Operation Details

8) Airflow Direction Control
Airflow Direction Auto-Control
• When set a Airflow Direction Auto-Control with
remote control, the louver swings up and down as
shown in the diagram.
• The louver does not swing when the Indoor Fan
stops during operation.
• When stopped with remote control, the discharge
vent is closed with the louver.
* 1 There is no swinging while indoor fan is stopped during Cooling and Soft Dry operation.
* 2 In Air Circulation operation, when the intake air temperature reaches set temperature, the airflow direction is
changed from upper limit to lower limit. When the intake air temperature falls to 2°C lower than set temperature,
the airflow direction is changed from lower limit to upper limit.
Airflow Direction Manual Control
• When the airflow direction set button is pressed,
the automatic airflow is released and the airflow
direction louver move up and down in the range
shown in the diagram.
The louver can be stopped by releasing the button
at the desired louver position.
• When the remote control is used to stop the opera-
tion, the discharge vent is closed with airflow
direction louver.
9) Delay ON Timer Control
• When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time,
so that the room will reach nearly to the set temperature by the desired time.
• For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
• For Automatic mode, the indoor fan will operate at SLo speed for 20 seconds 15 minutes before the set time to detect
the intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
* The left and right airflow direction louvers can be
adjusted manually.
The louver can be adjusted with in a range
"Airflow Direction Setting Button" is pressed.
* The left and right airflow direction louvers can be
adjusted manually.
– 19 –
Horizontal
Upper limit
34°
Swing up and down
57°
Lower limit for
Cooling Mode and
Soft Dry Mode
Lower limit for Air Circulation Mode
Horizontal
Upper limit
34°
57°
Lower limit for
Cooling Mode and
Soft Dry Mode
Lower limit for Air Circulation Mode