Cleaning the Brake Rollers -
1
While pulling the ADF lever towards
you, lift up the ADF upper sheet
guide.
ADF Upper
Sheet Guide
ADF Release Lever
Cleaning the Feed Rollers -
Wipe the metal feed rollers using a lint free cloth moistened with cleaner F2. Wipe the rollers
thoroughly. If the rollers have black build up, feed reliability will be affected
Cleaning the Glass Surface -
1
Use your index fingers to lift both
ends of the removable sheet guide.
Lift right side first.
Cleaning the Glass Sheet Guide -
1
Push down on the Glass Sheet Guide tab to open.
Recommended Cleaning Cycle Every 300,000 Sheets
2
Pressing down on the upper part
of the Guide Plate with your
fingers, pull the plate towards
you to remove.
Guide Plate
Recommended Cleaning Cycle Every 300,000 Sheets
Feed Rollers
(in 12 locations)
Recommended Cleaning Cycle Every 200,000 Sheets
2
Shift the sheet guide to the left while
lifting up to remove.
Removable Sheet Guide
Recommended Cleaning Cycle Every 200,000 Sheets
Glass Sheet Guide
3
Lift the bail of the Brake Roller upwards
and release the lock. Pull the Brake
Roller forward to remove it. Wipe roller
surface using cleaning
paper moistened with
cleaner F1.
Pad Assy
Brake Roller
3
Wipe both sides of the glass
surface using a cleaning paper
moistened with cleaner F1.
2
Wipe Glass Sheet Guide using a
cleaning paper moistened with cleaner
Brake Roller
Bail
Glass Sheet Guide