Wiring Diagram - Panasonic CS-C181KE Service Manual

Room air conditioners
Table of Contents

Advertisement

Wiring Diagram

CS-C181KE / CU-C181KE
CS-C241KE / CU-C241KE
220-240V, 50Hz
POWER SUPPLY CORD
BRW
ELECTRONIC CONTROLLER
BLU
2
4
1
3
CN-FM(GRN)
RY-C
P
FUSE
(T 3.15A L 250V)
L
CN-FUSE 1
THERMAL
FUSE
(113°C)
WHT
WHT
BLK
YEL/GRN
INDOOR UNIT
1 2
TERMINAL
OUTDOOR UNIT
1
2
TERMINAL
BLU
YEL
BLU
CAPACITOR
RED
BLU
COMPRESSOR
YEL
WIRELESS
REMOTE
CONTROL
REMOTE
CONTROL No.
B
A
FAN
MOTOR
1
3
5
7
9
T(BLK)
T(BLK)
RED
RED
TRANSFORMER
1
3
CN-FUSE(BLU)
RED
RED
YEL/GRN
THERMAL
FUSE
(102°C)
YEL/GRN
C
THERMOSTAT
H
L
FAN MOTOR
BLUE
ORG BRW
(BLU)
TRADE MARK
COMPRESSOR TERMINAL
FUSE
T3.15A
BLU
L250V
RED
CAPACITOR
BLU
ELECTRONIC
CONTROLLER
RECEIVER
+
DISPLAY LAMP
CN-DISP (WHT)
6
5
4
3
2
1
WHT
1
WHT
2
WHT
3
WHT
4
WHT
5
WHT
6
PUMP DOWN SW
(TEST RUN)
AUTO SW
BRW
RED
MOTOR
ORG
LOUVER
YEL
PNK
SENSOR
(AIR TEMP.)
SENSOR
(PIPE TEMP.)
Resistance of Indoor Fan Motor Windings
CONNECTION
YELLOW - BLUE
YELLOW - BROWN
BROWN - ORANGE
ORANGE - RED
Resistance of Outdoor Fan Motor Windings
YELLOW
(YEL)
CONNECTION
BLUE - BROWN
RED
BROWN - ORANGE
(RED)
RED - BROWN
J9890708
Resistance of Compressor Windings
CS/CU-C181KE
C181KE07.DWG
CONNECTION
– 12 –
REMARKS:
BLU
: BLUE
BRW
: BROWN
BLK
: BLACK
WHT
: WHITE
RED
: RED
ORG
: ORANGE
PNK
: PINK
YEL/GRN : YELLOW/
GREEN
GRY
: GRAY
CS-C181KE
CWA92270 (Ω)
357.0
41.7
63.1
249.6
CU-C181KE
CWA92272 (Ω)
79.5
65.1
70.8
CU-C181KE
2JS350D3AA02 (Ω)
0.980
C-R
3.929
C-S
CS-C181KE
CS-C241KE
CWA92287 (Ω)
176.0
70.4
71.7
148.7
CU-C241KE
CWA92271 (Ω)
46.8
64.6
73.7
CU-C241KE
2JS464D3AA02 (Ω)
0.888
2.328