  • Page 1 SERVICE MANUAL DISHWASHER Favorit 80800 Produced by Electrolux Technical Department...
  • Page 2 INTRODUCTION The Favorit 80800 is a free standing, 60cm dishwasher from the Nuremburg Factory in Germany. Features: -AAA energy rating -45db wash noise decibel rating Loading capacity of up to 12 place settings Horizontal cutlery basket on top of the upper basket.
  • Page 3: The Control Panel

    The Control Panel On the left of the control panel are the ON/OFF and Program selection buttons. These buttons are also used to perform certain functions: Adjusting the water softener setting Adding or deleting an audible signal to indicate that a wash program has finished.
  • Page 4: Setting Water Softener

    Setting the Water Softener The dishwasher must be switched off. Press and hold the Auto 65º and the Auto Bio 50º buttons. Press the ON/OFF button. Both the Auto 65º and the Auto Bio 50º will flash and the buttons can be released. Press the Auto Bio 50º...
  • Page 5 Failure of middle spray arm The middle spray arm is monitored by a Hall (magnetic) sensor situated in the inner door panel. This sensor is actioned by a very weak magnet in one end of the middle spray arm. As the magnet at the end of the spray arm passes the Hall sensor a voltage of 4.5 volts is generated which is monitored at the electronic.
  • Page 6 The circulation pump, wash and heating The circulation pump is driven by a single phase asynchronous motor with a 4mF Capacitor connected to the start winding. Different speeds are used during the wash cycle, (depending upon which part of the program is being performed). These speeds are controlled by a Tachometric generator fitted on the end of the motor.
  • Page 7: Turbidity Sensor

    The Turbidity Sensor The machine has 2 automatic programs: Auto 65º and Auto BIO 50º. During these programs a ‘Turbidity sensor’ is used to measure the clarity of the water. This is done by passing a beam of light through the water. The beam of light produces a voltage which is measured and this measurement decides the clarity of the water.
  • Page 8 Fuzzy Detection of the load During the heating step in the main wash two measurements are taken to determine if the machine is washing a full or half load. The first measurement takes place 13 minutes after the start of the heating step and the second measurement is taken 10 minutes later, (23 minutes into heating).
  • Page 9: Program Functions

    Program functions Cycle Fuzzy Turbidity Pre- Main 1st rinse 2nd rinse Final Drying Detection Sensor wash wash rinse Intensive 70º Cold Cold * 40º 70º 70º Normal Cold 65º Cold 70º 65º Auto 65º Cold * * 65º Cold Cold * * 70º...
  • Page 10: Test Program

    Test Program Time / seconds level pump Circulation pump drying function ( ) = possible action variable To reset point Pump out Pump out Calibration of turbidity sensor variable Filling to switch Filling point level variable To reset point Pump out Pump out variable Filling to switch...
  • Page 11: Test Of Individual Components

    Test of individual components With the machine switched off and no wash load. Press and hold the Auto 65º and the Normal 65º buttons. Push the ON/OFF button. The LEDs for the Auto 65º and the Normal 65º programs will flash. Push the Auto 65º...
  • Page 12: Fault Codes

    Fault codes Fault Fault LEDs Audible Display Description Symptom Code Alarm Communication Washing — — When no data can be Program is stopped Error received between input until communications module and main PCB are restored after 10 attempts Water tap Once Pressure switch level is Selected program LED...
  • Page 13 Fault Codes continued Fault Fault LEDs Audible Display Description Symptom Code Alarm Circulation Rinsing 10 times —– Tacho signals are Cycle will stop, water Pump Drying detected but the continues until the circulation pump should pressure switch is not be running made Diverter Rinsing...
  • Page 14 Display and cancellation of fault code memory To display fault codes in the memory: Press and hold Auto 65 and Normal 65 program buttons. Switch the machine on with the ON/OFF button. The LEDs flash for the Auto 65 and the Normal 65 programs. Push the Intensive 70 button.
  • Page 15: Technical Specifications

    Technical Specifications Dimensions: 85cm x 60cm x 60cm Place settings Capacity in tub (water) 4.3 litres Water pressure ( min / max) 1 / 10 Bar Maximum power ———————————————————————————————————————————————— Drain pump: Maximum height 100cm Pumping rate 15 litres / minute Power input 26 watts Winding resistance...
  • Page 16 Technical specifications continued The water softener settings The water hardness shows the hardness before passing through the softener, and the residual water hardness shows the hardness after the water has passed through the softener. The table shown below appears in the customer’s handbook. ºd = German degrees ppm = parts per million * = factory setting...
  • Page 17 Technical Specifications, continued...
  • Page 18: Wiring Diagram

    Wiring Diagram...
  • Page 19: Wiring Plan

    Wiring Plan...
  • Page 20: Legends

    Legends...