General installation
instructions
IMPORTANT NOTES
• The installation must be carried out by
trained and qualified service personnel
according to the instructions contained
in this manual.
• Contact your service center before
beginning installation to avoid possible
malfunctions.
• When picking up and moving the unit,
be guided by trained and qualified
personnel.
• The ground connection of the air-
conditioner must be made correctly and
securely to the recommended earth
ground points. Contact the service
center if you have any question.
16
• Installation in the following places may
cause malfunction:
- Any place where machine oil is used.
- Any site with a lot of salinity.
- Any site with sulfured gas such as
hot springs.
- Any site subject to high-frequency
waves such as places close to radio
equipment, welders and medical
equipment.
- Any place under strong
electromagnetic fields or in a
chemical environment.
• If the air-conditioner has to be installed
on such a site, contact your service
center for advice.
> 15 cm
> 15 cm
> 200 cm
> 30 cm
> 200 cm
The above diagram represents models with one indoor unit and two
connection pipes. Some models have more than one indoor unit and
two connection pipes. These models are listed below.
- two indoor units and four connection pipes for models GE AIR 218,
GE AIR 224 and PRO AIR 218
- three indoor units and six connection pipes for model GE AIR 326
- four indoor units and eight connection pipes for model GE AIR 428
> 15 cm
> 50 cm
> 30 cm
> 50 cm
17