Battery Care - Winnebago Era Touring coach Owner's Manual

Table of Contents

Advertisement

SECTION 6 –
ELECTRICAL

BATTERY CARE

Lead-acid type batteries are electro-chemical
devices for storing and releasing electrical
charge. As such, they are simply an electrical
reservoir, not an electrical source. As soon as
energy is removed from the battery, it should be
replaced by the engine alternator or the coach
converter system.
If a battery sits unused for 30 days or more,
especially during warm weather, it can develop a
deposit of sulfate crystals on the metal plates
inside the battery. This condition is called
"sulfating" and prevents the battery from either
releasing or accepting a charge. If this condition
occurs, the battery must be replaced.
If a battery does not contain at least 80%
charge during freezing temperatures, the
electrolyte can freeze and crack the battery case.
The two best defenses against sulfating
and insufficient charge are to:
1. Turn off the House/Coach Battery Disconnect
switch to avoid parasitic discharge (the trickle
discharge caused by directly connected
components like propane gas detectors or
digital clock displays, etc.)
2. Check the battery and recharge as necessary at
least once a month during long storage
periods. Turn the House/Coach Battery
Disconnect switch off to avoid electrical
arcing when attaching or detaching charger
clamps.
NOTICE
Disconnect batteries before connecting
external charging equipment to avoid
damage to sensitive electronic
components.
6-8
WA RNING
This vehicle, like other vehicles, may
contain small amounts of one or more
substances which are listed by the state
of California for causing cancer or
reproductive toxicity.
WA RNING
California Proposition 65 Warning:
Battery posts, terminals, and related
accessories contain lead and lead
compounds, chemicals known to the
state of California to cause cancer and
reproductive harm. Wash hands after
handling.
NOTE: Do not leave the shoreline plugged in
during storage. Follow regular battery
inspection and maintenance.
Further precautions are:
Check the state of charge periodically to avoid
discharge or sulfating.
To ensure that the battery will always accept
and hold a charge, follow these simple
maintenance practices:
Make sure the batteries always remain
securely clamped in the battery tray.
Make sure battery cable clamps are tight on
the terminal posts and are free of corrosion.
Neutralize corrosion buildup or acid film on
top of battery by washing with a baking soda/
water solution. Rinse with clear water.
NOTE: Make sure vent caps are on securely to
prevent baking soda solution from
entering the battery and contaminating
the electrolyte fluid.