Download Print this page

Advertisement

Quick Links

一.General
.General
.General ......................................................
二.Open-Package
.Open-Package
.Open-Package Inspection
三. . . Safety
Safety
Note
Safety Note
Note ...................................................
四. . . Front
Front
Panel&
Front Panel&
Panel& Button
五. . . Other
Other
Functions
Other Functions
Functions.............................................
六.Property
.Property
.Property......................................................
七.Instrument
.Instrument
.Instrument Maintenance
八.Fault
.Fault
Elimination
.Fault Elimination
Elimination..........................................
VICTOR
VICTOR
VICTOR 81A/81B
Digital
Multimeter

Digital Multimeter

Digital
Multimeter
Operation
Operation Manual
Operation
......................................................
...................................................... 1 1 1
Inspection
Inspection.................................
................................................... 2 2 2
...................................................
Button
Button Function
.............................................5 5 5
.............................................
......................................................
...................................................... 5 5 5
Maintenance
Maintenance.................................
.......................................... 1 1 1 6 6 6
..........................................
81A/81B
81A/81B
Manual
Manual
.................................1 1 1
.................................
Function
Description
Function Description
Description ............
.................................1 1 1 5 5 5
.................................
............4 4 4
............

Advertisement

loading

Summary of Contents for Victor 81A

  • Page 1: Digital Multimeter

    VICTOR 81A/81B VICTOR VICTOR 81A/81B 81A/81B Digital Multimeter Digital Digital Multimeter Multimeter Operation Manual Operation Operation Manual Manual 一.General .General ……………………………………………… ……………………………………………… 1 1 1 .General ……………………………………………… 二.Open-Package .Open-Package Inspection …………………………… ……………………………1 1 1 .Open-Package Inspection Inspection…………………………… 三. . . Safety...
  • Page 2 一、General General General VICTOR 81A/B is a steady performance, high security 3 1/2 digital multimeter. It uses LCD with 18.9mm high figure to make the reading clear. The digital multimeter has the function of measuring ACV, DCV, ACA, DCA, Resistance, Celsius & Fahrenheit Temperature, Diode, Continuity. The instrument also has the features of Unit Symbol Display, Auto/Manual Range Selection, Auto Power Offer and Alarm Function.
  • Page 3 三、Safety Safety Note Safety Note Note The instrument is designed according to IEC1010 standard (safety standard issued by International Electro technical Committee). Please read the following before operation. Caution to avoid the electric shock when measuring voltage higher than 36V DC, 25AC, current higher than 10mA, AC power line with inductance load and AC power line during the power fluctuation.
  • Page 4 output socket or lead clamp with ground potential. Usually use the dry cloth, rubber overshoes, rubber cushion and other insulated materials to keep the body isolated with the ground. Do not store and use the instrument in high humility, high temperature, combustible, explosive and strong magnetic places.
  • Page 5 Do not try to modify the inner circuit at will to avoid damaging the instrument and endangering the safety of the users. 15. Safety Symbol Description: Warning! Warning! Warning! High Voltage Voltage! ! ! High High Voltage Dangerous! Dangerous! Dangerous! DCA &...
  • Page 6 Range mode, press the button once, the range is switched to the higher one, press the button again to switch the range to the lowest one when measuring the highest range, the cycle is in proper order from low to high.
  • Page 7 1-3.Measuring Method:Dual integral A/D converter 1-4.Sampling Rage:Approx. 3 times / sec. 1-5.Over range Indication:Display“OL” 1-6.Low Battery Indication:“ ”symbol appearance; 1-7.Operation Environment: ( 0~40)℃,Relative Humidity: <80% ; 1-8.Storage Environment: ( 0~50)℃,Relative Humidity: <80% ; 1-9.Power:2pcs 1.5V batteries(“AAA”7# battery) ; 1-10.Dimension(size) : 145×74×36mm 1-11.Weight:Approx.
  • Page 8 2-3.Technic Specification (note“*”indicates the instrument does not have the range) 2-3-1.DCV 2-3-1.DCV 2-3-1.DCV V V V Insert the red and black test leads separately to and COM input terminals. Turn the knob switch to Range, press “SELECT” button to switch to DCV measurement mode.
  • Page 9 Accuracy VICTOR81A VICTOR81B Resolution Range 200mV 100uV ±(0.5%+4d) 10mV 200V 100mA 600V ±(1.0%+4d) Input Impedance: >10MΩ at Range 200mV , 40MΩ at other Ranges。 Overload Protection:600V AC or 600V AC Peak Value; 2-3-2. 2-3-2. 2-3-2. ACV V V V 1. Insert the red and black test leads separately to and COM input terminals.
  • Page 10 tested voltage value has exceeded the present range limit, please select the higher range to complete the measurement. 2. Do not measure the voltage higher than 600V. Otherwise, there is the danger to damage the instrument. 3. When measuring the high voltage, caution to avoid the body touches the high voltage.
  • Page 11 Note Note Note: 1. Firstly users should select the auto range mode, if users had no idea about the range of tested current, and then select the proper range based on displaying value. 2. If “OL” is displayed on LCD, it indicates the tested current value has exceeded the present range limit, please select the higher range to complete the measurement.
  • Page 12 ACA measurement mode. Connect the test leads to the tested point in series, the current value and polarity of point connected by red lead will be displayed on LCD simultaneously. 3. Press “RANGE” button to select auto or manual range mode. Note Note Note:...
  • Page 13 Frequency Response:10A Range (50~200)Hz, 2-3-5.Resistance(Ω Ω Ω ) 2-3-5.Resistance 2-3-5.Resistance V V V 1. Insert the red and black test leads separately to and COM input terminals. 2. Turn the knob switch to “Ω Ω Ω ” Range, connect the test leads cross with the tested resistor.
  • Page 14 Accuracy VICTOR81 VICTOR81 Resolutio Range 200Ω ±(0.8%+5d) 0.1Ω 2kΩ 1Ω 20kΩ ±(0.8%+4d) 10Ω 200kΩ 100Ω 2MΩ 1kΩ 20MΩ ±(1.2%+10d) 10kΩ Open Voltage circuit:Less than 200mV; Overload Protection:250V DC or AC Peak Value; Note:When measuring at Range 200Ω, please short-circuit the test leads at first to test the wire resistance, and then deduct it from the actual resistance.
  • Page 15 6. Press “SELECT” button to select the Continuity measurement mode. 7. Insert test leads to two points of tested circuit, if the inner buzzer sounds, the resistance is less than 50Ω. Range Display Test Condition Forward DC Current is 0.5mA , Forward Voltage Drop of Approx.
  • Page 16 Accuracy Accuracy Resolution Range <400℃±(1.0%+5d) (-20~1000)℃ 1℃ ≥400℃±(1.5%+15d) (0~1832)℉ ±(1.5%+15d) 1℉ Sensor:K Type Thermocouple (banana plug)。 CAUTION:DO NOT INPUT VOLTAGE AT THIS RANGE! 七、Instrument Instrument Maintenance Instrument Maintenance Maintenance Instrument is a high accuracy instrument, please don’t modify the circuit. 1.Keep the instrument away from water, dust and shock.
  • Page 17 2. Don’t measuring the voltage at current, resistance, diode and continuity range. 3.Don’t use the instrument when the battery isn’t installed or the back case isn’t firm. 4. When replacing battery or fuse, please take away the test leads from the measured point and power off at first.

This manual is also suitable for:

81b