How To Operate Your Air-Conditioner - GE Consumer & Industrial GE AIR 107 Owner's Manual And Installation Instructions

Wall mounted split air-conditioner
Table of Contents

Advertisement

How to operate your
air-conditioner
• COOL mode operation
The microcomputer automatically
controls the rate of cooling. It adjusts the
operation of the unit according to the
actual room temperature and the desired
temperature. If the room temperature is
higher than the desired temperature, the
unit will cool the air of the room. If the fan
speed is set at AUTO mode, the
microcomputer will control the speed of
the indoor fan according to the target
temperature.
• HEAT mode operation (not available on
models GE AIR 326 and GE AIR 428)
The microcomputer automatically
controls the rate of heating. It adjusts the
operation of the unit according to the
actual room temperature and the desired
temperature. If the room temperature is
lower than the desired temperature, the
unit will heat the air of the room. If the fan
speed is set at AUTO mode, the
microcomputer will control the speed of
the indoor fan according to the target
temperature.
• DRY mode operation
Use the DRY mode to both cool the air
and reduce the moisture contained in the
air. The microcomputer automatically
adjusts the operation of the unit
according to the actual dryness and
temperature of the room, and according
to the desired temperature. If the room
temperature is higher than the target
temperature, the unit will both cool and
dry the air of the room. If the fan speed is
set at AUTO mode, the microcomputer
will control the speed of the indoor fan
according to the target temperature.
8
• AUTO mode operation
In AUTO mode, the microcomputer
automatically controls the rate of cooling
and heating of the room (only cooling for
models GE AIR 326 and GE AIR 428). If the
room temperature is higher than 25ºC,
the unit will automatically switch to COOL
mode. On models PRO AIR I109 and PRO
AIR I112, if the room temperature is lower
than 20ºC, the unit will automatically
switch to HEAT mode. On all other
models, the unit switches to HEAT mode
below 18ºC. If the fan speed is set at
AUTO mode, the microcomputer will
control the speed of the indoor fan
according to the target temperature.
• FAN mode operation
Use the FAN mode to ventilate air in the
room without cooling, heating or drying
the air. Use the FAN button of the remote
controller to set the fan speed.
• TIMER ON operation
The TIMER ON mode can only be set while
the unit is not in operation. When the unit
is stopped, press TIMER ON button to turn
it on automatically at a specified time up
to 24 hours ahead. To cancel the TIMER
ON setting, press again TIMER ON button.
• TIMER OFF operation
The TIMER OFF mode can only be set
while the unit is in operation. When the
unit is in operation, press TIMER OFF
button to turn it off automatically at a
specified time up to 24 hours ahead. To
cancel the TIMER OFF function, press
again TIMER OFF button.
• SLEEP mode operation
When the unit is cooling or drying and
operating in SLEEP mode, the target
temperature will gradually increase by
1°C per hour for two hours.
When the unit is heating and operating in
SLEEP mode, the target temperature will
gradually decrease by 1°C per hour for
two hours.
• Auto-restart function
If the network loses power, and if the unit
was in operation when the power cut
occurred, it will automatically restart
when the network regains power.
On all models except GE AIR 116 and GE
AIR 121: if your air-conditioner was not in
operation before a power cut and
automatically switches on when the
network regains power, check the
following.
- Remove surface panel of indoor unit.
- Check the switch located on the right
of the unit is set on RUN.
- If it not set on RUN, use a screw driver
to set it to RUN.
AUTO
TEST
R U N
STOP
9