Table of Contents

Advertisement

9.2.9

CAMSET

Siemens AG
<CAMSET MENU>
CAM ID
BAUD RATE
PROTOCOL
DISP MODE
DISP ITEM
TITLE
ALARM TEXT
SAVE
END
CAM ID
Camera ID: 1 – 255
BAUD RATE
Serial communication speed: 2400/4800/9600/19200
PROTOCOL
Operating protocol:
COMMAND: for factory use only
SIEMENS – B
SIEMENS – S
MOLYNX
PELCO – D
PELCO – P
DISP MODE
OSD display mode: Off/Push, On/On
DISP ITEM
Display elements:
1: Camera title and camera number
2: Camera title, zoom factor and camera number
TITLE
Press ENTER to configure camera name
ALARM TEXT
Press ENTER to configure alarm text
SAVE
Press ENTER to save CAMSET configuration
END
Back to the next higher menu level
Move the cursor using the "Far/Near", "Tele/Wide" keys.
Press the MENU key to open a sub-menu.
TITLE TEXT
<TITLE MENU>
A B C D E F G H I J
K L M N O P Q R S T
U V W X Y Z 0 1 2 3
4 5 6 7 8 9
( ) :
; . -
! < > , `
CMD
<
>
S
If you make any changes in the BPS or PROTOCOL submenus, be sure to select SAVE PROTOCOL
& BPS to save your changes.
Do not disconnect the camera from the power source while saving.
(Parity = Even)
(Parity = Even)
(Parity = Even)
(Parity = None)
(Parity = None)
CMD description
← : One position to the left
→ : One position to the right
< : Deletes character at cursor position and
moves to the left
> : Deletes character at cursor position and
moves to the right
S : Save the present setting
E
E : Exit
Camera settings
23