Table of Contents

Advertisement

Quick Links

Self Powered
User's Manual
Benutzer Handbuch
Important Information,
Wichtige Informationen,
Please Read Before Use!
vor Inbetriebnahme lesen!
KLING
KLING
Junkersstrasse 14
Junkersstrasse 14
D-30179 Hannover
D-30179 Hannover
PHONE 0 (049) 511- 969 97-0
TEL 0 (049) 511- 969 97-0
FAX 0 (049) 511- 67 37 94
FAX 0 (049) 511- 67 37 94
www.kling-freitag.de
www.kling-freitag.de
LINE 212-6 - SP / LINE 212-9 - SP
FREITAG GmbH
&
FREITAG GmbH
&
Version 4.1
Released: 23.03.2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LINE 212-6-SP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KLING & FREITAG LINE 212-6-SP

  • Page 1 Self Powered LINE 212-6 - SP / LINE 212-9 - SP Version 4.1 Benutzer Handbuch User's Manual Released: 23.03.2006 Important Information, Wichtige Informationen, Please Read Before Use! vor Inbetriebnahme lesen! KLING FREITAG GmbH & KLING FREITAG GmbH & Junkersstrasse 14 Junkersstrasse 14 D-30179 Hannover D-30179 Hannover...
  • Page 2 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP KLING & FREITAG GMBH ©2003 - 2006 Version 4.1, 19.06.2006 Page 2 of 45...
  • Page 3 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP Thank you for your decision to buy a Kling & Freitag sound system. To guarantee a trouble-free operating of the equipment and to allow the KLING & FREITAG -- - ‘SP’ speaker system to achieve its full potential please read the operating instructions care- fully before use.
  • Page 4: Table Of Contents

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP Contents Chapter Page General Safety Instructions Introduction SP Loudspeakers Connectors, Controls und Displays Power Cord Rigging Instructions for Line 212 Systems Vertical Suspension Horizontal Suspension Using the ‘allsafe JUNGFALK’ Flying Points Using the Rear Mounted ‘allsafe JUNGFALK’...
  • Page 5: General Safety Instructions

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 1. General Safety Instructions CAUTION Risk of electric shock! Do not open the units! Warning: To avoid electric shock hazard, do not expose this appliance to rain or moisture. The enclosures may only be opened by qualified personnel! Do not install devices in any of the following places: −...
  • Page 6: Mounting The Speakers

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP Maintenance and technical service The user should not perform any maintenance work on the equipment other than that which is described in this manual. Repairs should be executed by a qualified service technician only.
  • Page 7: Introduction Sp Loudspeakers

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 2. Introduction SP Loudspeakers ‘SP’ denotes ‘Self Powered’ series in the K&F range of loudspeakers. Based on selected K&F speaker systems, the ‘SP’ models are equipped with state-of-the-art integrated driver circuits and Class D power amplifier technology.
  • Page 8 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP Modes of Operation − Operations without external controller: with activated filters (FILTERS ‘ON’), all K&F models in the ‘SP Series’ are combin- able with one another by simply linking the signal from one speaker to the next. −...
  • Page 9: Connectors, Controls Und Displays

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 3. Connectors, Controls und Displays 1) LINE IN and LINE OUT (+6 dB) Electronically balanced input and output connectors. Use the XLR female connector (marked ‘IN’) as input. The parallel-wired XLR male connector (‘OUT’) is for connec- tion to further ‘SP’...
  • Page 10 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 4) GAIN CONTROL (± 6 dB) a) The gain control can be used to adjust the input level of the amplifier module by ± 6dB. It serves to balance the volume levels of the various systems. In or- der to avoid overloading the input circuit or mixer’s output circuit, it should normally be set in the case of K&F full-range systems at 0 dB (centre notch setting).
  • Page 11 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 5) FILTERS ON / OFF (High Pass / Low Pass / Equalizer) This switch turns the filter in the SP module on (‘ON’), or off (‘OFF’). a) The switch should always be in the ‘ON’ position when the speakers are being driven without C2 Controller.
  • Page 12 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP The LED stays permanently red, if… …the protection circuitry of the integrated power amplifier cuts in and as a result, no further signal reaches the speaker (Protect Mode). The protection circuitry switches off the integrated power amplifier,… −...
  • Page 13: Power Cord

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 4. Power Cord In Germany, a pre-constructed ready for use power cord is included in the delivery. For deliveries to foreign countries, a pre-constructed power cord incl. PowerCon plug is included.
  • Page 14: Rigging Instructions For Line 212 Systems

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 5. Rigging Instructions for Line 212 Systems The speakers may only be mounted by trained specialised per r r r sonnel with proof The speakers may only be mounted by trained specialised pe sonnel with proof The speakers may only be mounted by trained specialised pe The speakers may only be mounted by trained specialised pe...
  • Page 15: Horizontal Suspension

