Flash Test
A flash voltage of 1500VAC between LINE/NEUTRAL and
EARTH should exhibit a leakage of under 1mA. Note: where
the power cord exceeds 3M, the unit may exhibit higher
leakage. The appropriate allowance should be made.
Both insulation and flash testing may ONLY be carried out
LN-E. Testing between L-N may give erroneous results due to
the Neon indicator (if fitted).
Notes on units with integral filters
Units with integral filter systems may be LN-E insulation tested
at 500VDC but if flash tested at 1500VAC, they will exhibit high
leakage readings under insulation tests due to the nature of the
filtering components.
The quiescent earth leakage of the filter unit under normal
conditions may be checked and should not exceed 0.9mA at
250V~ 50Hz.
L to N flash and insulation tests would be inconclusive due to
the presence of the filter system and may damage the surge
suppression circuitry.
Uses
This system has been designed to conform to the latest safety
requirements. In addition to compliance with standards for
general use, this PDU has been factory configured for use in
19" rack mounting environments. This does NOT preclude their
use in other situations.

Safety Precautions

WARNING! Read and understand all sections in this guide
before installing or operating this product.
WARNING! Connect this product to an AC power source
whose voltage is within the range specified on the product's
nameplate. Operating this product outside the nameplate
voltage range may result in electric shock, fire, personal injury
and death.
WARNING! Connect this product to an AC power source that is
current limited by a suitably rated fuse or circuit breaker in
accordance with national and local electrical codes. Operating
this product without proper current limiting may result in electric
shock, fire, personal injury and death.
WARNING! Connect this product to a protective earth ground.
Never use a "ground lift adaptor" between the product's plug
and the wall receptacle. Failure to connect to a protective earth
ground may result in electric shock, fire, personal injury and
death.
WARNING! This product contains no user serviceable parts.
Do not open, alter or disassemble this product. All servicing
must be performed by qualified personnel. Disconnect power
Dominion PX Quick Setup Guide
QSG-DPX-0M-v1.5.1-E  255-80-6081-00 RoHS
before servicing this product. Failure to comply with this
warning may result in electric shock, personal injury and death.
WARNING! Use this product in a dry location. Failure to use
this product in a dry location may result in electric shock,
personal injury and death.
WARNING! Do not rely on this product's receptacle lamps,
receptacle relay switches or any other receptacle power on/off
indicator to determine whether power is being supplied to a
receptacle. Unplug a device connected to this product before
performing repair, maintenance or service on the device.
Failure to unplug a device before servicing it may result in
electric shock, fire, personal injury and death.
WARNING! Only use this product to power information
technology equipment that has a UL/IEC 60950-1 or equivalent
rating. Attempting to power non-rated devices may result in
electric shock, fire, personal injury and death.
WARNING! Do not use a Raritan product containing outlet
relays to power large inductive loads such as motors or
compressors. Attempting to power a large inductive load may
result in damage to the relay.
WARNING! Do not use this product to power critical patient
care equipment, fire or smoke alarm systems. Use of this
product to power such equipment may result in personal injury
and death.
WARNING! If this product is a model that requires assembly of
its line cord or plug, all such assembly must be performed by a
licensed electrician and the line cord or plugs used must be
suitably rated based on the product's nameplate ratings and
national and local electrical codes. Assembly by unlicensed
electricians or failure to use suitably rated line cords or plugs
may result in electric shock, fire, personal injury or death.
WARNING! This product contains a chemical known to the
State of California to cause cancer, birth defects, or other
reproductive harm.

Additional Information

For more information about the Dominion PX
Raritan product line, see Raritan's website (www.raritan.com).
For technical issues, contact Raritan Technical Support. See
the Contact Support page in the Support section on Raritan's
website for technical support contact information worldwide.
Raritan's products use code licensed under the GPL and LGPL. You can request
a copy of the open source code. For details, see the Open Source Software
Statement at
(http://www.raritan.com/about/legal-statements/open-source-software-statement
/) on Raritan's website.
and the entire
7

Advertisement

loading