible Combinations of Indoor Units
65
Possible Options for the Outdoor Unit
66
17 Unit Installation
67
Preparing the Installation Site
67
Installation Site Requirements of the Outdoor Unit
67
Additional Installation Site Requirements of the Outdoor Unit in Cold Climates
70
Opening and Closing the Unit
71
About Opening the Units
71
To Open the Outdoor Unit
71
To Close the Outdoor Unit
71
Mounting the Outdoor Unit
73
About Mounting the Outdoor Unit
73
Precautions When Mounting the Outdoor Unit
73
To Provide the Installation Structure
73
To Install the Outdoor Unit
74
To Provide Drainage
74
To Prevent the Outdoor Unit from Falling over
75
18 Piping Installation
77
Preparing Refrigerant Piping
77
Refrigerant Piping Requirements
77
Refrigerant Piping Material
77
To Select the Piping Size
78
To Select Refrigerant Branch Kits
79
Refrigerant Piping Length and Height Difference
80
Connecting the Refrigerant Piping
81
About Connecting the Refrigerant Piping
81
Precautions When Connecting the Refrigerant Piping
81
Pipe Bending Guidelines
82
To Braze the Pipe End
82
Using the Stop Valve and Service Port
83
To Remove the Spun Pipes
84
To Connect the Refrigerant Piping to the Outdoor Unit
85
To Connect the Refrigerant Branching Kit
87
Checking the Refrigerant Piping
88
About Checking the Refrigerant Piping
88
Checking Refrigerant Piping: General Guidelines
89
Checking Refrigerant Piping: Setup
89
To Perform a Leak Test
90
To Perform Vacuum Drying
90
19 Charging Refrigerant
92
About Charging Refrigerant
92
About the Refrigerant
93
Precautions When Charging Refrigerant
94
To Determine the Additional Refrigerant Amount
96
To Charge Refrigerant
97
Error Codes When Charging Refrigerant
99
To Fix the Fluorinated Greenhouse Gases Label
99
To Check for Refrigerant Leaks after Charging
100
20 Electrical Installation
101
About Connecting the Electrical Wiring
101
Precautions When Connecting the Electrical Wiring
101
Field Wiring: Overview
102
Guidelines When Knocking out Knockout Holes
104
Guidelines When Connecting the Electrical Wiring
104
About Electrical Compliance
105
Safety Device Requirements
106
To Connect the Electrical Wiring to the Outdoor Unit
107
To Connect the External Outputs
110
21 Finishing the Outdoor Unit Installation
112
To Insulate the Refrigerant Piping
112
To Close the Outdoor Unit
115
To Check the Insulation Resistance of the Compressor
115
22 Configuration
116
Overview: Configuration
116
Making Field Settings
117
About Making Field Settings
117
To Access the Field Setting Components
118
Field Setting Components
118
To Access Mode 1 or 2
118
To Access Mode 1 or 2
119
To Use Mode 1
120
To Use Mode 2
121
Mode 1: Monitoring Settings
122
Mode 2: Field Settings
123
Energy Saving and Optimum Operation
129
Available Main Operation Methods
129
Available Comfort Settings
130
Example: Automatic Mode During Cooling
132
Example: Automatic Mode During Heating
133
23 Commissioning
135
Precautions When Commissioning
135
Checklist before Commissioning
136
Checklist During Commissioning
137
About the Test Run
137
To Perform a Test Run (7-Segments Display)
137
Correcting after Abnormal Completion of the Test Run
138
24 Hand-Over to the User
139
25 Maintenance and Service
140
Overview: Maintenance and Service
140
Maintenance Safety Precautions
141
To Prevent Electrical Hazards
141
Checklist for Yearly Maintenance of the Outdoor Unit
142
About Service Mode Operation
142
To Use Vacuum Mode
142
To Recover Refrigerant
143
26 Troubleshooting
144
Overview: Troubleshooting
144
Precautions When Troubleshooting
145
Solving Problems Based on Error Codes
145
Error Codes: Overview
145
Refrigerant Leak Detection System
149
27 Disposal
151
28 Technical Data
152
Service Space: Outdoor Unit
153
Piping Diagram: Outdoor Unit
155
Wiring Diagram: Outdoor Unit
156
29 Glossary
160
Advertisement
Daikin VRV 5-S Series Installation And Operation Manual (48 pages)
Brand:
Daikin
| Category:
Air Conditioner
| Size: 9.69 MB
Table of Contents
Table of Contents
7
Configuration
34
Making Field Settings
34
About Making Field Settings
34
To Access the Field Setting Components
35
Field Setting Components
35
To Access Mode 1 or 2
36
To Use Mode 1
36
To Use Mode 2
36
Mode 1: Monitoring Settings
36
Mode 2: Field Settings
37
Commissioning
37
Precautions When Commissioning
37
Checklist before Commissioning
37
Checklist During Commissioning
38
About the Test Run
38
To Perform a Test Run (7-Segments Display)
38
Correcting after Abnormal Completion of the Test Run
39
Troubleshooting
39
Solving Problems Based on Error Codes
39
Error Codes: Overview
39
Refrigerant Leak Detection System
40
Technical Data
42
Service Space: Outdoor Unit
42
Piping Diagram: Outdoor Unit
43
Wiring Diagram: Outdoor Unit
44
Advertisement
Related Products
Daikin vrv III -Q Series
Daikin VRVII
Daikin VRVII-S
Daikin VRV-WII Series
Daikin VRV4 XKQ-M
Daikin VRV4 FXSQ-P
Daikin VRV4 FXDQ-M
Daikin VRV4 FXMQ-P
Daikin VRVII Series
Daikin VRV III RXYQ72PBTJ
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL