Sign In
Upload
Manuals
Brands
Burster Manuals
Measuring Instruments
DIGIFORCE 9311
Burster DIGIFORCE 9311 Manuals
Manuals and User Guides for Burster DIGIFORCE 9311. We have
5
Burster DIGIFORCE 9311 manuals available for free PDF download: Operation Manual
Burster DIGIFORCE 9311 Operation Manual (274 pages)
Brand:
Burster
| Category:
Recording Equipment
| Size: 1.97 MB
Table of Contents
Table of Contents
3
1 For Your Safety
10
Symbols Used in the Instruction Manual
10
Signal Words
10
Pictograms
10
Symbols and Precautionary Statements on the Instrument
11
2 Introduction
12
General Safety Instructions
12
Intended Use
13
Electromagnetic Compatibility
13
Interference Immunity
13
Emitted Interference
13
Notes on CE Labeling
13
3 General Communication Info
14
Communication Via the USB Port
14
The Communications Protocol
15
Establishing a Connection
15
Selection with Response
16
Fast Selection
18
Polling
19
Data Transfer
19
Timers
20
Terminating a Connection
20
Communication Via the Ethernet Port
21
The UDP Transmission Protocol
21
4 Commands
25
Device Status
27
FSTA - 9311 Query Device Status
27
General Commands
29
GOTO - Go to Measurement or Setup Menu
29
UPDA - Perform Display Update
29
MEFR - Enable Start of Measurement ON/OFF
30
EIZA - Query or Reset Power up Counter
31
EIGE - Query or Reset Counter Setting Changed
31
Minimum Setup Menu
33
PRNR - Select Measurement Program
33
PNAM - Enter or Query the Name of the Measurement Program
33
RSPR - Reset Measurement Program Statistics
35
RSET - Reset All Measurement Program Statistics
35
CMPR - Checks the Measurement Program Names
36
Assigning Function Keys
37
FKEY - Set or Query Function Key Assignments
37
FKAU - Always Hide or Show Function Keys
38
PLC Outputs/Inputs
39
SPSA - Set Selectable PLC Output Assignments
39
PCLO - Set or Reset the PLC Output Signal OUT_PC_LOGGING
40
SPIC - Set Selectable PLC Input Assignments
41
Access Permissions
42
MPAS - Enter or Query Master Password
42
MRES - Reset Master Password to Default
43
UPAS - Enter or Query User Password
43
PASP - Query or Enable/Disable Password Protection
44
ZUGR - Enable/Lock or Query Access Levels
44
Enabling Measurement Menus
46
MFRE - Measurement Menu Enable
46
Info Menu
47
INFO - Device Info Query
47
SERN - Serial Number
48
STAN - Station Name
48
LCD Setting
49
LCDK - Set LCD Contrast
49
Date and Time
50
DATE - Set or Query Date
50
TIME - Set or Query the Time of Day
50
User Languages
51
SPRA - Set or Query User Language
51
Acknowledgement Function
52
AMPL - ACK Function ON/OFF
52
Quio - Ok Ack On/Off
52
Qnio - Nok Ack On/Off
53
LASU - Buzzer Volume
54
Fieldbusses
55
FELD - Which Fieldbus Is Implemented on the NETX Circuit Board
55
PBIN - Device Controlled Via Fieldbus or PLC
55
PROFIBUS Settings
56
PBAD - Set PROFIBUS Address
56
PINF - PROFIBUS Info
57
Ethercat Settings
57
EINF - Ethercat Info
57
PROFINET Settings
58
PNIF - PROFINET Info
58
FBKS - Enter and Query the Fieldbus Board Serial Number
58
FBMA - Enter and Query the Fieldbus Board MAC Addresses
59
Board Flash Memory
59
FMAC - Checks Whether the MAC Addresses Have Been Programmed in the Fieldbus Board Flash Memory
60
Ethernet/Ip Settings
61
ETHI - Ethernet/Ip Settings
61
Order Sheet
62
AUWE - Order Sheet: Operator
62
AUNR - Order Sheet: Order Number
62
AUCH - Order Sheet: Batch
63
AUBA - Order Sheet: Component Identification
64
AUS1 - Order Sheet Serial Number 1
64
AUS2 - Order Sheet Serial Number 2
65
Measurement Mode
66
ABTX - X Sampling ON/OFF
66
ABTY - y Sampling ON/OFF
67
ABTZ - Time Sampling ON/OFF
69
ABSX - Set or Query X Sample Rate
70
ABSY - Set or Query y Sample Rate
72
ABSZ - Set or Query Time Sample Rate
73
BZUG - Set or Query Reference
75
BEZY - Set or Query Reference Line y
77
TRIY - Set or Query Trigger Line y
78
UPKT - Set or Query Return Point
80
KERF - Set or Query 'Record Curve to
81
STAM - Set or Query Start Mode
83
STOM - Set or Query Stop Mode
85
STAX - Set or Query Start Value X
87
STAY - Set or Query Start Value y
88
STOX - Set or Query X Stop Value
89
STOY - Set or Query y Stop Value
91
STOT - Set or Query Stop Timeout Value
92
STOA - Set or Query Number of Readings Stop Mode
94
Channel Settings
95
KAGL - Channel Settings Global or Program Dependent
95
KANA - Set Channels (Connection, Sensor)
96
FILT - Set or Query Filters
99
EINH - Select or Query Unit
102
BEIN - Set or Query User Defined Units
105
SKAL - Scaling; Receive and Implement Values
106
MKAL - Teach in Cal Values
108
TABM - Set or Query Tare at Start of Measurement
109
TAVO - Set or Query Tare Default
111
TAWA - Set or Query Tare Warning
112
TAWG - Set or Query Tare Warning Limit
114
TARA - Perform Tare
116
TAWE - Set or Query Tare Value
117
Standard Signal Input
118
NOEI - Set or Query Standard Signal Input Range
118
Strain Gauge Sensor
120
NOEI - Set or Query Strain Gauge Input Range
120
DMNK - Set or Query Strain Gauge Sensitivity
122
DMAS - Query Strain Gauge Output Level
124
Piezo Sensor
125
PIEI - Set or Query Piezo Input Range
125
PIKZ - Open/Close Piezo Input Short Circuit
127
Evaluating the Square Window
128
FEST - Switch ON/OFF Square Window
128
FGRZ - Set or Query Square Window Limits
129
FEAU - Set or Query Square Window Entry and Exit Sides
131
FKAB - Curve Section over Which a Square Window Is Evaluated
134
FOBE - Set Online Evaluation for a Square Window
136
FOLV - Set Online Signal Level for a Square Window
137
FBEF - Evaluation Result of a Square Window (OK/NOK)
139
FNIO - Number of Noks for a Square Window
140
FMAA - Query the Absolute Maximum Within a Square Window
141
FMIA - Query the Absolute Minimum Within a Square Window
142
FEIN - Query the Curve Entry Values of a Square Window
143
FAUS - Query the Curve Exit Values of a Square Window
145
Evaluating Thresholds
146
SWST - Thresholds ON/OFF
146
STYP - Set Threshold Type (X/Y Threshold)
147
SGRZ - Set or Query Threshold Limits
149
SDUR - Set or Query Threshold Crossover
151
SKAB - Curve Section over Which a Threshold Is Evaluated
153
SBEF - Evaluation Result of a Threshold (OK/NOK)
155
SNIO - NOK Counter for a Threshold
156
SDKO - the Curve's Crossover Points through a Threshold
157
Evaluating the Trapezoid Window
158
TRST - Trapezoid Window ON/OFF
158
TTYP - Set Trapezoid Type (X/Y Trapezoid Window)
159
TRGR - Enter or Query Trapezoid Window Limits
161
TREA - Enter or Query Trapezoid Window Entries/Exits
165
TRKA - Set or Query Curve Section Used to Evaluate a Trapezoid Window
168
TRBF - Evaluation Result of a Trapezoid Window (OK/NOK)
170
TRNI - Query NOK Counter for a Trapezoid Window
171
TREI - Query the Curve Entry Values of a Trapezoid Window
172
TRAU - Query the Curve Exit Values of a Trapezoid Window
173
Evaluating Envelopes
174
HKST - Envelopes ON/OFF
174
HKGR - Set or Query Start and End Values for Envelopes
176
HKDE - Set or Query Delta Min and Max Values of Envelopes
177
HKES - Set or Query the Entry Side of Envelopes
179
HKKA - Set or Query the Curve Section for Envelopes
181
HKBF - Evaluation Result of an Envelope (OK/NOK)
182
HKNI - Query NOK for an Envelope
183
HKEI - Query the Curve Entry Values of an Envelope
184
HKAU - Query the Curve Exit Values of an Envelope
185
HRAW - Index of the Last Point on the Envelope Reference Curve
186
HKGE - Generate Envelope
188
HKRX - the Reference Curve X Coordinates for Generating the Envelope
189
HRYM - the y Coordinates of the Reference Curve Mean Values for Generating the Envelope
192
HDMI - the y Coordinates of the Reference Curve Delta Min Values for Generating the Envelope
