Fan; Specifications - Master 100000 BTU/Hr Owner's Manual

Portable forced air heaters
Table of Contents

Advertisement

Fan

IMPORTANT:
Remove fan
from motor shaft before
removing motor from heater.
The weight of the motor
resting on the fan could
damage the fan pitch.
1. Remove upper shell (see
page 10).
2. Use 1/8" allen wrench to
loosen setscrew which
holds fan to motor shaft.
3. Slip fan off motor shaft.
4. Clean fan using a soft cloth
moistened with kerosene or
solvent.
5. Dry fan thoroughly.
6. Replace fan on motor
shaft. Place fan hub flush
with end of motor shaft
(see Figure 25).
7. Place setscrew on flat of
shaft. Tighten setscrew
firmly (40-50 inch-pounds/
4.5-5.6 n-m).
8. Replace fan guard and
upper shell.

SPECIFICATIONS

101585
Setscrew
Figure 24 - Fan, Motor Shaft, and Setscrew Location
Output Rating (BTU/Hr)
Fuel
Fuel Tank Capacity
(U.S. Gal./Liters)
Fuel Consumption
(Gal. Per Hr./Liters Per Hr.)
Electric Requirements
Amperage (Normal Run)
Hot Air Output (CFM/CMM)
RPM
Motor
Shaft
Fan
Motor
Shaft
Setscrew
Figure 25 - Fan Cross Section
70,000
Use Only Kerosene or No. 1 Fuel Oil
5.0/18.9
.52/1.97
220 V/60 Hz (Same All Models)
2.0
250/7.1
3450
Fan
Flush
100,000
150,000
9.0/34.1
13.5/51.1
.78/2.95
1.10/4.16
2.0
2.0
490/13.9
500/14.2
3450
3450
15