Intelligent W10 Operation Manual

Digital weighing indicator

Advertisement

Quick Links

W10 DIGITAL WEIGHING INDICATOR
OPERATION MANUAL
PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE
THE SCALE
DECEMBER 2001
Specifications subject to change without prior notice

Advertisement

Table of Contents
loading

Summary of Contents for Intelligent W10

  • Page 1 W10 DIGITAL WEIGHING INDICATOR OPERATION MANUAL PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE DECEMBER 2001 Specifications subject to change without prior notice...
  • Page 2: Table Of Contents

    CONTENTS 1. Introduction 2. Cautions 2.1 Warning 2.2 Power Supply 3. Specifications 4. Installation 4.1 Unpack the unit 4.2 Installation Procedures 4.3 Load Cell Connection 5. Operation Panel 5.1 Front Side Illustration 5.2 Back Side Illustration 6. Setting 6.1 Setting Basic Parameters 6.2 Setting Capacity 6.3 Calibration 6.4 Password Setup...
  • Page 3: Introduction

    1. INTRODUCTION The W10 Weighing Indicator utilizes the latest weighing technology available and it’s equipped with free capacity program. What it means, you may now set the desire maximum capacity with the division you like (up to 1/30000). After the parameter setup completes, you will have an indicator that is tailor made just for you to suit your application.
  • Page 4: Cautions

    2. CAUTIONS WARNING Do not attempt any maintenances or troubleshooting other than those mentioned in this manual. To prevent from fire or shock hazard, do not expose the instrument to rain or any types of moisture. To avoid electrical shock, do not disassemble the unit. Please contact your local dealer for more after sale service information.
  • Page 5 SPECIFICATIONS PERFORMANCE Display: 5 digit LCD, 25.4 height Display Resolution: up to 30,000 count, minimum of 0.1 £ g V / div. Count By: 1, 2, 5, 10, 20, 50 Display Speed: 25 times/second Zero Adjustment: -2mV to 20mV Span Adjustment: 0.6mV/V to 4mV/V full scale Zero Drift: <0.3 µ...
  • Page 6: Power Supply

    ¡ Ï ¡ Ð ¡ Ï ¡ Ð Load Cell Connection: 4 Wires ¡ ] E ¡ ^ INTERFACE RS-232C: Baud rate, transmission mode selectable Printer: Centronic type OP-05: External display POWER SUPPLY AC Adaptor: 9V/500mA Rechargeable Battery: 6V, 4Ah...
  • Page 7: Installation

    4.1 UNPACK THE UNIT Unpacking the unit carefully. In the package you shall find: a. This operation manual x 1 b. W10 indicator x 1 c. U shape stand x 1 d. Power adaptor x 1 e. 4 pin load cell connector x 1 Keep the packing material for future transportation purpose.
  • Page 8: Operation Panel

    5. OPERATION PANEL 5.1. FRONT SIDE ILLUSTRATION 1. ZERO Press this key to: (a) reset display value to zero during normal operation when the platform is empty (refer to setting to setup zero range), (b) “+” to be used as increment key during function setup.
  • Page 9 5. M+ Press this key to: (a) accumulate current weight to memory, (b) “SET” to be used for entering setup mode when turn on the indicator. 6. MR Press this key to recall total accumulated weight result stored in memory. Accumulated data will be displayed for about 1.5 second before indicator returns to normal operation status.
  • Page 10 Note: when weight unit selected is “t”, no weight unit symbol will be displayed under normal operation mode. 14. IN-CHARGE INDICATOR Red color: Recharging battery Green color: Charging completed 15. MOTION INDICATOR This indicator indicates weight detected is not stable. When this indication is on, M+ and printer function is disabled.
  • Page 11 5.2 REAR SIDE ILLUSTRATION 1. RS-232C RS232 PIN ASSIGNMENT PIN NUMBER ASSIGNMENT RS232 TXD RS232 RXD 2. PARALLEL INTERFACE PRINTER INTERFACE PIN ASSIGNMENT PIN NUMBER ASSIGNMENT STROBE...
  • Page 12 BUSY 3. ADAPTOR JACK Plug in the adaptor to recharge the indicator for at least 8 hours before use for the first time and apply adaptor when indicator displays low battery signal. 4. LOAD CELL SIGNAL INPUT SIGNAL INPUT PIN ASSIGNMENT PIN NUMBER ASSIGNMENT E = Load cell excitation...
  • Page 13: Setting

    PRINT for move curser right. There are two points shall be fully paid attention to: a. Turn the power on and wait until the indicator displays “W10”, then press M+ to enter setup mode. b. Be sure to press ON/OFF twice when all settings are completed.
  • Page 14 0.0 = NO TRACKING 0.9 = NO TRACKING O.tr. 2.3 = 1.0D PER 1.5 SECONDS (AUTO ZERO TRACKING 2.4 = 1.0D PER 2 SECONDS RANGE) 9.7 = 4.5D PER 3.5 SECONDS 9.8 = 4.5D PER 4.0 SECONDS 9.9 = 4.5D PER 4.5 SECONDS(MAXIMUM) trA? 0 = DISABLE (DEFAULT) (ZERO TRACKING AFTER TARE) 1 = ENABLE...
  • Page 15 SYMBOL/DEFINITION SETTINGS 0.1 = 0.1 DIVISION 0.2 = 0.2 DIVISION 0.3 = 0.3 DIVISION mo.d (MOTION DETECTION DIVISION 2.0 = 2.0 DIVISION (DEFAULT) RANGE) 9.7 = 9.7 DIVISION 9.8 = 9.8 DIVISION 9.9 = 9.9 DIVISION (MAXIMUM) 0.3 = 300 BPS 0.6 = 600 BPS 1.2 = 1200 BPS 2.4 = 2400 BPS...
  • Page 16: Setting Capacity

    6.2 SETTING CAPACITY 2-CAP 6.2.1 Maximum Capacity a. Press M+ for SET when screen display “W10” after turn on the indicator. Press M+ again to enter the parameter setup mode 1-PAr b. Press ZERO for the next selection 2-CAP c. Press M+ to enter Maximum Capacity setup d.
  • Page 17 6.2.3 Decimal Point Position a. Press M+ again to set decimal point location dP. 0. b. Change the figure shown on the display by pressing ZERO and TARE. Press M+ again to return of main menu to continue parameter setup or press ON/OFF twice to start working.
  • Page 18: Calibration

    Use a high quality standard mass. 6.3.1 Zero Calibration 3-CAL cAL.-0 00000 Procedures: a. Press M+ to enter the setup mode when turn on W10. b. Press ZERO or TARE to select and press M+ to enter calibration 3-CAL mode. c. Display will now read .
  • Page 19 indicator is off. d. Press M+ to perform Zero Calibration. e. Display will show “..” before it completes the Zero Calibration. f. Once Zero Calibration is down, it will move to the next step and display will show “00000” for Span Calibration. g.
  • Page 20: Password Setup

    00000 Status DISABLE PASSWORD 0-PAS 00000 a. Press M+ for SET when screen display “W10” after turn on the indicator. Press ZERO or TARE to select and press M+ to 4-Pin enter password setup mode b. Press ZERO, TARE, NET/GROSS and PRINT to set the password.
  • Page 21: Troubleshooting

    7. TROUBLESHOOTING 7.1 ZERO CALIBRATION When the error messages appear on the display, the calibration is invalid. Follow theses guide step by step to solve the problems. A A A A A A A a. Poor connection —To check the connector wirings. b.
  • Page 22 1. Press M+ after completed Zero Calibration, wait till the display reads “00000”. 2. Put the weight on the weighing platform and set the figure of the Span weight on the display by pressing ZERO, TARE, NET/GROSS and PRINT. 3. Press M+ for indicator to execute the command and it will display “.
  • Page 23: Outputs

    8. OUTPUTS A. Specifications: Type: EIA-RS-232C Method: Half-duplex, asynchronous transmission Format: Baud rate: 600, 2400, 4800, 9600 or 19200 Data bit: 7 Parity bit: 1 (EVEN) Stop bit: 1 Code: ASCII Stop bit: 1 Code: ASCII DATA BITS STOP BIT START BIT PARITY BIT B.
  • Page 24 C. Command Mode Timing TARE, ZERO or NTGS READ R x D 300 msec 300msec 350msec 600 baud (Min) (Max) 100msec 2400 baud WEIGHT DATA T x D 1. READ Command. R x D -----(READ) (CR) (LF) e.g. When this READ command is received, a weight data sample immediately following the command will be transmitted.
  • Page 25 FORMAT 1 CR LF HEADER 1 HEADER 2 UNIT WEIGHING RESULT (INCLUDE +,- AND DECIMAL POINT, TOTAL = 8 DIGITS) FORMAT 2 CR LF HEADER 1 HEADER 2 UNIT WEIGHING RESULT (INCLUDE +,- AND DECIMAL POINT, TOTAL = 8 DIGITS) CONTENTS OF HEADER 1 &...
  • Page 26 Units are transmitted as: - Kg, “ “g,” “t and LB (“ “ –space) Terminator” (CR) (LF) D. DB23S CONNECTOR 25 Pin Connector: Function FG RXD TXD * * DSR SG CD DTR * : Connected. 5. OP-05 External Display The display shows the weight data only.
  • Page 27: Care And Maintenance

    9. CARE AND MAINTENANCE a. Do not attempt to disassemble the instrument to clean it. b. Do not submerge the instrument in water, and do not pour or spray water on it directly. c. Never use acetone or other volatile solvents such as thinner, alcohol, etc.

Table of Contents