195
HDMA - the y Coordinates of the Reference Curve Delta Max Values for Generating the Envelope
198
HKDA Query: Are There Envelopes at All
201
Evaluation in General
202
TOBA - Enter or Query Tolerance Bands
202
Switching Points
203
SCHA - Configure or Query Switching Points
203
Sensor Test
206
STST - Sensor Test ON/OFF
206
STRW - Set or Query Sensor Test Reference Value
207
STAB - Set or Query Permitted Sensor Test Tolerance
209
STME - Teach in Sensor Test Reference Value
211
STDO - Perform a Sensor Test
211
User-Defined Values
212
FRDW - Enter or Query User Definable Values
212
Operand Table
213
LIVE - Set the Live Values
216
Initializing and Copying Measurement Programs
217
PRKO - Copy All Data between Measurement Programs
217
SEKO - Copy Sensor Data between Measurement Programs
217
INIT - Default Initialization of Measurement Programs
218
GINI - Default Initialization of All Measurement Programs and Device Parameters
218
Numerical Configuration
218
TEST - Switch on Test Mode for Numerical Configuration
219
TESA - Switching Signals ON/OFF in Test Mode
219
MESS - Fetch Current Readings
220
SPSI - Fetch PLC Inputs
221
SPSO - Set PLC Outputs
221
Record Errors/Events in the Logfile
223
LOGS - Port Operation Logging ON/OFF
223
LOGL - Delete Logfile, Query Index of Last Entry
223
LOGD - Query Logfile Entries
224
Voltage Monitor
226
UKNO - Measure and Test Node Voltage
226
UGND - Measure and Test GND Potential
226
USPA - Measure and Test Channel a Excitation
227
USPB - Measure and Test Channel B Excitation
227
Amplifier Test
228
VTKA - Channel a Amplifier Test
228
VTKB - Channel B Amplifier Test
229
Measurement Results
231
MSTA - Measurement Status; Is There a New Measurement Curve
231
KRVA - Supplementary Data for Current Measurement Curve
232
MEVE - Measurement Curves
234
ALKU - General Curve Data
236
FRER - Query Measurement Results of the User Definable Values
237
FRAL - Query Measurement Results of All User Definable Values
239
RDYM - PC Ready Mode ON/OFF
240
REDY - Ready Signal Enable if Ready Mode on
241
KSAN - Query Number of Curves in the Curve Array
241
KUSA - Query Return Point and Last Value of the Curves in the Curve Array
242
KURX - Read out the X Coordinates of the Current Measurement Curve
243
KURY - Read out the y Coordinates of the Current Measurement Curve
245
KUSX - Read out the X Coordinates of a Measurement Curve from the Curve Array
247
KUSY - Read out the y Coordinates of a Measurement Curve from the Curve Array
248
MENU - Enter or Query Current Measurement Menu
250
Measurement Data Logger
252
DSTA - Query Status Information of Measurement Data Logger
252
DADA - Query General Data for a Measurement Data Logger Record
253
DRFE - Query Square Window Data for a Measurement Data Logger Record
254
DTRF - Query Trapezoid Window Data for a Measurement Data Logger Record
254
DTRF - Query Envelope Data for a Measurement Data Logger Record
255
DSCH - Query Threshold Data for a Measurement Data Logger Record
256
DXKO - Read the X Coordinates of a Measurement Curve from the Data Logger
256
DYKO - Read the y Coordinates of a Measurement Curve from the Data Logger
258
Graphical Scaling
259
ASKA - Enter or Query Autoscaling
259
MSKA - Enter or Query Manual Scaling
260
Reference Curve
262
RFAN - Show/Hide Reference Curve
262
RANZ - Number of Value Pairs for Reference Curve
263
REFX - the X Coordinates of the Reference Curve from Channel X
265
REFY - the y Coordinates of the Reference Curve from Channel y
268
Saving to USB Stick
271
USPR - USB Stick Logging ON/OFF
271
USBE - Derived File Names on USB Stick
272
USFO - Format the USB Stick Connected to the Device
273
USST - Read out USB Stick Status
273
URDY - USB Ready Control ON/OFF
274
