5. OPTIONS

5.1 Acoustic signals
The acoustic signals operate when the
appliance has a malfunction and it is not
possible to deactivate them.
There is also an acoustic signal that oper-
ates when the programme is completed.
By default, this acoustic signal is off, but it
is possible to activate it.
How to activate the acoustic signal
for the end of programme
1. Press the on/off button to activate the
appliance.
2. If necessary, do the Reset function.
3. Press and hold Program until the pro-
gramme indicator
flash and the programme indicator
4. Press immediately Program.
• The programme indicator
comes on with fixed light.
The programme indicator
starts to flash.

6. BEFORE FIRST USE

1. Make sure that the set level of the wa-
ter softener agrees with the water
hardness in your area. If not, adjust
the water softener. Contact your local
water authority to know the water
hardness in your area.
2. Fill the salt container.

6.1 Adjusting the water softener

German
degrees
(°dH)
47 - 50
43 - 46
37 - 42
29 - 36
starts to
comes on with fixed light.
Water hardness
French
degrees
(°fH)
84 - 90
76 - 83
65 - 75
51 - 64
5. Wait until the programme indicator
cator
6. Press Program. The end indicator
comes on. The acoustic signal for the
end of programme is activated.
7. Press the on/off button to deactivate
the appliance and to confirm the set-
ting.
How to deactivate again the acoustic
signal for the end of programme
1. Refer to "How to activate the acoustic
signal for the end of programme" and
follow the procedure from step (1) to
step (5). The end indicator is on.
2. Press Program. The end indicator
goes off. The acoustic signal for the
end of programme is deactivated.
3. Press the on/off button to deactivate
the appliance and to confirm the set-
ting.
3. Fill the rinse aid dispenser.
4. Open the water tap.
5. Processing residues can stay in the
appliance. Start a programme to re-
move them. Do not use detergent and
do not load the baskets.
mmol/l
Clarke
degrees
8.4. - 9.0
58 - 63
7.6 - 8.3
53 - 57
6.5 - 7.5
46 - 52
5.1 - 6.4
36 - 45
ENGLISH
goes off. The programme indi-
continues to flash.
Water softener
adjustment
Level
10
9
8
7
7