Section 4
WARNING
Unplug unit before servicing or cleaning.
Electric Shock Hazard.
1
Remove the front panel from dispenser. (See
pages 4-1 and 4-2.)
2
Remove paddle wheel pin, agitator, and paddle
wheel. (See pages 4-5 and 4-6.)
3
Unplug the gearmotor wire.
4
Turn the two removal pins toward you as shown
in photo.
Removal of the Gearmotor
Gearmotor
wire
Removal
pins
5
Pull removal pins out to the right.
6
As soon as the second pin is removed, be sure to
hold onto the gearmotor as it slides forward.
Then place the gearmotor aside.
Maintenance