Advertisement
Burster DIGIFORCE 9311 Operation Manual (216 pages)
Brand:
Burster
| Category:
Measuring Instruments
| Size: 16.52 MB
Table of Contents
Table of Contents
4
1 For Your Safety
9
Symbols Used in the Instruction Manual
9
Signal Words
9
Pictograms
10
Symbols and Precautionary Statements on the Instrument
10
Conventions Used in the Instruction Manual
10
2 Introduction
11
Intended Use
11
Customer Service
11
Customer Service Department
11
Contact Person
11
Download the Test Certificate
11
Ambient Conditions
12
Storage Conditions
12
Operating Conditions
12
Restrictions on Use
12
Cleaning
13
Personnel
13
Contents of Pack
13
Unpacking
14
Warranty
14
Conversions and Modifications
14
Error Messages When the Unit Is Powered up
15
3 Principles of Design and Operation
16
Range of Functions
16
Versions
16
Power Supply
17
Sensors Suitable for Use with the Instrument
17
Automatic Sensor Identification (Burster TEDS)
18
Recording Measurement Curves
18
Starting / Stopping a Measurement
18
Sampling the Measurement Signals
19
Defining an X-Axis Reference
19
Evaluation Methods
20
Tare Function
20
Sensor Test
21
Online Switching Points
21
Visualizing, Signalling and Transferring Results
21
Configuration Tools
22
4 Controls and Connections
23
Front Panel
23
Rear of Instrument
24
Touch Control
25
Controls and Symbols
26
Earthing and Shielding
27
Connections
28
PLC I/O Signals
28
Connector a - Potentiometer, Standard Signal
30
Connector A: Connecting Potentiometric Sensors
31
Connector A: Connecting Potentiometric Sensors Fitted with Burster TEDS
31
Connector A: Connecting Standard-Signal Sensors
31
Connector A: Connecting Standard-Signal Sensors Fitted with Burster TEDS
32
Connector B - Strain Gage Sensors, Standard-Signal Sensors
33
Connector B: Connecting Strain Gage Sensors Without Sense Leads
34
Connector B: Connecting Strain Gage Sensors Without Sense Leads, Fitted with Burster TEDS
34
Connector B: Connecting Strain Gage Sensors with Sense Leads
34
Connector B: Connecting Strain Gage Sensors with Sense Leads, Fitted with Burster TEDS
35
Connector B: Connecting Standard-Signal Sensors
35
Connector B: Connecting Standard-Signal Sensors Fitted with Burster TEDS
35
Connector B: Connecting a Piezoelectric Sensor (Option)
36
USB Service Port
37
Ethernet Port
37
USB Host Port (Memory-Stick Data Logging)
37
PROFIBUS Interface
38
Ethernet-Based Fieldbus Interface (Dual RJ45)
38
Instrument Power Plug
38
5 Using the Instrument for the First Time
39
Panel-Mounting
39
Panel Cutout
40
User Language and Diagnostics
41
6 Configuring the Instrument - "Configuration Main Menu
42
Basic Setup
43
Function Key Definition
44
PLC Outputs
46
PLC Inputs
48
Access Permissions
49
Measurement Menus
51
Instrument Information
52
LCD Setting
52
Date and Time
53
Language
53
Interfaces
54
USB Interface Parameters
54
Ethernet Interface Parameters
55
Acknowledgement Function
56
Order Sheet
57
USB Flash
57
Channel Settings
62
Diagnostics
63
PROFIBUS Settings (Option)
64
PROFINET Settings (Option)
65
Ethernet/Ip Settings (Option)
67
Program Selection
69
Program Setup Menu
70
Channel Settings
71
Scaling Analog Sensors (Strain Gage, Potentiometer, Standard Signal Sensors)
72
Inverting Measurement Signals
73
Configuring Sensors Fitted with Burster TEDS
73
Potentiometric Sensors
74
Sensors that Output a Standard Signal
83
Strain Gage Sensors
92
Piezoelectric Sensors (Option)
101
Measurement Mode
106
Sampling the Measurement Channels
107
Measurement Curve Reference
107
Curve Recording, Return Point
112
Start/Stop Mode
113
Configuring the Evaluation
115
Window
115
Trapezoid
120
Threshold
124
Envelopes
128
Tolerance Band for Evaluation Elements
130
Online Switching Points
132
Graphical Test Operation
134
Graphical Test Operation - Zoom (Adjust Zoom for X/Y Graphs)
136
Graphical Test Operation - Autoset
138
Graphical Test Operation - Configuring a Window
140
Graphical Test Operation - Configuring a Trapezoid
145
Graphical Test Operation - Configuring a Threshold
150
Graphical Test Operation - Generating an Envelope
155
Graphical Test Operation - Cursor
159
Graphical Test Operation - Reference Curve
161
Graphical Test Operation - Displaying a Curve Array
163
Numerical Test Operation
165
Numerical Test Operation - Live Sensor Values
166
Numerical Test Operation - Tare
168
Numerical Test Operation - PLC Signals
169
Sensor Test
171
User-Defined Values
173
USB Flash
176
Copy Programs
177
Copying a Measurement Program or Sensor Settings
177
Deleting a Measurement Program
179
Curve Analysis (Viewer)
180
Curve Analysis - Selection
182
Curve Analysis - Zoom
183
Curve Analysis - Numerical
184
7 Measurement Results Display - Measurement Mode
186
Top-Level View of Measurement Results
186
Global Header
187
Status/Error Indicator in Measurement Mode
187
Overall Result of Last Measurement
188
Individual Evaluation Status in Measurement Mode
188
M1 Graphical Measurement Curve
189
M2 General Curve Data
190
M3 Total Result
191
M4 Entry/Exit
192
M5 User Defined Values
192
M6 Statistics
193
M7 Order Sheet
194
8 Signal Timing Diagrams
195
Selecting a Measurement Program
195
Changing the Measurement Program Without Program Acknowledgement
195
Changing the Measurement Program with Program Acknowledgement
196
Starting a Measurement
197
Measurement Without Measurement-Data Logging
197
Measurement with Measurement-Data Logging
198
Measurement Using Data Logging on USB Stick (READY Control Enabled)
199
External Tare
200
Without Tare Warning
200
With Tare Warning
201
Online Signals
202
Window Evaluation with Online Signal
202
Online Switching Signals S1 to S6
203
Switching Signals for X-Channel with "Absolute" Reference
203
Switching Signals for X-Channel with "Trigger" Reference
204
Switching Signals for Y-Channel
205
Acknowledgement Function
206
Example of an NOK Evaluation for the Following Configuration
206
Example of an NOK Evaluation (Without Acknowledgement)
207
Example of an OK Evaluation (Without Acknowledgement)
208
External Actuation of a Statistics Reset
209
External Actuation of a Sensor Test
210
9 Customer Services for Your DIGIFORCE ® 9311
211
10 Technical Data
212
Electromagnetic Compatibility
212
Interference Immunity
212
Interference Emission
212
11 Accessories Available
213
Software
213
12 Disposal
214
13 Index
215
Burster DIGIFORCE 9311 Operation Manual (154 pages)
instrument for monitoring repetitive production processes
Brand:
Burster
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Changes
2
Table of Contents
4
1 Revision History
9
2 For Your Safety
10
Symbols Used in the Instruction Manual
10
Signal Words
10
Pictograms
10
Symbols and Precautionary Statements on the Instrument
11
Abbreviations
11
3 Introduction
12
General Safety Instructions
12
Intended Use
13
4 Technical Data
14
Supported PROFINET-Functions
14
Model 9307 Device Data
14
Electrical Safety
14
Electromagnetic Compatibility
15
Interference Immunity
15
Emitted Interference
15
Notes on CE Labeling
15
5 Installation
16
Connection of Fieldbus Lines
16
Meaning of LED States
16
Port-Identification
16
Configuration of a PROFINET Network
17
Configuration Menu in DIGIFORCE ® 9307
18
6 Profinet
20
General Information on PROFINET Data Transfer
20
GSD File
20
Data Conversion
21
Description of the Data Formats in this Manual
21
Handling Problems that Arise When Reading Floating-Point Numbers
21
7 Alarms
22
8 PROFINET Data Protocol
23
Meaning of the Content of the Cyclic Data Packet from Device to the Controller
23
PLC Inputs - Transfer from Controller to Device
23
PLC Inputs Byte 1 (Controller to Device)
24
PLC Inputs Byte 2 (Controller to Device)
24
PLC Inputs Byte 3 (Controller to Device)
25
PLC Inputs Byte 4 (Controller to Device)
25
PLC Outputs - Transfer from Device to Controller
26
PLC Outputs Byte 1
26
PLC Outputs Byte 2 (9307 Adjustable Outputs)
26
PLC Outputs Byte 3 (9307 Adjustable Outputs)
27
PLC Outputs Byte 4 (9307 Adjustable Outputs)
27
Default Assignment of Output Byte [4..2] Adjustable Outputs
28
Evaluation Info
29
Evaluation Info Byte 1
29
Evaluation Info Byte 2
29
Evaluation Info Byte 3
30
Evaluation Info Byte 4
30
Byte Reference List
31
9 Acyclic PROFINET Services
37
Instrument Configuration
37
General Settings (Slot 30)
37
Communication: Change Menu, Display Update, Fault Indication (Slot 32)
46
Minimal Setup Menu (Slot 33)
47
General Channel Settings (Slot 34)
47
Channel Settings "Potentiometer" (Slot 35)
52
Channel Settings "Standard Signal" (Slot 36)
53
Channel Settings "Strain Gauge" (Slot 37)
53
Channel Settings "Resistance" (Slot 38)
55
Channel Settings "Piezo" (Slot 39)
55
Channel Settings "Incremental" (Slot 40)
56
Channel Settings "SSI" (Slot 41)
58
Channel Settings "Endat" (Slot 42)
64
Tare (Slot 43)
72
Measurement Mode (Slot 44)
73
Evaluation Window 1 (Slot 45)
75
Evaluation Window 2 (Slot 46)
78
Evaluation Window 3 (Slot 47)
78
Evaluation Window 4 (Slot 48)
78
Evaluation Window 5 (Slot 49)
78
Evaluation Window 6 (Slot 50)
78
Evaluation Window 7 (Slot 51)
79
Evaluation Window 8 (Slot 52)
79
Evaluation Window 9 (Slot 53)
79
Evaluation Window 10 (Slot 54)
79
Evaluation Trapezoid Window X1 (Slot 55)
79
Evaluation Trapezoid Window X2 (Slot 56)
81
Evaluation Trapezoid Window Y1 (Slot 57)
81
Evaluation Trapezoid Window Y2 (Slot 58)
83
Evaluation Threshold 1 (Slot 59)
83
Evaluation Threshold 2 (Slot 60)
85
Evaluation Threshold 3 (Slot 61)
86
Evaluation Threshold 4 (Slot 62)
86
Evaluation Envelope 1 (Slot 63 to 67)
86
Evaluation Envelope 2 (Slot 68 to 72)
86
Evaluation Rotary Switch 1 (Slot 73)
86
Evaluation Rotary Switch 2 (Slot 74)
86
Evaluation Mathematical Functions (Slot 75)
86
Tolerance Band for Evaluation Elements (Slot 76)
96
Realtime Switchpoints S1 (Slot 77)
96
Realtime Switchpoints S2 (Slot 78)
97
Realtime Switchpoints S3 (Slot 79)
97
Realtime Switchpoints S4 (Slot 80)
97
Sensortest (Slot 81)
97
Setup User-Defined Values (Slot 82)
98
Copy/Initialize Measurement Programs (Slot 83)
100
Reference Curve Y1, Y2 (Slot 84 to 88)
101
Test Operation (Slot 89)
101
Zoom and Autoscale (Slot 90)
101
Measurement Results
103
Status of Measurement
103
Further Information for Current Measurement Curve
103
Further Information for Current Pretrigger Curve
104
General Curve Data Channel Y1
105
General Curve Data Channel Y2
105
Request Measurement Results of User-Defined Values
105
Statistic Measurement Result Evaluation Element Window 1 (Evelem 1)
112
Statistic Measurement Result Evaluation Element Window 2 (Evelem 2)
112
Statistic Measurement Result Evaluation Element Window 3 (Evelem 3)
112
Statistic Measurement Result Evaluation Element Window 4 (Evelem 4)
112
Statistic Measurement Result Evaluation Element Window 5 (Evelem 5)
112
Statistic Measurement Result Evaluation Element Window 6 (Evelem 6)
112
Statistic Measurement Result Evaluation Element Window 7 (Evelem 7)
112
Statistic Measurement Result Evaluation Element Window 8 (Evelem 8)
112
Statistic Measurement Result Evaluation Element Window 9 (Evelem 9)
113
Statistic Measurement Result Evaluation Element Window 10 (Evelem 10)
113
Statistic Measurement Result Evaluation Element Threshold 1 (Evelem 11)
113
Statistic Measurement Result Evaluation Element Threshold 2 (Evelem 12)
113
Statistic Measurement Result Evaluation Element Threshold 3 (Evelem 13)
