4.
Indoor unit observes operation condition of the air conditioner, and displays self diagnosis details on the display panel.
Indoor unit room temperature sensor error
(open or short)
Indoor unit heat exchanger temperature sensor error
(open or short)
Indoor fan motor malfunction
EEPROM error
Option error
(option wasn't set up or option data error)
5.
Operation with abnormal motion
No
Abnormal condition
1
No response from
the remote control
operation signal.
2
Unable to operate the
outdoor unit
Samsung Electronics
Error Mode
• Plug out and plug in 5 seconds
later.
• Press the TURBO button with the
remote control.
• In 3 minutes, check the voltage
between the indoor unit terminal
block N(1) and 1.
OPERATION
Inspection
Able to operate the
remote control.
Unable to operate
the remote control.
AC198V ~ AC242V
No power source
displayed.
LAMP
TIMER
TURBO
: Lamp off
Initial Diagnosis
OK
Press the
(ON/OFF) button in the
indoor unit.
• If it operates, the remote control and
indoor unit receiver are in trouble.
• If not, the indoor unit is in trouble.
Problem with the outdoor unit or PCB
Problem with the relay (RY71) or PCB
Troubleshooting
7-segment
Display
Display
Flickering
: Lamp flickering