ELECTRONIC AIR CLEANER
Line voltage power can be supplied from the terminal la-
beled "EAC" and a line voltage neutral terminal on the con-
trol board. This will power the electronic air cleaner
whenever the circulating air blower is in operation.
HUMIDIFIER
Line voltage power is supplied from the terminal labeled
"HUM" to a line voltage neutral terminal on the control
board. This will power the humidifier whenever the burner
is on and the circulating air blower is operating in the heat-
ing mode.
NOTE: Maximum current – 1.0 amps for each option (hu-
midifier or electronic air cleaner).
LP GAS CONVERSION KITS
RXGJ-FP38 Universal: All Valves
RXGJ-FP36 White Rodgers Valve
RXGJ-FP33 Honeywell Valve
78
FILTERS
(See Figure 43)
Keep filters clean at all times. A filter is not provided
with the furnace, but one must be field-supplied and
installed.
It is recommended to replace the furnace filter periodically
to maintain optimum furnace performance.