113
Statistic Measurement Result Evaluation Element Threshold 4 (Evelem 14)
113
Statistic Measurement Result Evaluation Element Trapezoid Window X1 (Evelem 15)
113
Statistic Measurement Result Evaluation Element Trapezoid Window X2 (Evelem 16)
113
Statistic Measurement Result Evaluation Element Trapezoid Window Y1 (Evelem 17)
113
Statistic Measurement Result Evaluation Element Trapezoid Window Y2 (Evelem 18)
113
Statistic Measurement Result Evaluation Element Mathematical Calculation 1 (Evelem 21)
114
Statistic Measurement Result Evaluation Element Mathematical Calculation 2 (Evelem 22)
114
Statistic Measurement Result Evaluation Element Mathematical Calculation 3 (Evelem 23)
114
Statistic Measurement Result Evaluation Element Mathematical Calculation 4 (Evelem 24)
114
Statistic Measurement Result Evaluation Element Mathematical Calculation 5 (Evelem 25)
114
Statistic Measurement Result Evaluation Element Mathematical Calculation 6 (Evelem 26)
114
Read-Out Curve Coordinates of Current Measurement Curve with Single Array Access
115
9.2.34 Read-Out Y1-Coordinates of Current Measurement Curve
117
9.2.35 Read-Out Y2-Coordinates of Current Measurement Curve
117
9.2.36 Read-Out X-Coordinates of Current Pretrigger Curve
118
9.2.37 Read-Out Y1-Coordinates of Current Pretrigger Curve
119
9.2.38 Read-Out Y2-Coordinates of Current Pretrigger Curve
119
Evaluation Results Window 1
119
Evaluation Results Window 2
120
Evaluation Results Window 3
121
Evaluation Results Window 4
121
Evaluation Results Window 5
121
Evaluation Results Window 6
121
Evaluation Results Window 7
121
Evaluation Results Window 8
122
Evaluation Results Window 9
122
Evaluation Results Window 10
122
Evaluation Results Threshold 1
122
Evaluation Results Threshold 2
123
Evaluation Results Threshold 3
124
Evaluation Results Threshold 4
124
9.2.53 Evaluation Results Trapezoid Window X1
124
Evaluation Results Trapezoid Window X2
124
9.2.55 Evaluation Results Trapezoid Window Y1
125
9.2.56 Evaluation Results Trapezoid Window Y2
125
Evaluation Results Envelope 1
125
Evaluation Results Envelope 2
126
Evaluation Results Rotary Switch Evaluation Element 1
126
Evaluation Results Rotary Switch Evaluation Element 2
135
9.2.61 Evaluation Results Mathematical Functions
135
Combined Results (Common Curve Data and Evalution Elements)
136
10 Appendix
139
Operand Table for Mathematical Functions
139
Error Codes
154
Advertisement
burster DIGIFORCE 9311 Operation Manual (27 pages)
FOR MONITORING PRESS-FIT, JOINING, RIVET AND CAULKING OPERATIONS
Brand:
burster
| Category:
Test Equipment
| Size: 3.04 MB
Table of Contents
Table of Contents
2
Introduction
3
Creating New Project
4
Installation of GSD File
6
Creation of Network Connections
7
Create a Sample Program
13
Further Examples
18
Reading and Writing of String Data Types
19
Retrieving of Measurement Results
22
Changing of Window Limits
25
Burster DIGIFORCE 9311 Operation Manual (21 pages)
PROFINET Integration into TIA Portal
Brand:
Burster
| Category:
Control Unit
| Size: 2.37 MB
Table of Contents
Table of Contents
2
Introduction
3
Creating New Project
4
Installation of GSDML Files
6
Creation of Network Connections
7
Create a Sample Program
10
Further Examples
15
Reading and Writing of String Data Types
16
Retrieving of Measurement Results
18
Changing of Window Limits
20
Advertisement
Related Products
Burster DIGIFORCE 9307
Burster DIGIFORCE 9310
Burster 9163
Burster 9186-V Series
Burster 9186-V31 Series
Burster 9181
Burster 9180
Burster Digiforce 9311-V2 Series
Burster 9235
Burster 9206
Burster Categories
Measuring Instruments
Accessories
Test Equipment
Recording Equipment
Control Unit
More Burster Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL