Sign In
Upload
Manuals
Brands
AAON Manuals
Controller
Orion VCCX2
User Manuals: AAON Orion VCCX2 HVAC Controller
Manuals and User Guides for AAON Orion VCCX2 HVAC Controller. We have
4
AAON Orion VCCX2 HVAC Controller manuals available for free PDF download: Technical Manual
AAON Orion VCCX2 Technical Manual (140 pages)
Brand:
AAON
| Category:
Controller
| Size: 31 MB
Table of Contents
Table of Contents
3
Overview
9
System Features
9
Applications
10
Part Number Cross Reference
11
Parts and Descriptions
12
Controller with Enclosure Components
19
Figure 1: VCCX2 Controller with Enclosure Components
19
Figure 2: VCCX2 Controller Dimensions
20
Refrigerant System Module (RSM) (Typical)
21
Dimensions
20
VCCX-2 Controller
20
Figure 3: Typical Refrigerant System Module Dimensions (RSMV Shown)
21
Figure 4: VCC-X EM1 Expansion Module Dimensions
22
12-Relay E-BUS Module
23
VCC-X EM1 Expansion Module
22
Figure 5: 12-Relay E-BUS Module Dimensions
23
Table 1: Voltage and Environment Requirements
24
VCCX2 Controller Inputs
25
Wiring
24
Important Wiring Considerations
24
Figure 6: VCCX2 Controller Input Wiring
25
Figure 7: VCCX2 Controller Output Wiring
26
Figure 8: Figure 8: E-BUS Digital Room Sensor Wiring
27
E-BUS CO 2 Wall-Mounted Sensor
28
Figure 9: Wall Mounted E-BUS CO2 Sensor Wiring
28
Duct Mounted E-BUS CO 2 Sensor
29
Figure 10: Duct Mounted E-BUS CO2 Sensor Wiring
29
Figure 11: Space Temperature Sensor Wiring and Slide Adjust
30
Space Temperature Sensor
30
Figure 12: Supply Air Temperature Sensor Wiring
31
Supply Air Temperature Sensor
31
Figure 13: Return Air Temperature Sensor Wiring
32
Return Air Temperature Sensor
32
Building Pressure Sensor
33
Figure 14: Building Pressure Sensor Wiring Diagram
33
Figure 15: Remote SAT Reset Signal Wiring Diagram
34
Remote SAT Reset
34
E-BUS Outdoor Air Temperature Sensor
35
Figure 16: Outdoor Air Temperature Sensor Wiring
35
E-BUS Outdoor Air Temperature and Humidity Sensor
36
Figure 17: E-BUS Outdoor Air Temperature & Humidity Sensor Wiring
36
E-BUS Return Air Temperature and Humidity Sensor
37
Figure 18: E-BUS Return Air Temperature & Humidity Sensor Wiring
37
Figure 19: Static Pressure Transducer Wiring Diagram
38
Static Pressure Transducer
38
Figure 20: Supply Fan VFD Wiring
39
Supply Fan VFD or Bypass Damper Actuator
39
Economizer Actuator or WSE Actuator
40
Figure 21: Economizer Damper Actuator or WSE Valve Actuator Wiring
40
Figure 22: Modulating Heating Device Wiring
41
Modulating Heating Device
41
Building Pressure Control Outputs
42
Figure 23: Building Pressure Control Output Wiring Diagram
42
Entering H 2 0 Temp Sensor, RA Plenum, and Return/Exhaust Fan Proving
43
Figure 24: Entering Water Temperature Sensor, Return Air Plenum Pressure & Return/Exhaust Proof of Flow
43
Figure 25: Entering Water Temperature Sensor Location
44
VCC-X EM1 Entering Water Temperature Sensor
44
Figure 26: VCC-X EM1 Exhaust Duct Static Pressure & Economizer Actuator Feedback Wiring
45
VCC-X EM1 Expansion Module Inputs
45
Figure 27: VCC-X EM1 Expansion Module Output Wiring Diagram
46
VCC-X EM1 Expansion Module Outputs
46
Chilled Water Valve Actuator
47
Figure 28: Chilled Water Valve Actuator Wiring Diagram
47
