VENT INSTALLATION
VENT INSTALLATION
VENT INSTALLATION:
The following venting instructions are provided as a general guideline. Always check with pipe manufacturer
Positioning The Fireplace:
The fireplace must be installed giving full consideration to the clearance and height requirements identified
1.
Bend out the four (4) nailing flanges located on the sides of the fireplace. For 5/8" drywall use the two (2) outer
most flanges. For _" drywall use the two (2) inner flanges.
2.
Slide the firebox into prepared framing or position fireplace in its final position and frame later. Be sure
fireplace is resting on a flat surface.
3.
Set unit level and plumb by checking the top and front of unit. Shim side-to-side and front-to-back as necessary.
4.
Anchor nailing flanges of the fireplace to the side-framing members using 8d nails or other suitable fasteners.
Venting Configuration:
This natural vent fireplace has been tested to use 8" Class B-Vent pipe
Vertical Venting Straight up (No Elbow):
Figure 6: Vertical Venting – Straight Up
WARNING
for venting requirements.
NOTE
in this manual.
WARNING
Never use 90 degree elbows
WARNING
10
Dim
Min
Max
V
14 feet
40 feet