-To disable the AUTO POWER OFF function select "0-OFF"
-To employ the AUTO POWER OFF function select "4-OFF"
c.
Press TARE to save and return to other function
2.4.6 RS-232 Transmission Setting (F5)
a. Refer to the 2.4.1 on how to enter F5
b. Press M+ to select baud rate of 4800, 9600 and 19200
c. Press MODE to enter transmission protocol selection and press M+
to select P=n81 or P=E71
d. Press TARE to save and return to other function
Note: The default value is:
Baud Rate
:9600
DATA BIT
:8
PARITY BIT
:N(NONE)
STOP BIT
:1
CODE
:ASCII
2.4.7 AVERAGE FUNCTION (F6)
a. Refer to the 2.4.1 on how to enter F6
b. Press MODE to select FiLt.0 or FiLt.1
-To disable the AVERAGE FUNCTION select "FiLt.0"
-To employ the AVERAGE FUNCTION select "FiLt.1"
c. Press TARE to save and return to other function
2.4.8 Data Output Setting (F7)
a. Refer to the 2.4.1 on how to enter F7
b. Press MODE to select data output format of SEr.1 or SEr.2
-When selects SEr.1, scale will transmit data continuously via
RS-232 when reading is stable
-When selects SEr.2, data will transmit single data via RS-232
when pressing M+
c. Press TARE to save and return to other function
2.4.9 DATA PRINTOUT FORMAT (F8)
a. Refer to the 2.4.1 on how to enter F8
b. Press MODE to select data output format of Prnt.1 or Prnt.2
-When Prnt.1 is selected, scale will print data in a table format
with number of entries and total weight
-When Prnt.2 is selected, scale will print single data when pressing
M+
c. Press TARE to save and return to other functions