Water Filter System Specification and Performance
Data Sheet
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration of less
than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.* (100%
safety factors built-in for unmetered usage for health claims only.)
Contaminant
Average
Reduction
Influent
Chlorine Taste and
2.0 mg/L
Odor
Nominal Particulate
13,666,667
Class I, >0.5 to <
pts/mL
1.0 µm
Asbestos
96 MF/L
Atrazine
0.010 mg/L 0.009 mg/L + 10%
Cyst*
122,500
cysts/L
Lead @ pH 6.5
0.153 mg/L 0.15 mg/L + 10%
Lead @ pH 8.5
0.150 mg/L 0.15 mg/L + 10%
Lindane
0.002 mg/L 0.002 mg/L + 10%
Mercury @ pH 6.5
0.006 mg/L 0.006 mg/L + 10%
Mercury @ pH 8.5
0.006 mg/L 0.006 mg/L + 10%
Toxaphene
0.015 mg/L 0.015 mg/L + 10%
Turbidity
10.8 NTU
*Based on the use of Cryptosporidium parvum oocysts
Operating Specifications
Capacity:
Pressure Requirement:
Temperature:
Flow rate:
Check for compliance with the state and local laws and regulations.
Note: While the testing was performed under standard laboratory conditions, actual performance may vary.
Must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Installation instructions, parts and service availability, and standard warranty are included with the product when
shipped. This drinking water system must be maintained according to manufacturer's instruction, including
replacement of filter cartridges.
Manufactured by: 3M Purification Inc.
400 Research Parkway
Meriden, CT 06770
NSF Specified
Avg %
Challenge
Reduction
Concentration
2.0 mg/L + 10%
97.5%
At least 10,000
98.9%
particles/mL
7
8
10
to 10
fibers/L;
>99%
fibers greater than
10µm in length
89.3%
Minimum 50,000
99.99%
cysts/L
99.3%
99.3%
97.8%
95.0%
88%
93.2%
11 + 1 NTU
98.7%
Certified for up to 750 gallons (2,838 L); up to nine months
20 - 120 psi (1.4 - 8.2 bar)
33-100
o
F (0.6 - 37.8
0.78 gpm (2.9 l/min.)
System tested and certified by NSF International
against Standard 42 for the reduction of chlorine taste
and odor, particulate Class I and Standard 53 for the
reduction of Lead, Lindane, Atrazine, Mercury,
Toxaphene, Cyst, Turbidity, and Abestos.
27
Average
Max Permissible
Product Water
Product Water
Concentrtation
Concentration
0.05 mg/L
N/A
143,333 pts/mL
N/A
<1 MF/L
N/A
0.001 mg/L
0.003 mg/L
1 cyst/L
N/A
0.001 mg/L
0.010 mg/L
0.001 mg/L
0.010 mg/L
0.00004 mg/L
0.0002 mg/L
0.0003 mg/L
0.002 mg/L
0.0007 mg/L
0.002 mg/L
0.001 mg/L
0.003 mg/L
0.153 NTU
0.5 NTU
o
C)
NSF
NSF Test
Reduction
Report
Requirements
> 50%
J-00056501
> 85%
J-00056506
> 99%
J-00056511
N/A
J-00056512
> 99.95%
J-00056513
N/A
J-00056515
N/A
J-00058784
N/A
J-00058969
N/A
J-00058785
N/A
J-00058783
N/A
J-00056531
N/A
J-00058972