Indoor Unit (Ras-13Gkp-Es2,Ras-13Nkp-As2); Outdoor Unit (Ras-13Ga-Es2,Ras-13N2A-As2) - Toshiba RAS-13GKHP-ES2 Service Manual

Air conditioner split wall type
Table of Contents

Advertisement

4-3. Indoor Unit (RAS-13GKP-ES2, RAS-13NKP-AS2)
No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Transformer
4
Microcontroller unit (IC30)
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Bridge rectifier (DB50)
8
Capacitor (C50)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Louver motor
12
Relay (Comp., RY01)
4-4. Outdoor Unit (RAS-13GA-ES2, RAS-13N2A-AS2)
No.
Parts name
1
Compressor
Fan motor
2
(for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Type
SKF- 220-20-4A-1
TT-10
TMP87CM40AN
*SS11V-06270
KBP06M/51
PF1E222MNN1625
BET6.3A
TND15G561K
MP24Z
DI1U
Type
Output (Rated) 1100W, 2poles, 1 phase, 220 − 240V, 50Hz
PA150X2C-4FT
Winding resistance (Ω)
(at 20°C)
Output (Rated) 30W, 6poles, 1 phase, 220 − 240V, 50Hz
WLF-240-30A
Winding resistance (Ω)
(at 20°C)
AC 450V, 1.5µF
DS451155NPQB
AC 440V, 30µF
RS44B306U0214S
− 12 −
FILE NO. SVM-06027
Specifications
°
AC Motor with 150 C thermo fuse
W
°
10k at 25 C
W
°
10k at 25 C
27mH, 600mA
1.5A, 600 V
2200mF, 25 V
T6.3A, 250VAC
560 V
12VDC
Rating 25A/AC250 V, 3~48VDC
Specifications
C-R
2.35
Red-Black
237
C-S
3.22
White-Black
380

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents