Accessories - Rheem RGPS series Technical Manual

Upflow/horizontal gas furnace

Advertisement

INTERNAL FILTER RACK FOR BOTTOM
OR SIDE RETURN: RXGF-DA*
Each order contains (1) one box of 10 filter racks supplied without
filters.
*Filters available through PROSTOCK
SIDE RETURN FILTER RACK: RXGF-CA
BOTTOM RETURN FILTER RACK FOR
UPFLOW APPLICATION: RXGF-CB
FILTER RACK FILTER SIZES† INCHES [mm]
MODEL
RGPS-
05, 07, 10EA
10EBRGR & 10EBRJR
12, 15
†Filter racks are shipped without filters.
A 1" [25.4 mm] filter may be used.
*Designates "E" or "N".
RXPF-F01 and F02
FOSSIL FUEL KIT—is for use with Rheem Value Series Heat Pumps
and air furnaces. RXPF-F02 meets TVA requirements.
RXGP-F03
TWINNING KIT—is for parallel operation requirements.
THE RXGR-C24B MUST ONLY BE INSTALLED ON THE SIDE
OPPOSITE THE GAS AND ELECTRICAL CONNECTIONS.
®
.
RXGF-CA
(SIDE)
15
3
/
x 25
4
[400 x 635]
15
3
/
x 25
4
[400 x 635]
15
3
/
x 25
4
[400 x 635]
ACCESSORY RETURN
AIR CABINETS
Return Air Cabinets may
be installed on either side
application except RXGR-C24B
(side application must be
on side opposite gas and
electrical connections).
RETURN AIR CABINETS
RXGR-C14B
RXGR-C17B
RXGR-C21B
RXGR-C24B
WARNING: IMPORTANT NOTICE
A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS
INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD
CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND
CREATE POTENTIALLY HAZARDOUS CONDITIONS.
FURNACE
SOLID BOTTOM
WIDTH
KIT NO.
IN. [mm]
14
1
/
[356]
RXGB-D14
2
17
1
/
[445]
RXGB-D17
2
21
1
/
[533]
RXGB-D21
2
24
1
/
[622]
RXGB-D24
2
FOR HIGH ALTITUDES:
OPTION CODE FOR HIGH ALTITUDE: U.S. & Canada
None required for high altitudes.
HIGH ALTITUDE CONVERSION KITS: U.S. & Canada
None required for high altitudes.
80+ HIGH ALTITUDE INSTRUCTIONS
CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines
when converting for high altitudes.
High altitude option codes are not required for these models.
However, the burner orifice size needs to be recalculated and verified
at elevations above 2000 ft. See Installation Instructions for more
information.
NOTE: For Canadian installations only, an optional derate (manifold
gas pressure reduction) method may be used to adjust the
furnace for altitude. See Installation Instructions for more
information. This optional method may NOT be used for U.S.
installations.
[ ] Designates Metric Conversions

Accessories

Air
RGPS Series
A
FILTER SIZE
IN. [mm]
IN. [mm]
14
1
/
[356]
(2) 12 x 16 [305 x 406]
4
17
1
/
[445]
(2) 12 x 16 [305 x 406]
2
21
1
/
[533]
(2) 20 x 16 [508 x 406]
4
24
1
/
[622]
(2) 24 x 16 [610 x 406]
2
BASE
BASE
PLATE SIZE
PLATE NO.
IN. [mm]
AE-61874-01
11
5
/
x 23
9
/
[295 x 598]
8
16
AE-61874-02
15
1
/
x 23
9
/
[384 x 598]
8
16
AE-61874-03
18
5
/
x 23
9
/
[473 x 598]
8
16
AE-61874-04
25
5
/
x 23
9
/
[651 x 598]
8
16