Download Print this page

Customer Service - Pentair CP-30 User Manual

Pool-spa switching system

Advertisement

Customer Service

If you have questions about ordering Pentair Pool Products replacement
parts, and pool products, please use the following contact information.
Customer Service (8 A.M. to 5 P.M. Pacific Time)
Phone: (800) 831-7133 (press 3 in voice mail)
Fax: (800) 284-4151
Technical Support for Pentair Pool Products
Sanford, North Carolina (8 A.M. to 5 P.M. Eastern Time)
Phone: (919) 774-4151 (press 1 in voice mail)
Fax: (919) 776-0562
Moorpark, California (8 A.M. to 5 P.M. Pacific Time)
Phone: (805) 523-2400 (Ext. 6502)
Fax: (805) 530-0194
Web site
visit www.pentairpool.com to find information about Pentair Pool Products
© 2004 Pentair Pool Products
1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400
All rights reserved. Information in this document is subject to change without notice.
Trademarks and Disclaimers. Compool is a registered trademarks of Pentair Pool Products.
Other trademarks and trade names may be used in this document to refer to either the entities
claiming the marks and names or their products. Pentair Pool Products disclaims any proprietary
interest in trademarks and trade names other than its own.
2
MAINTENANCE
WINTERIZING THE SYSTEM :
During the winter season, it is possible to partially drain your swimming pool and
disable the pool equipment, but still be able to use your spa.
Consult a qualified service company to drain the pool, and protect the plumbing
from freeze damage.
The following procedures will disable the pool equipment :
1. At the Remote control, turn the SPA Switch to "SPA" position.
2. Unplug cables from Valve Actuators.
3. At the Remote Control, turn the SPA Switch back to "POOL" position.
4. At the Power Center, turn FILTER PUMP Service Switch to the "OFF" position.
NOTE : If daily spa filtration is required, the FILTER TIMER Dial should be
programmed accordingly.
A Recirculating Freeze Sensor (model FPS-C) may have been added to your
system. It protects the plumbing and equipment from possible freeze damage,
by running the filter pump whenever the temperature falls to approximately 41° F.
In this instance, it will not be necessary to have the swimming pool drained. It is,
however, recommended that all freeze sensors be tested by an authorized Service-
person before the onset of the winter season.
Testing can be accomplished by placing sensor in a glass of ice water, and
turning FILTER PUMP Service Switch to the "OFF" position. If the sensor is
functioning correctly, the filter pump should turn on within ten minutes.
Repeat this test for any Auxiliary Freeze Sensors (model FPS-AUX) which
may have been added for the jet pump or auxiliary equipment.
CLEANING THE SPA :
It is possible to empty your spa for cleaning and maintenance purposes, and
then to refill with clean water from your pool.
At the Power Center :
1. Set the SPA SERVICE Switch to "DRAIN" position.
2. Set the FILTER PUMP Service Switch to "ON" position. The spa will begin
to drain into the pool.
3. Before the spa has drained completely, set the FILTER PUMP Service Switch
to "OFF" position. Do not drain the spa completely or prime will be lost.
4. When cleaning or spa maintenance is complete, set the SPA SERVICE
Switch to "FILL" position and the FILTER PUMP Service Switch to "ON"
position. The spa will begin to fill with clean water from the pool.
5. When water level in the spa has returned to normal, return the SPA SERVICE
Switch to "AUTO" position and the FILTER PUMP Service Switch to "TIMER"
position.
CAUTION : Do NOT leave equipment unattended when draining or filling the spa.