APW Wyott HDCB-2436i Operating Instructions Manual

Heavy duty

Advertisement

Quick Links

MODELS: HDCB-2424i, HDCB-2436i, HDCB-2448i, HDCB-2460i, HDCB-2472i
Heavy Duty Charrock Gas Broilers
MODELS: HDCRB-2424i, HDCRB-2436i, HDCRB-2448i, HDCRB-2460i, HDCRB-2472i
Please complete this information and retain this manual for the life of the equipment. For
Warranty Service and/or Parts, this information is required.
Model Number
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance
can cause property damage, injury or death. Read the installation, operating and
maintenance instructions thoroughly before installing, or servicing this equipment.
WARNING: Instructions must be posted in a prominent location. All safety
precautions must be taken in the event the user smells gas. Safety information
can be obtained from your local gas supplier.
DALLAS:
1307 N. Watters Rd #180 • Allen, TX • 75013
Local: (972) 908-6100
Toll Free: (800) 431-2745
Parts/Service Fax: (214) 565-0976
INSTALLATION AND OPERATING INSTRUCTIONS
Heavy Duty Gas Char-Broilers
IMPORTANT FOR FUTURE REFERENCE
APW Wyott MANUFACTURING
&
Serial Number
CHEYENNE:
1938 Wyott Dr • Cheyenne, WY • 82007
Local: (307) 634-5801
Toll Free: (800) 752-0863
Parts/Service Fax: (214) 565-0976
1
 
Date Purchased
P/N 8822211 09/26/13

Advertisement

Table of Contents
loading

Summary of Contents for APW Wyott HDCB-2436i

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS   Heavy Duty Gas Char-Broilers MODELS: HDCB-2424i, HDCB-2436i, HDCB-2448i, HDCB-2460i, HDCB-2472i & Heavy Duty Charrock Gas Broilers MODELS: HDCRB-2424i, HDCRB-2436i, HDCRB-2448i, HDCRB-2460i, HDCRB-2472i IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or Parts, this information is required.
  • Page 2: Table Of Contents

    Before doing any maintenance or repair, contact APW Wyott Congratulations on your purchase of APW Wyott commercial cooking equipment. APW Wyott takes pride in the design and quality of our products. When used as intended and with proper care and maintenance, you will experience years of reliable operation from this equipment.
  • Page 3: Safety Precautions

    If you have questions concerning the installation, operation, maintenance or service of this product, write Technical Service Department APW Wyott, 1307 N Watters Rd # 180, Allen, TX 75013 SAFETY PRECAUTIONS DANGER: This symbol warns of imminent hazard which will result in serious injury or death.
  • Page 4: General Installation Instructions

    GENERAL INSTALLATION INSTRUCTIONS Ensure gas supply and gas type, as shown on unit nameplate agree. Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National Gas Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2 as applicable and in accordance with local codes.
  • Page 5: Specifications And Dimensions

    (MM) HOUR ('Mbar') 24" 34.339" 20,000 15.217" 80,000 HDCB-2424i (386.5) (23.4) (609.6) (872) (5.86) (12.4) 36" 34.339" 20,000 120,000 15.217" HDCB-2436i (914.4) (35.2) (386.5) (872) (5.86) (12.4) 48" 34.339" 20,000 160,000 15.217" HDCB-2448i (1219.2) (46.9) (386.5) (872) (5.86) (12.4) 60"...
  • Page 6: Conversion

    CONVERSION  Instructions are for conversion from Natural Gas to Propane (L.P.) on all models HDCRB & HDCB.  The conversion should be done before connecting the unit to the gas supply.  Units are shipped from the factory equipped for use on natural gas. Orifices necessary for LP (propane) are provided in a bag tied to the valve on the front panel.
  • Page 7: Lighting Instructions

    or grease which may accumulate around this cap. The openings must remain open for the regulator to function. Clean more often in a very greasy atmosphere. LIGHTING INSTRUCTIONS HDCB and HDCRB Broilers are furnished with either a pilot safety valve or a standing pilot (not available in the European Community).
  • Page 8  For first cooking, set the grates at maximum tilt position and preheat before broiling. You will have to experiment with knob settings and grate position for each particular item.  Keep the grease/water pan with sufficient water to cover the entire bottom. ...
  • Page 9: Operating Instructions

    OPERATING INSTRUCTIONS OPERATION: Turn the burners on about 15-20 minutes before cooking for preheating. Set the knobs to the desired flame height or temperature. Each valve will control the gas flow to the burner to bring that area of the unit up to the set temperature. If different temperature settings are to be used, adjoining areas should be set at progressively higher temperatures using the lowest temperatures on the outside burners.
  • Page 10: Cleaning/Maintenance

    CLEANING / MAINTENANCE INITIAL CLEANING: Prior to operating your new broiler, thoroughly wash the exterior with a mild detergent or soap solution. Do not use abrasive cleaners, since this might damage the cabinet finish. If the stainless steel surfaces become discolored, scrub by rubbing only in the direction of the finished grain. When the broiler is first heated, it will smoke until oil used in manufacturing, preservation and dust from storage and shipping are burned off.
  • Page 11: Service/Repair

    SERVICE / REPAIR NOTE: THIS APPLIANCE MUST ONLY BE SERVICED BY AN AUTHORIZED AGENT. NOTE: Parts protected by the manufacturer or his agent are not to be adjusted by the installer, unless the installer is an authorized service agent. TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE Heat does not come on when valve is turned...
  • Page 12 EXPLODED VIEWS (Domestic Version) HDCB & HDCRB - GAS CHAR BROILER...
  • Page 13 PARTS LIST (DOMESTIC VERSION) HDCB & HDCRB - GAS CHAR BROILER (Page 1 of 2) Quantity Item Description 21825020 Weldm't, Bullnose 21825120 Weldm't, Bullnose 21825220 Weldm't, Bullnose 21825320 Weldm't, Bullnose 21825420 Weldm't, Bullnose 21825433 Side, Firebox 21825022 Body, 24" Firebox Body, 36"...
  • Page 14 HDCB & HDCRB - GAS CHAR BROILER (Page2 of 2) Quantity Item Description 21825332 Panel, Back 60" 21825432 Panel, Back 72" 21829519 Panel, Control 24" 21829619 Panel, Control 36" 21829719 Panel, Control 48" Panel, Control 60" 21829819 21829919 Panel, Control 72" 21825028 Support, Rock Grate Rear 21825128...
  • Page 15 EXPLODED VIEWS (CE Version) HDCB & HDCRB - GAS CHAR BROILER...
  • Page 16 PARTS LIST (CE VERSION) HDCB & HDCRB - GAS CHAR BROILER (Page 1 of 2) Quantity Item Description 21825020 Weldm't, , Bullnose 21825120 Weldm't, , Bullnose 21825220 Weldm't, , Bullnose 21825320 Weldm't, , Bullnose 21825420 Weldm't, , Bullnose 21825433 Side, Firebox Face, 24"...
  • Page 17 HDCB & HDCRB - GAS CHAR BROILER (Page 2 of 3) Quantity Item Description Panel, Control 24" CE 21829541 Panel, Control 36" CE 21829641 21829741 Panel, Control 48" CE 21829841 Panel, Control 60" CE Panel, Control 72" CE 21829941 Support, Rock Grate Rear 21825028 Support, Rock Grate Rear 21825128...
  • Page 18 HDCB & HDCRB - GAS CHAR BROILER (Page 3 of 3) Quantity Item Description 8806070 Label, Delivery CE Gas Units (N/S) 8806075 Label, Packaging CE Units (N/S) 8806080 Label, CE Ventilation (N/S)
  • Page 19: Warranty

    APW Wyott's option or its Authorized Service Agency, it will be serviced on site or replaced. From day two through the conclusion of this warranty period, portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in-warranty repairs.