Routine check after installation
What to check
For models with an indoor 4
positions switch – is the switch set
on RUN?
For models with heating capacity –
can the wastewater be drained
from the base plate of the outdoor
unit?
Has the unit been fixed firmly in
place?
Has the refrigerant leakage test
been done?
Is heat insulation sufficient?
Does the unit drain well?
Is the voltage in accordance with
the rated voltage marked on the
nameplate?
Is the electrical wiring and piping
connection installed correctly and
securely?
Has the ground connection been
made securely to recommended
earth ground points?
Is the power cord as specified?
Are the air inlet and outlet blocked?
Has the length of the connection
pipe and the thermal capacity been
verified?
26
Possible consequence
Notes
Unit will automatically start
after a power cut
Limited defrosting on the
outdoor unit and reduced
heating capacity
The unit may drop, shake or
emit noise
Reduced capacity
Condensation and dripping
Condensation and dripping
Electrical malfunction or
damaged components
Electrical malfunction or
damaged components
Electrical leakage, shock
Electrical malfunction or
damaged components
Reduced capacity
Reduced capacity
Technical specifications
Working temperature range in ˚C
(dry bulb / wet bulb temperatures)
Indoor
Outdoor
unit
unit
Maximum cooling
32 / 23
43 / 26
Minimum cooling
21 / 15
21 / -
Maximum heating
1
27 / -
24 / 18
Minimum heating
1
20 / -
-5 / -6
(1) not applicable to models GE AIR 326 and GE AIR 428