Remote Control
Linkage
The throttle and choke control levers are provided with holes for optional cable
attachment.
1. Remove the two 6 mm special bolts from the control cover and remove the
control cover.
6 mm SPECIAL
BOLTS
CONTROL
COVER
.._ ,
2. The following illustrations show installation examples for a solid wire cable.
Do not use a braided wire cable.
It is necessary to loosen the throttle lever friction nut when operating the
throttle with a remote cable.
REMOTE THROTTLE
AND REMOTE CHOKE
5 mm SCREW
CHOKE
THROT
LEVER
FRICTION
NUT
6 mm SCREW
3. Reinstall the control cover.
Install the throttle cable or the choke cable to the control base, after guiding
the cable through the hole in the control cover.