Figure 29: Return Air Bypass Wiring
48
Return Air Bypass
48
12-Relay E-BUS Expansion Module
49
Figure 30: E-BUS 12-Relay Expansion Module Wiring
49
EBTRON ® , Greentrol TM , and Paragon Digital Transmitters
50
Figure 31: EBTRON ® GTC116 or HTN104 Series, Greentrol
50
Figure 32: RSMV Inputs Wiring
51
RSMV Controller Inputs
51
RSMV Controller Outputs
52
E-BUS Digital Room Sensor
27
VCCX2 Controller Outputs
26
Figure 33: RSMV Outputs Wiring
52
Wiring
53
Figure 34: RSMV-HP Inputs Wiring
53
Figure 35: RSMV-HP Outputs Wiring
54
Figure 36: RSMD Inputs Wiring
55
Figure 37: RSMD Outputs Wiring
56
RSMD Controller Outputs
56
Figure 38: RSMZ Inputs Wiring
57
RSMZ Controller Inputs
57
Figure 39: RSMZ Outputs Wiring
58
RSMZ Controller Outputs
58
Figure 40: Subcool Monitor Controller Wiring
59
Subcool Monitor Controller
59
Figure 41: MHGRV-X Controller to VCCX2 Controller Wiring
60
MHGRV-X Controller
60
Figure 42: MODGAS-X Controller to VCCX2 Controller Wiring Diagram
61
MODGAS-X Controller
61
Figure 43: MODGAS-XWR2 Controller to VCCX2 Controller Wiring Diagram
62
MODGAS-XWR2 Controller
62
PREHEAT-X and PREHEAT-X-EXT Controller
63
RSMD Controller Inputs
55
RSMV-HP Controller Inputs
53
RSMV-HP Controller Outputs
54
Figure 44: PREHEAT-X Controller to VCCX2 Controller Wiring
63
Figure 45: Modular Service Tool SD, Modular System Manager SD, System Manager TS-L, and Prism 2 Software
64
Start - up and Commissioning
64
Powering up and Configuration
64
Table 3: VCC-X EM1 Inputs & Outputs
65
Table 2: VCCX2 Controller Inputs & Outputs (Continued)
65
Table 2: VCCX2 Controller Inputs & Outputs
65
VCCX2 Controller Inputs
66
VCCX2 Controller Outputs
67
VCC-X EM1 Expansion Module
68
E-BUS 12-Relay Expansion Module
69
Inputs and Outputs
65
VCCX2 Controller and EM1 Module Input/Output Maps
65
Table 4: User-Configurable Relay Outputs
69
Sequence of Operations
70
Supply Fan and Occupied/Unoccupied Operation
70
HVAC Modes of Operation
71
Economizer Operation
73
Dehumidification Mode
74
Reheat, Coil Suction, and Return Air Bypass Damper
75
Heating Mode
76
Ventilation Mode, Remote Contact Control, and Space Sensor Operation
77
IAQ Control, Morning Warm-Up and Cool-Down, and Single Zone VAV
79
Airflow Monitoring, Pre-Heater, Low Ambient and Duct Static Press
81
Duct Static Setpoint Reset and Duct Static Pressure Control
82
Building Pressure Control and Exhaust Duct Static Pressure Control
83
MUA, CAV/MUA, and Space Temperature Control
84
VAV W/Sa Tempering, Air to Air Heat Pump and Standard Defrost
85
Heat Pump Adaptive Defrost, WSHP, EXV and Head Pressure
86
Evaporative Condenser, WSE, OA Lockouts and Temp Protection
87
Alarm Detection and Sensor Failure Alarms
89
Mechanical Failure and Failure Mode Alarms
91
Title 24 Economizer Alarms
92
Table 5: VCCX2 Controller Trend Logs
93
Table 6: RSMV/RSMD Module Trend Logs
93
VCCX2 Controller Trend Logs
93
RSMV/RSMD/RSMZ Trend Logs and Trend Log Enumerated Values
94
Table 8: Trend Log Enumerated Values
94
Table 7: RSMZ Module Trend Logs
94
Table 6: RSMV / RSMD Module Trend Logs (Continued)
94
RSMZ Trend Logs and Trend Log Enumerated Values
95
Table 10: RSMZ Module RSM Alarm Trend Log
95
Table 9: RSMZ Module Comp Status Trend Log
95
