Product Repair & Service.
7.0 
7.1 
  I t is recommended that a periodic visual and operation evaluation is carried of the Positioner Monitor at least once a 
year or every 1 million cycles. If the shaft requires lubrication then a suitable (NLGI 2) rated grease such as Rocol 
Sapphire Lo Temp 2 should be used. Please note that if any other lubricant other than Rocol Sapphire Lo Temp 2 then 
is shall be compatible with the shaft 'O'ring material. 
 
7.2 
  I nspection of this product shall be carried out by periodically by suitably trained personnel in accordance with the 
applicable code of practice such as 60079‐17 to ensure that it is maintained in a satisfactory condition. 
 
7.3 
The equipment is not intended to be repaired by the user. The repair of this equipment is to be carried out by the 
manufacturer, or their approved agents, in accordance with the applicable code of practice such as 60079‐19. 
 
7.4 
The equipment contained within this product can be replaced with like for like parts / assemblies ONLY. 
 
7.5 
The certification of this product has been approved based on the material of construction as per the drawings listed 
in the schedule within this certificate. Any replacement parts that are not made in accordance to the listed drawing 
will invalidate the approval / certification. 
 
7.6 
Replacement parts must be purchased through Westlock Controls or via an approved Westlock Controls distributor.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
280 N. MIDLAND AVE., STE 258, SADDLE BROOK, NJ 07663 TEL: 201-794-7650 FAX: 201-794-0913
1/20/2016
  
PENTAIR VALVES & CONTROLS.
TECHUK-95 REV 1 ECN#12787-E