Operation Details
5) Sleep Mode Auto Operation
Cooling or Soft Dry Operation
When you press the SLEEP Mode, the following move-
ment will start to avoid overcooling.
• When the room temperature reaches the setting
temperature or after 1 hour of operation, sleep shift
operation starts and the airflow volume will automati-
cally change to low.
• The setting temperature will be risen by 0.5°C at the
start of operation and by 0.5°C one hour later.
• The operation will stop after 8 hours.
6) Auto Restart Control
• If there is a power failure, operation will be automatically restarted when the power is resumed.
It will start with previous operation mode and airflow direction.
(Time Delay Safety Control is valid)
• Auto Restart Control is not available when Timer or Sleep Mode is set.
• This control can be omitted by cutting the jumper wire J2. (Refer Circuit Diagram)
7) Indoor Fan Speed Control
• Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the
table.
• Manual Fan Speed Control
Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection
button.
Fan Speed
Cooling
Soft Dry
Air Circulation
* SLo: Indoor Fan rotates at 4-second intervals at Low speed.
Hi
t
Manual
t
Automatic
Approx. 0.5°C increase
TEMP.
Approx. 0.5°C increase
0 – 1 hour
Sleep Operation starts
Me
Lo
t
t
t
t
t
– 18 –
CS-C181KE
After approx.
8 hours stops
1 hour
automatically
Stop
SLo
t
TIME
t