Table 11: RSMZ Module VFD Status Trend Log
96
Table 13: RSMZ Module VFD Alarm 2 Trend Log
96
Table 12: RSMZ Module VFD Alarm 1 Trend Log
96
Trend Log Bit String Decoding
97
Table 14: VCCX2 Trend Log Bit Strings
98
Table 14: VCCX2 Trend Log Bit Strings (Continued)
99
Troubleshooting
100
VCCX2 Controller and EM1 LED Diagnostics
100
Figure 47: VCC-X EM1 Expansion Module LED Locations
101
Table 15: 0-5V Temperature Sensor - Voltage & Resistance for Type III Sensors
102
Duct Static Pressure and Building Pressure Sensor Testing
103
Figure 46: VCCX2 Controller LED Locations
101
Temperature Sensor Testing
102
Table 16: Duct Static Pressure/Voltage for Duct Static Pressure Sensors
103
Table 17: Building Static Pressure/Voltage for Building Pressure Sensors
103
Appendix A - System Configuration
104
Figure 48: Available Operator Interfaces
104
Figure 49: Typical Stand-Alone System Layout
105
Figure 50: Typical Interconnected System Layout
106
Networked System Single Loop Layout
107
Interconnected System Layout
106
System Configurations
104
Stand-Alone System Layout
105
Figure 51: Typical Networked Single Loop System Layout
107
Appendix B - Vccx2 Lcd Screens
108
Figure 52: LCD Display and Navigation Keys
108
Navigation Keys
108
Table 18: Navigation Key Functions
108
Table 19: Editing Key Functions
108
Main Screens Map
109
Setting Screens
110
Status Screens
111
Alarm Screens
112
Output Override Screens
113
Air Balance Screens and Factory Test Mode Screen
114
Figure 53: VCCX2 Bacnet ® Connection to MS/TP Network
115
Appendix C - Vccx2 Bacnet
115
VCCX2 Bacnet ® Parameters
115
Index
137
Advertisement
AAON Orion VCCX2 Technical Manual (134 pages)
Latest Main controller updatable and customizable
Brand:
AAON
| Category:
Controller
| Size: 21 MB
Table of Contents
Table of Contents
3
Overview
9
Features
9
Applications
10
Part Number Cross Reference
11
Parts and Descriptions
12
VCCX2 Controller Components
19
Figure 1: VCCX2 Controller Components
19
Dimensions
20
VCCX2 Controller
20
Figure 2: VCCX2 Controller Dimensions
20
Refrigerant System Module
21
Figure 3: Typical Refrigerant System Module Dimensions (RSMV Shown)
21
VCC-X EM1 Expansion Module
22
Figure 4: VCC-X EM1 Expansion Module Dimensions
22
12 Relay E-BUS Module
23
Figure 5: 12 Relay E-BUS Module Dimensions
23
Wiring
24
Important Wiring Considerations
24
Table 1: Voltage and Environment Requirements
24
VCCX2 Controller Inputs
25
Figure 6: VCCX2 Controller Input Wiring
25
VCCX2 Controller Outputs
26
Figure 7: VCCX2 Controller Output Wiring
26
E-BUS Digital Room Sensor
27
Figure 8: E-BUS Digital Room Sensor Wiring
27
Wall-Mounted E-BUS CO
28
Figure 9: Wall-Mounted E-BUS CO
28
Duct-Mounted E-BUS CO
29
Figure 10: Duct-Mounted E-BUS CO Sensor Wiring
29
Space Temperature Sensor
30
Figure 11: Space Temperature Sensor Wiring and Slide Adjust
30
Supply Air Temperature Sensor
31
Figure 12: Supply Air Temperature Sensor Wiring
31
Return Air Temperature Sensor
32
Figure 13: Return Air Temperature Sensor Wiring
32
Building Pressure Sensor
33
Figure 14: Building Pressure Sensor Wiring
33
Remote Supply Air Temperature Reset
34
Figure 15: Remote SAT Reset Signal Wiring
34
E-BUS Outdoor Air Temperature Sensor
35
Figure 16: Outdoor Air Temperature Sensor Wiring
35
E-BUS Outdoor Air Temperature and Humidity Sensor
36
Figure 17: E-BUS Outdoor Air Temperature and Humidity Sensor Wiring
36
E-BUS Return Air Temperature and Humidity Sensor
37
Figure 18: E-BUS Return Air Temperature and Humidity Sensor Wiring
37
Duct Static Pressure Transducer
38
Figure 19: Static Pressure Transducer Wiring
38
Supply Fan VFD or Bypass Damper Actuator
39
Figure 20: Supply Fan VFD Wiring
39
Economizer Damper Actuator or Waterside Economizer Actuator
40
Figure 21: Economizer Damper Actuator or Waterside Economizer Actuator Wiring
40
Modulating Heating Device
41
Figure 22: Modulating Heating Device Wiring
41
Building Pressure Control Outputs
42
Figure 23: Building Pressure Control Output Wiring
42
VCC-X EM1 Expansion Module
43
Figure 24: Entering Water Temperature Sensor, Return Air Plenum Pressure and Return/Exhaust Proof of Flow
43
Entering Water Temperature Sensor
44
Figure 25: Entering Water Temperature Sensor
44
VCC-X EM1 Expansion Module Inputs
45
Figure 26: VCC-X EM1 Exhaust Duct Static Pressure and Economizer Actuator Feedback Wiring
45
VCC-X EM1 Expansion Module Outputs
46
Figure 27: VCC-X EM1 Expansion Module Output Wiring
46
Modulating Cooling Output
47
Figure 28: Chilled Water Valve Actuator Wiring
47
Return Air Bypass
48
Figure 29: Return Air Bypass Wiring
48
12 Relay E-BUS Expansion Module
49
Figure 30: 12 Relay E-BUS Expansion Module Wiring
49
EBTRON, Greentrol, and Paragon Digital Transmitters
50
Figure 31: EBTRON GTC116 or HTN104 Series, Greentrol GA-200-N Series, and Paragon Microtrans
50
RSMV Inputs
51
Figure 32: RSMV Inputs Wiring
51
RSMV Outputs
52
Figure 33: RSMV Outputs Wiring
52
RSMV-HP Inputs
53
Figure 34: RSMV-HP Inputs Wiring
53
RSMV-HP Outputs
54
Figure 35: RSMV-HP Outputs Wiring
54
RSMD Inputs
55
Figure 36: RSMD Inputs Wiring
55
RSMD Outputs
56
Figure 37: RSMD Outputs Wiring
56
RSMZ Inputs
57
Figure 38: RSMZ Inputs Wiring
57
RSMZ Outputs
58
Figure 39: RSMZ Outputs Wiring
58
Subcool Monitor Module
59
Figure 40: Subcool Monitor Wiring
59
Mhgrv-X
60
Figure 41: MHGRV-X to VCCX2 Controller Wiring
60
Modgas-X
61
Figure 42: MODGAS-X to VCCX2 Controller Wiring
61
Modgas-Xwr2
62
Figure 43: MODGAS-XWR2 to VCCX2 Controller Wiring
62
PREHEAT-X and PREHEAT-X-EXT
63
Figure 44: PREHEAT-X to VCCX2 Module Wiring
63
Start-Up and Commissioning
64
Powering up and Configuration
64
Figure 45: Operator Interfaces
64
Inputs and Outputs
65
VCCX2 Controller and EM1 Module Input/Output Maps
65
Table 2: VCCX2 Controller Inputs and Outputs
65
Table 3: VCC-X EM1 Inputs and Outputs
65
VCCX2 Controller Inputs
66
VCCX2 Controller Outputs
67
VCC-X EM1 Expansion Module
68
12 Relay E-BUS Expansion Module
69
Table 4: User-Configurable Relay Outputs
69
Sequence of Operations
70
Supply Fan Operation and HVAC Source Configuration Options
70
Occupied/Unoccupied Operation and HVAC Modes of Operation
71
Cooling Mode
72
Economizer Operation
73
Dehumidification Mode
74
Reheat, Coil Suction, and Return Air Bypass Damper Control
75
Heating Mode
76
Ventilation Mode, Remote Contact Control, and Space Sensor Operation
77
Indoor Air Quality and Morning Mode Operations
78
Single Zone Variable Air Volume
79
Supply Air Temperature, Airflow Monitoring, and Preheater Operation
80
Low Ambient Operation, Heat Wheel, and Duct Static Pressure Control
81
Duct Static Setpoint Reset, Building Pressure Control
82
Exhaust Duct Static Pressure Control
83
Make-Up Air, Dual Mode, and Space Temperature Control
84
Variable Air Volume with Supply Air Tempering and Air to Air Heat Pump
85
Heat Pump Standard Defrost, Adaptive Defrost, and Water Source Heat Pump
86
Electronic Expansion Valve Operation, Head Pressure, and Evaporative Condenser
87
Waterside Economizer, Temperature Protection, and Outdoor Air Lockouts
88
System Broadcasts and Alarm Detection
89
Sensor Failure Alarms
90
Mechanical Failure and Failure Mode Alarms
91
Title 24 Economizer Alarms
92
VCCX2 Controller Trend Logs
93
Table 5: VCCX2 Controller Trend Logs
93
RSMV/RSMD/RSMZ Trend Logs
94
Table 6: RSMZ Module Trend Logs
94
Table 7: RSMV/RSMD Module Trend Logs
94
RSMZ Trend Logs and Trend Log Enumerated Values
95
Table 8: Trend Log Enumerated Values
95
Table 9: RSMZ Module Comp Status Trend Log
95
Table 10: RSMZ Module RSM Alarm Trend Log
95
RSMZ Trend Logs
96
Table 11: RSMZ Module VFD Status Trend Log
96
Table 12: RSMZ Module VFD Alarm 1 Trend Log
96
Table 13: RSMZ Module VFD Alarm 2 Trend Log
96
Trend Log Bit String Decoding
97
Trend Log Bit String Decoding
98
Table 14: VCCX2 Trend Log Bit Strings
98
Troubleshooting
99
VCCX2 Controller and EM1 LED Diagnostics
99
Figure 46: VCCX2 Controller LED Locations
100
Figure 47: VCC-X EM1 Expansion Module LED Locations
100
Temperature Sensor Testing
101
Table 15: 0-5V Temperature Sensor - Voltage and Resistance for Type III Sensors
101
Duct Static Pressure and Building Pressure Sensor Testing
102
Table 16: Duct Static Pressure/Voltage for Duct Static Pressure Sensors
102
Table 17: Building Static Pressure/Voltage for Building Pressure Sensors
102
Appendix A - System Configuration
103
System Configurations
103
Stand-Alone System Layout
104
Figure 48: Typical Stand-Alone System Layout
104
Networked System Single Loop Layout
105
Figure 49: Typical Networked Single Loop System Layout
105
Networked System Multiple Loop Layout
106
Figure 50: Typical Networked Multiple Loop System Layout
106
Appendix B - Vccx2 Lcd Screens
107
Navigation Keys
107
Figure 51: LCD Display and Navigation Keys
107
Table 18: Navigation Key Functions
107
Table 19: Editing Key Functions
107
Main Screens Map
108
Setting Screens
109
Status Screens
110
Alarm Screens
111
Table 20: Alarm Screens
111
Output Override Screens
112
Air Balance Screens
113
Appendix C - Vccx2 Bacnet
114
VCCX2 Bacnet Connection to MS/TP Network
114
Figure 52: VCCX2 Bacnet Connection to MS/TP Network
114
VCCX2 Bacnet Parameters - Analog Inputs
115
VCCX2 Bacnet Parameters - Analog Values
122
VCCX2 Bacnet Parameters - Binary Inputs
127
VCCX2 Bacnet Bitfields
130
VCCX2 Bacnet PICS
133
AAON Orion VCCX2 Technical Manual (116 pages)
Brand:
AAON
| Category:
Controller
| Size: 11 MB
Table of Contents
Table of Contents
3
Vccx2
5
Overview
6
Features
6
Single Zone VAV
6
Static Pressure Control
6
Steam Valve
6
Trend Logging
6
Applications
7
Part Number Cross Reference
8
Overview
8
Strap-On Temperature Sensor Kit
8
USB-Link 2 Kit
8
Parts List
9
Slide Adjust
10
Standard Room Sensor
10
Applications
11
VCCX2 Controller Dimensions
16
Typical RSM Module Dimensions
17
EM1 Expansion Module Dimensions
18
Sig1
18
Static Pressure
18
Relay Expansion Module Dimensions
19
VCCX2 Controller Components
20
Installation & Wiring
21
Powering-Up
21
VA Rating
21
VCCX2 Input and Output Wiring
22
E-BUS Digital Room Sensor
24
E-BUS Digital Room Sensor Wiring
24
E-BUS CO Wall Mounted Sensor
25
Duct Mounted E-BUS CO Sensor
26
Space Temperature Sensor & Slide Adjust
27
Space Temperature Sensor
27
Supply Air Temperature Sensor
28
Supply Air Temperature Sensor Wiring
28
Return Air Temperature Sensor
29
Building Static Pressure Sensor
30
Remote SAT Reset Signal
31
Outdoor Air Temperature Sensor
32
E-BUS Outdoor Air Temperature and Humidity Sensor
33
E-BUS Return Air Temperature and Humidity Sensor
34
Suction Pressure Transducer Kit
35
Static Pressure Transducer Wiring
35
Supply Fan VFD Signal or Bypass Damper Actuator
36
Economizer Damper Actuator
37
Waterside Economizer Actuator
37
Modulating Heating Device
38
Building Pressure Control Output
39
VCC-X EM1 Expansion Module Input Wiring
40
Entering Water Temperature Sensor
40
Exhaust Duct Static Pressure Sensor
42
Economizer Actuator Feedback
42
For VCCX2 Controller
42
VCC-X EM1 Expansion Module Output Wiring
43
Chilled Water
44
Return Air Bypass
45
E-BUS 12 Relay Expansion Module Wiring
46
EBTRON ® , Greentrol™, and Paragon Air Flow Measurement Digital Transmitter
47
RSMV Input Wiring
48
RSMV Output Wiring
49
Suction Pressure Sensor Wiring
49
RSMV-HP Input Wiring
50
RSMV-HP Output Wiring
51
RSMD Input Wiring
52
RSMD Output Wiring
53
RSMSD Input Wiring
54
RSMSD Output Wiring
55
MHGRV-X Controller
56
Supply Air Temperature
56
Supply Air Temperature Sensor
56
MODGAS-X Controller
57
PREHEAT-X Controller
58
Start-Up & Commissioning
59
Confi Guring the Controller
59
Inputs & Outputs
60
VCCX2 Controller Inputs & Outputs
60
VCCX2 Controller Inputs & Outputs
61
Unoccupied Mode of Operation
61
VCC-X EM1 Inputs & Outputs
63
Relay Outputs
63
User-Confi Gurable Relay Outputs
63
Sequence of Operations
64
Supply Fan Operation Mode
64
HVAC Source Confi Guration Options
64
Occupied / Unoccupied Mode
64
Space Temperature
64
Supply Fan Operation
64
Cooling Mode
65
Economizer Operation (Standard)
66
Comparative Enthalpy Economizer Operation
66
Dehumidifi Cation Mode
66
Heating Mode
68
Ventilation Mode
69
Off Mode
69
VCCX2 Remote Contact Control
69
Space Sensor Operation
69
IAQ (CO ) Control Operation
69
Morning Warm-Up Mode Operation
69
Morning Cool-Down Mode Operation
70
Single Zone VAV
70
Supply Air Temperature Setpoint Reset
70
VAV Cooling
70
Airfl Ow Monitoring
71
Pre-Heater Operation
71
Low Ambient Operation
71
Heat Wheel Operation
71
Supply Air Temperature Setpoint Reset
71
Duct Static Pressure Control
72
Duct Static Setpoint Reset
72
Duct Static Pressure Control for Filter Loading
72
Building Pressure Control
72
Economizer Control Signal
72
Exhaust Duct Static Pressure Control of Exhaust Fan
73
MUA Operation
73
CAV/MUA Dual Mode (Hood On/Off Operation)
73
Space Temperature Control of High Percentage Outside Air Units
73
Head Pressure Control
73
VAV Operation with Outdoor Air Temperature Control
74
Air to Air Heat Pump Operation
74
Heat Pump Standard Defrost Operation
74
Heat Pump Adaptive Defrost Operation
75
Water Source Heat Pump Operation
75
Electronic Expansion Valve (EXV) Operation
75
Waterside Economizer Operation
76
Waterside Economizer Flush Cycle
76
Temperature Protection
76
Outdoor Air Lockouts
76
System Broadcasts
76
Alarm Detection and Reporting
77
Sensor Failure Alarms
77
Supply Air Temperature Sensor Failure Alarm
77
Mechanical Failure Alarms
78
Failure Mode Alarms
78
Title 24 Economizer Alarms
78
Trend Logging
79
Troubleshooting
80
LED Diagnostics
80
VCCX2 Controller & VCC-X EM1 Expansion Module LED Locations
81
Space, Outdoor Air, or Return Air Temperature Sensor Testing
82
Temperature/Resistance for Type III 10K Ohm Thermistor Sensors
82
Temperature Sensor Testing
82
Thermistor Sensor Testing Instructions
82
OE271 & OE258-01 Pressure Sensor Testing
83
OE258-01 Pressure Sensor
83
OE271 Pressure Sensor
83
Appendix A - System Configurations
84
Stand-Alone System
84
System Manager TS
84
Service Tool
85
APPENDIX B - VCCX2 LCD Display Screens
88
Main Screens Map
89
Supply Fan VFD
93
APPENDIX C - VCCX2 Bacnet ® Connection to MS/TP Network, Bacnet Parameters & PICS Statement
95
Connection to MS/TP Network
95
Confi Guration
102
Confi Guring
103
Alarms
107
VCCX2 Bacnet
108
VCCX2 Controller
109
Index
110
Advertisement
AAON Orion VCCX2 Technical Manual (95 pages)
Brand:
AAON
| Category:
Controller
| Size: 10 MB
Table of Contents
Table of Contents
3
Table of Figures
5
Table of Tables
6
Overview
7
Features
7
Applications
8
Part Number Cross Reference
9
VCCX2 Controller Components
11
Figure 1: VCCX2 Controller Components
11
Dimensions
12
VCCX2 Controller
12
Figure 2: VCCX2 Controller Dimensions
12
VCC-X EM1 Expansion Module
13
Figure 3: VCC-X EM1 Expansion Module Dimensions
13
12 Relay E-BUS Module
14
Relay E-BUS Module Dimensions
14
Wiring
15
Important Wiring Considerations
15
Table 1: Voltage and Environment Requirements
15
VCCX2 Controller
16
Figure 5: VCCX2 Controller Input Wiring
16
Figure 6: VCCX2 Controller Output Wiring
17
VCC-X EM1 Expansion Module
18
Figure 7: Entering Water Temperature Sensor, Return Air Plenum Pressure and Return/Exhaust Proof of Flow
18
Figure 8: Direct Fire Wiring
18
Figure 9: VCC-X EM1 Exhaust Duct Static Pressure and Economizer Actuator Feedback Wiring
19
Figure 10: VCC-X EM1 Expansion Module Output Wiring
20
12 Relay E-BUS Expansion Module
21
Airflow Station
22
Figure 12: EBTRON GTC116 or HTN104 Series, Greentrol GA-200-N Series, and Paragon Microtranseq Series Airflow Measurement Digital Transmitter Wiring
22
Start-Up and Commissioning
23
Powering up and Configuration
23
Figure 13: Operator Interfaces
23
Inputs and Outputs
24
VCCX2 Controller and EM1 Module Inputs/Outputs Maps
24
Table 2: VCCX2 Controller Analog Inputs
24
Table 3: VCCX2 Controller Binary Inputs
24
Table 4: VCCX2 Controller Analog Outputs
24
Table 5: VCCX2 Controller Relay Outputs
24
Table 6: VCC-X EM1 Expansion Module Analog Inputs
25
Table 7: VCC-X EM1 Expansion Module Binary Inputs
25
Table 8: VCC-X EM1 Expansion Module Analog Outputs
25
Table 9: VCC-X EM1 Expansion Module Relay Outputs
25
VCCX2 Controller Inputs/Outputs Descriptions
26
VCC-X EM1 Expansion Module Inputs/Outputs Descriptions
28
User Configurable Relay Outputs
29
Sequence of Operations
30
Configuration Options
30
Modes of Operation
32
Alarms
47
Figure 14: Prism 2 ALARM Button
47
Figure 15: Prism 2 ALARM Menu
47
Figure 16: Prism 2 Direct Fire Alarms Screen
49
Figure 17: Prism 2 Compressor Alarms Screen
50
Figure 18: Prism 2 EVAP Module Alarms Screen
50
Trend Logs
51
Table 11: VCCX2 Controller Trend Logs
51
Table 12: RSMZ Module Trend Log
51
Table 13: RSMV/RSMD Module Trend Logs
52
Table 14: RSMZ Trend Log Enumerated Values
52
Table 15: RSMZ Module Comp Status Trend Log
53
Table 16: RSMZ Module RSM Alarm Trend Log
53
Table 17: RSMZ Module VFD Status Trend Log
53
Table 18: VCCX2 Trend Log Bit Strings
55
Table 19: VCCX2 Trend Log Bit Strings (Continued)
56
Troubleshooting
57
LED Diagnostics
57
Figure 19: VCCX2 Controller LED Locations
58
Figure 20: VCC-X EM1 Expansion Module LED Locations
58
Temperature Sensor Testing
59
Table 20: 0-5V Temperature Sensor - Voltage and Resistance for Type III Sensors
59
Pressure Sensor Testing
60
Table 21: Duct Static Pressure/Voltage for Duct Static Pressure Sensors
60
Table 22: Building Static Pressure/Voltage for Building Pressure Sensors
60
Appendix A: System Configuration
61
Options
61
Stand-Alone System Layout
62
Figure 21: Typical Stand-Alone System Layout
62
Networked System Single Loop Layout
63
Figure 22: Typical Networked Single Loop System Layout
63
Networked System Multiple Loop Layouts
64
Figure 23: Typical Networked Multiple Loop System Layout
64
Appendix B: Lcd Screens
65
LCD Display Screen and Navigation Keys
65
Figure 24: LCD Display and Navigation Keys
65
Table 23: Navigation Key Functions
65
Table 24: Editing Key Functions
65
Main Screens Map
66
Screen Descriptions
67
Table 25: Main Screens
67
Table 26: Controller Screens
67
Table 27: Settings Screens
68
Table 28: Status Screens
68
Table 29: Alarms Screens
69
Table 30: Output Override Screens
70
Table 31: Air Balance Screens
70
Appendix C: Bacnet Guide
71
Bacnet Connection to MS/TP Network
71
Figure 25: VCCX2 Bacnet Connection to MS/TP Network
71
Analog Inputs
72
Analog Values
80
Binary Inputs
86
Enumerated Fields
90
Table 32: VCCX Control Mode = Enumerated
90
Table 33: VCCX Control Status = Enumerated
90
Table 34: VCCX Mode Status = Enumerated
90
Bitfields
91
Table 35: RSMZ Warnings Status Bit Strings
91
Table 36: RSMZ Faults Status Bit Strings
91
Table 37: RSMZ Lockout Status Bit Strings
91
Table 38: RSMZ Drive Status Bit Strings
91
Table 39: RSMZ Module VFD1 Alarm Trend Log
92
Table 40: RSMZ Module VFD2 Alarm Trend Log
92
Bacnet Protocol Implementation Conformance Statement - VCCX2 V1.90 and Previous
93
Bacnet Protocol Implementation Conformance Statement - VCCX2 V2.00 and on
94
Advertisement
Related Products
AAON V07150
AAON V12100 MHGRV-X
AAON V82790
AAON VCCX-IP
AAON VCCX-454
AAON Orion Control Systems MiniLink PD 5
AAON Orion Control Systems ASM01626
AAON Orion BACnet General Controller
AAON V3-E
AAON V3-D
AAON Categories
Controller
Control Unit
Air Handlers
Heat Pump
Air Conditioner
More AAON Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL