Safety Precautions The following safety precautions must be taken when using your air conditioner. • Can cause injury or death. • Disconnect all Risk of electric shock. WARNING remote electric power supplies before servicing, installing or cleaning. • This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard.
View of the Unit The design and shape are subject to change according to the model. Indoor Unit 07/09/12/14 On/Off switch Air filter Air Inlet (under the grille) Air flow blades (outlet) Operation indicator (GREEN) Remote senser Turbo indicator Timer indicator (GREEN) (ORANGE) Indoor Unit...
Page 5
Outdoor Unit US07S2GE SC07AS2X SC07AS2AX SC07ZS2X SC07ZS2AX US09S2GB US09S2GE SC09AS2X SC09ZS2X SC09ZS2AX US12S4GB US12S4GE SC12AS4X SC12ZS4X SC12ZS4AX SH30ZC1(C2)X US14S4GB Air Inlet(Rear) Air Outlet Connection Valve Outdoor Unit US18S0GBA US18S0GEA SC18AS0X SC18ZS0AX US24S6GBA US24S6GEA SC24AS6X SC24ZS6AX Air Inlet(Rear) Air Outlet Connection Valve...
etting Started You have just purchased a split type air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contains valuable information on using your air conditioner. Please take the time to read it as it will help you take full advantage of the unit’s features.
Inserting the Remote Control Batteries You must insert or replace the remote control batteries when : You purchase the air conditioner The remote control does not work correctly Use two AAA, LR03 1.5V batteries. Do not use old batteries or different kinds of batteries together. Batteries may be completely discharged after 12 months, even if they have not actually been used.
Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed. If necessary, press the (On/Off) button.
Cooling Your Room You must select the Cool mode if you wish to adjust the: Cooling temperature Fan speed when cooling If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
Changing the Room Temperature Quickly The Turbo cooling function is used to cool your room as quickly as possible. You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected.
Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
Selecting Energy Saving Mode If you wish to save energy when using your air conditioner, select the Energy saving mode with the Energy saving button. If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner.
Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. To set the operating time, press the button one or more times until the required time is displayed.
Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. To set the operating time, press the button one or more times until the required time is displayed.
Setting the Sleep Timer The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of 6 hours. If you wish to switch the unit off at a specific time, refer to page 17.
Operating Recommendation Here is a recommendation that you should follow when using your air conditioner. Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, the air conditioner starts up again automatically.
Operating Your Air Conditioner Without the Remote Control Your air conditioner can be operated directly from the indoor unit if the remote control is lost or broken. 07/09/12/14 Slide the lower front grille down. 18/24 Open the upper front grille by pulling right and left sides of the grille. Slide the lower front grille down.
Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Problem Explanation/Solution The air conditioner does not Check that the breaker used for the air conditioner is switched on. operate at all Check that the operation indicator on the indoor unit is on;...
Cleaning Your Air Conditioner For the best use of your air conditioner, you must clean it every two weeks regularly to remove the dust that accumulates on the air filter. Before cleaning your air conditioner, ensure that you IMPORTANT have switched off the breaker used for the unit. 07/09/12/14 Slide the lower front grille down.
Cleaning Deodorizing and Bio Filter (Option) To remove minute dust particles and odor, deodorizing and Bio filter are installed in the air conditioner. You should clean the filters every 3 months. 07/09 Open the upper front grille by pulling right and left sides of the grille. Deodorizing Filter Pull out the deodorizing and Bio filter.
Page 24
THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: DIESE KLIMAANLAGE IST FABRIZIERT VON: AYTH H ™Y™KEYH KATA™KEYA™THKE A¶O: ELECTRONICS...