Section 3
Ice Chute Removal
QC700/QF800
1. Follow steps to remove float reservoir.
2. The ice chute and ice chute grommet will be
removed as a unit. Pull forward on the top of the ice
chute, and slide the ice chute and grommet off the
end of the evaporator spout.
3. Remove evaporator spout insulation.
4. Lift ice chute out of the base.
5. Remove insulation from the bottom of the ice chute.
6. Remove bin level sensor (stainless steel plate) from
ice chute. (Bin level sensor can be disconnected
from the control board for complete removal from
the ice machine.)
NOTE: Clean and sanitize the base and all ice chute
components before reinstalling.
6
3
2
4
5
Part Number 000002688
QF2300
1. Place the toggle switch in the OFF position, turn off
2. Remove ice chute retaining clamp from top of
3. Remove vinyl hose from ice chute spout.
4. Follow steps to remove water reservoir.
5. The ice chute elbow and the ice chute will be
6. Lift ice chute out of the base, tip bottom forward and
7. Remove insulation from ice chute elbow and ice
8. Remove evaporator spout o-ring.
NOTE: Clean and sanitize the base, spout and all ice
chute components before re-installing.
3
SV2011
Ice Machine Operation
the water supply and disconnect electrical power to
the ice machine.
evaporator.
removed separately. Support the ice chute and pull
forward on the elbow to remove.
remove bin level sensor (stainless steel plate) from
the top of the ice chute. (Bin level sensor can be
disconnected from the control board for complete
removal from the ice machine.)
chute base.
4
5
6
2
8
7
SV1787