Upflow With Left Side Vent - Rheem R95P Installation Instructions Manual

(-)95p series
Table of Contents

Advertisement

UPFLOW LEFT VENT
FROM PARTS BAG (PROVIDED W/UNIT)
BULKHEAD
INTAKE
COUPLING
COUPLING
W/ NUT
TOOLS/MATERIALS NEEDED:
PLIERS
ELECTRIC DRILL
FLAT HEAD SCREWDRIVER
1/8" DRILL BIT
NOTE: THESE CONVERSION INSTRUCTIONS ARE INTENTIONALLY GENERIC, SOME PARTS MAY BE DIFFERENT IN YOUR FURNACE
1
1c
1a
1b
DISCARD
1a - REMOVE FLUE TRANSITION, TRANSITION COUPLING, AND ELBOW.
(NOTE: REMOVE INDUCER COUPLING W/ELBOW FOR EASIER REMOVAL).
1b - REMOVE 3-3/8" FLUSH MOUNT PLUG FROM JACKET - DISCARD.
1c - RELOCATE 2-3/8" FLUSH MOUNT PLUG FROM JACKET TO TOP PLATE.
SEE CRITICAL HOSE CLAMP LOCATION NOTE
3
IN THE GENERAL COVERSION INSTRUCTIONS.
DRILL 1/8"
DISCARD
OPTION DRAIN LEFT
DETERMINE RIGHT OR LEFT DRAIN OPTION.
LOCATE 7/8" HOLE IN JACKET SIDE.
REMOVE PLUG - DISCARD.
DRILL (2)
ø
1/8" HOLES FOR THE BULKHEAD COUPLING.
PARTS NEEDED:
(X2)
(X2)
HOSE
#8 X 1/2"
CLAMP
SCREW
TUBE C
5/16 HEX HEAD DRIVER
1/4" HEX HEAD DRIVER
FLUE TRANSITION
(DISCARD)
TRANSITION
COUPLING
(DISCARD)
ELBOW
(DISCARD)
IDB COUPLING
(RETAIN)
DRILL 1/8"
OPTION DRAIN RIGHT
FROM CONVERSION KIT RXGY-CK
2-5/8" FLUSH
2-3/8" PIPE
MOUNT PLUG
GROMMET
TUBING CUTTER
2
2-5/8"
2a
2b
2c
2a - INSTALL 2-5/8" FLUSH MOUNT PLUG IN TOP PLATE.
2b - INSTALL 2" PIPE GROMMET AS SHOWN.
2c - INSTALL INTAKE COUPLING AS SHOWN.
4
DISCARD
INSTALL BULKHEAD COUPLING USING (2) SCREWS.
INSTALL IN JACKET WITH THE BARBED FITTING
POINTED INTO THE VESTIBULE.
PARTS NEEDED FOR THIS
!
CONVERSION REQUIRE THE
OUTLINED ITEMS FROM THE PARTS BAG
AND CONVERSION KIT RXGY-CK. YOU
MUST HAVE THESE PARTS BEFORE
PROCEEDING.
NOTE:
IF THE IDB
COUPLING IS
REMOVED, IT
MUST BE
REPLACED IN
THE PROPER
ORIENTATION.
AN ARROW IS
PRESENT ON
THE COUPLING
TO INDICATE
THE DIRECTION
OF EXHAUST
FLOW. MAKE
SURE THE
ARROW POINTS
IN THE
CORRECT
DIRECTION.
ST-A1194-29-01
17