cycles with an interval of 3 seconds between each cycle. After 3 alarm cycles, the system will remain in the
armed mode but the ignition sensor will be bypassed until the ignition is turned off.
F. Alarm Disable:
a. The system will remain in armed mode after the 30-second alarm time.
b. During the alarm being triggered, press button (2) once, the system will disarm. The siren will chirp 4 times,
the immobiliser will turn off, the indicator lights will flash three times, doors unlock (if connected) and the LED
will flash the trigger memories.
3.8 Boot Release
With the alarm armed or disarmed pressing button (3) for over 2 seconds will operate the boot release (where
fitted).
3.9 Panic Mode
A. When the system is armed, press button (1) for over 3 seconds, 3 seconds later the siren will sound for 30
seconds, indicator lights will flash for 30 seconds and the LED flashes rapidly. The system will remain in armed
mode.
B. When the system is disarmed, press button (2) for over 3 seconds, the system will be armed. 3 seconds
later, the siren will sound for 30 seconds, indicator lights flash for 30 seconds and the LED flashes rapidly. The
system will remain in armed mode.
C. When the system is armed, press button (4) once, the siren will sound for 30 seconds, the lights will flash
for 30 seconds and the LED will flash rapidly. The system will remain armed.
D. When the system is disarmed, press button (4) once, the alarm will sound for 30 seconds and enter armed
mode immobiliser will turn on, doors will be locked (if connected), indicator lights flash for 30 seconds and the
LED flashes rapidly. The system will remain armed.
3.10 Channel 3 Output
A. If channel 3 output is programmed as enabled: After the system is armed, the system will send a
30-second signal to the channel 3 output. This can be used for control of total closure on those vehicles with
this feature.
B. If channel 3 output is programmed as disabled: After the system is armed, the system will not send any
signals for channel 3 output automatically after arming but by pressing button (3) then hold button (1), the
system will send a 30-second signals to the channel 3 output.
3.11 Ignition Mode
*if C2-3 connected to brake light:
A. If the ignition door lock/unlock is programmed as disabled (Footbrake lock)
*When the system is disarmed and the ignition is on, if all doors are closed properly, the doors will be locked
(if connected) when the footbrake pedal is pressed. Once all doors are locked, depressing footbrake pedal
will not activate door locks.
*If any or all doors are not closed properly, depressing the footbrake pedal will not activate door locks.
*When the system is disarmed and the ignition is on, the footbrake lock will be activated once after the doors
are opened and closed doors the footbrake pedal pressed.
*When the ignition is switched off the doors will be unlocked immediately.
B. If the ignition door lock/unlock is programmed as enabled (Ignition door lock)
*When the system is disarmed, after switching the ignition on, doors will be locked after 3 seconds if all doors
are closed properly.
*When the ignition is switched off the doors will be unlocked immediately.
C. When under the ignition mode, pressing button (2) once will also control door lock/unlock.
*if C2-3 NOT connected to brake light:
Need help?