Set Commands; Request Commands - Schäfter+Kirchhoff SK6288GKOC-L Instruction Manual

Color line scan camera 3x 2096 pixels, 14 µm x 14 µm, 60 / 30 mhz pixel frequency
Table of Contents

Advertisement

Set Commands

Set Operation
Description
Goooo<CR>
gain 1 (red) setting 0-24 dB
Boooo<CR>
gain 2 (green) setting 0-24 dB
Hoooo<CR>
gain 3 (blue) setting 0-24 dB
Oppp<CR>
offset 1 (red) setting
Pppp<CR>
offset 2 (green) setting
Qppp<CR>
offset 3 (blue) setting
F8<CR>
output format: 8 bit video data
F12<CR>
output format: 12 bit video data
C30<CR>
camera clock: 30 MHz data rate
C60<CR>
camera clock: 60 MHz data rate
T0<CR>
test pattern off / SCM off
T1<CR>
test pattern on (turns off with power off)
T2<CR>
shading correction on
T3<CR>
auto program Shading Correction / SCM on
T4<CR>
copy flash memory 1 to SCM
T5<CR>
save SCM to flash memory 1
T6<CR>
video out = SCM data
T7<CR>
copy flash memory 2 to SCM
T8<CR>
save SCM to flash memory 2

Request Commands

Request
Return
K<CR>
SK6288GKOC-L returns SK type number
R<CR>
Rev2.23
S<CR>
SNr00163
I<CR>
SK6288GKOC-L
Rev2.23
SNr00163
I1<CR>
VCC: yyyyy
I2<CR>
VDD: yyyyy
I3<CR>
moo: yyyyy
I4<CR>
CLo: yyyyy
I5<CR>
CHi: yyyyy
I6<CR>
Ga1: yyyyy
I7<CR>
Ga2: yyyyy
I8<CR>
Of1: yyyyy
I9<CR>
Of2: yyyyy
I10<CR>
Ga3 yyyyy
I12<CR>
Of3: yyyyy
I19<CR>
Tab: yyyyy
I20<CR>
CLK: yyyyy
Acknowledgement for all set commands:
0 = OK, 1 = not OK
SCM:
Shading Correction Memory
SOS:
Start of Scan
23
Description
returns Revision number
returns Serial number
camera identification
readout
returns VCC (1=10mV)
returns VDD (1=10mV)
returns mode of operation
returns camera clock low fre-
quency (MHz)
returns camera clock high
frequency (MHz)
returns gain 1 (red)
returns gain 2 (green)
returns offset 1 (red)
returns offset 2 (green)
returns gain 3 (blue)
returns offset 3 (blue)
returns video channels
returns selected clock
frequency (MHz)
SK6288GKOC-L Instruction Manual (06.2015)
4 Advanced SkLineScan Software Functions
M0<CR>
line trigger mode0: internal all lines
M1<CR>
line trigger mode1: extern trigger, next
line
M2<CR>
line trigger mode0: internal all lines and set
max line rate
M3<CR>
Pleora Sync Modes
M4<CR>
line trigger mode4: extern trigger and restart
M5<CR>
line trigger mode5: extern SOS, all Lines
Axxxx<CR>
SCM address (xxxx = 0-6287)
Dxxxx<CR>
SCM data (xxxx = 0-4095) and increment
SCM address
Wyyyyy<CR>
line clock frequency (yyyyy = 50-9259) (Hz)
Xyyyyy<CR>
exposure time (yyyyy = 10-20000) (µs)
Vyyyyy<CR>
extern sync divider (yyyyy = 1-32767)
Yppp<CR>
set sync control (ppp = 255)
I21<CR>
ODF: yyyyy
TRM: yyyyy
I22<CR>
I23<CR>
SCO: yyyyy
I24<CR>
Exp: yyyyy
I25<CR>
miX: yyyyy
I26<CR>
LCK: yyyyy
I27<CR>
maZ: yyyyy
I28<CR>
TSc: yyyyy
I29<CR>
SyC: yyyyy
Range of values:
oooo
= 0 ... 1023
ppp
= 0 ... 255
xxxx
= 4 digits integer value as ASCII
yyyyy
= 5 digits integer value as ASCII
returns selected output data
format
returns selected trigger mode
returns shading correction on/
off
returns exposure time or if
DXT=on: exposure time red
(yyyyy = 10-20000) (µs)
returns minimum exposure
time (µs)
returns line frequency (Hz)
returns maximum
line frequency (Hz)
returns Sync Divider
returns Sync Control
© 2015