Accessories; Field Installed Option Accessories; Electronic Air Cleaner; Humidifier - Rheem 801T Series Installation Instructions Manual

Upflow/horizontal single stage gas furnaces with constant-torque air circulation blower
Table of Contents

Advertisement

ACCESSORIES

FIELD INSTALLED OPTIONAL ACCESSORIES

ELECTRONIC AIR CLEANER

Line voltage power can be supplied from the terminal labeled
"EAC" and a line voltage neutral terminal on the control board .
This will power the electronic air cleaner whenever the circulat-
ing air blower is in operation .

HUMIDIFIER

Line voltage power is supplied from the terminal labeled "HUM"
to a line voltage neutral terminal on the control board . This will
power the humidifier whenever the induced draft motor is ener-
gized .
NOTE: Maximum current – 1 .0 amps for each option (humidifier
or electronic air cleaner) .
RXGW-C01 4-INCH FLUE ADAPTER
(See Figure 26)
Refer to "Venting" section of this manual for more information .

See National Fuel Gas Code for sizing options .

FIGURE 26
30

1 . STANDARD 3" FLUE CONNECTION

1. STANDARD 3" FLUE CONNECTION.

2 . 4" ADAPTER OPTIONAL

2. 4" ADAPTER
SEE NATIONAL FUEL GAS CODE FOR SIZING OPTIONS
SEE NATIONAL FUEL GAS CODE FOR SIZING OPTIONS
1.
2.
ST-A1220-27-00
ST-A1220-27
FILTERS
(See Figure 27)
Keep filters clean at all times . A filter is not provided with the
furnace, but one must be field-supplied and installed .
It is recommended to replace the furnace filter periodically to
maintain optimum furnace performance .

RXGW-B01 CHIMNEY ADAPTER

IMPORTANT: CHIMNEY ADAPTER IS CERTIFIED FOR USE
ON 80% SINGLE STAGE CONSTANT TORQUE MODELS.
This appliance is CSA certified for use with RXGW-B01 Chimney
Adapter . Refer to Kit Installation Instructions 92-101682-01 .

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents