Ice Machine Operation
Water Level Probe Removal
QF400/QC700/QF800/QF2300
Water Level Probe Removal
1. Place the toggle switch in the OFF position, turn off the
water supply and disconnect electrical power to the ice
machine.
2. Disconnect water supply line at float valve quick disconnect
by depressing stainless steel lever.
3. Pull up on water level probes to remove.
4. Disconnect wires from water level probes or control board.
WATER LEVEL
PROBES
QC700/QF800
WATER LEVEL
PROBES
3-12
WATER LEVEL
PROBES
QF400
QF2300
Water Reservoir Cover Removal
1. Place the toggle switch in the OFF position, turn off
the water supply and disconnect electrical power to
the ice machine.
2. Remove water level probes.
3. Remove water float valve coil.
4. Depress coil and rotate 1/4 turn counterclockwise.
5. With coil wires attached, lift coil off enclosure tube.
6. QF0800/QC0700 ONLY Rotate quarter turn
fasteners counterclockwise.
7. QF0800/QC0700 ONLY Remove cotter key and pin
from ice chute.
8. Remove top cover from float reservoir.
5
SV2043
SV2028
SV1791
4
6
QC700/QF800 Shown
Part Number 000002688
Section 3
3
SV2030