Test of individual components
With the machine switched off and no wash load.
Press and hold the Auto 65º and the Normal 65º buttons.
Push the ON/OFF button.
The LEDs for the Auto 65º and the Normal 65º programs will flash.
Push the Auto 65º button.
Each individual componet will operate for 5 seconds in the following order.
1:
Inlet valve
2:
Regeneration valve
3:
Circulation pump
4:
Diverter valve
5:
Drain pump
6:
Turbo drying fan and flap
7:
Detergent dispenser
After 2 minutes the test will automatically terminate.
Alternatively switch the machine off with the ON/OFF button.
Please Note: The heater is not operated during this test