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 5.2 Horizontal Suspension If a speaker unit consisting of several connected systems is to be flown and aligned, then the individual speakers must be attached to one another before connecting them to the ‘allsafe JUNGFALK’ Flying Track.
  • Page 16: Using The 'Allsafe Jungfalk' Flying Points

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 6. Using the ‘allsafe JUNGFALK’ Flying Points Single Stud Fitting ‘allsafe JUNGFALK’ Flying Point Used as fastener to the ‘allsafe Receptacle for special fasteners. JUNGFALK’ Flying Point. Take the single stud fitting in one ...
  • Page 17: Using The Rear Mounted 'Allsafe Jungfalk' Flying Track

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 7. Using the Rear Mounted ‘allsafe JUNGFALK’ Flying Track The ‘allsafe JUNGFALK’ flying track can be used for fixing and adjust- ing the speaker systems. The ‘allsafe JUNGFALK’ flying track can only support weights up to 73 kg! Please also consult the provided instructions for speakers and Warning...
  • Page 18: Mounting The Double Stud Fitting

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 7.2 Mounting the Double Stud Fitting Double Stud Fitting ‘allsafe JUNGFALK’ Flying Track Used as fastener to the ‘allsafe Receptacle for the double stud fit- JUNGFALK’ Flying Point and the ting.
  • Page 19: Coverage Pattern Of The Line 212

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 8. Coverage Pattern of the Line 212 -- - SP Systems The Line 212 can be operated in a vertical or horizontal position. The coverage pattern of the speaker can be adapted to special needs by a 90° rotatable horn. The following graphics demonstrate how to recognize how the built-in horn emits in a standing speaker: To determine the coverage pattern of the high frequency horn, shine a flashlight through the front covering at the level of the horn.
  • Page 20: Mounting Instructions For Speakers

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 9. Mounting Instructions for Speakers Mount the speakers securely. To avoid injury or damage, always be sure to mount the speakers securely so that they do not fall. Speakers, which are stacked, must be secured with securing straps.
  • Page 21: Arrayed Speaker Systems (Cluster)

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 9.2 Arrayed Speaker Systems (Cluster) If the loudspeakers are operated through the optional K&F C2 System Controller, we recommend turning on the 'Top Low Cut' switch for clustered operation. Thus the fre- quency response for this application can be optimised (see also K&F C2 User's Manual).
  • Page 22: Line 212 Systems On Top Of Sw 215E

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 9.3 LINE 212 Systems on Top of SW 215E In addition to the stacking foot grooves for stacking the same enclosures, the subwoofer SW 215E also has stacking foot grooves for the Line 212 System. One Line 212 System can be quickly and safely posi- tioned on top of a vertically placed SW 215E.
  • Page 23: Wiring

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 10. Wiring Before connecting your SP system, be sure to switch off all connected appliances and turn down all level controls. − We recommend the use of high-quality cables provided by KLING & FREITAG. −...
  • Page 24: Connecting The Power Connectors To The Connecting Terminal

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 10.2 Connecting the Power Connectors to the Connecting Terminal Only use the supplied power cable and connect it to a mains outlet with a 16 A fuse. Warning See instructions in chapter 4‚ ‘Power Cord’ on page 13. KLING &...
  • Page 25: Configurations And Connecting Diagrams

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 11. Configurations and Connecting Diagrams 11.1 Operating the Systems without C2 Controller The full-range system can be used alone or in conjunction with an SP subwoofer. The subwoofer has an integrated filter for use in this mode, which limits the bandwidth. The full-range system is protected against low frequency (subsonic) signals by a high- pass filter and when used with bass speakers it is phase aligned with the subwoofers by means of alignment filters.
  • Page 26: Full Range Mode With Subwoofer

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 11.1.2 Full Range Mode with Subwoofer You can link the input signal (for example from the mixer) from one loudspeaker to another. It makes no difference whether the input signal reaches the bass speaker first and is then transmitted to the mid-high speaker or the other way around.
  • Page 27: Operating The Systems With C2 Controller

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 11.2 Operating the Systems with C2 Controller The frequency responses of SP speakers with switched off filters (FILTERS ‘OFF’) are compatible with those of the corresponding K&F speakers without SP modules (version without XO for subwoofers).
  • Page 28: 2-Way Active Mode With K&F Controller C2

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 11.2.2 2-Way Active Mode with K&F Controller C2 The switch ‘FILTERS’ on The switch ‘FILTERS’ on The switch ‘FILTERS’ on The switch ‘FILTERS’ on the SP speaker must be at the SP speaker must be at the SP speaker must be at the SP speaker must be at...
  • Page 29: Maximum Configuration

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 11.3 Maximum Configuration It is possible to use a large number of SP speakers in parallel simultaneously, however, this number is limited according to the permitted minimum load impedance of the sig- nal source (e.g.
  • Page 30: Operating The Speakers

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 12. Operating the Speakers − Switch off all equipment and make sure that the SP speakers are not connected to a power source. − Connect your SP systems in accordance with the preceding connection diagrams. Use only mains cables, which comply with your national safety regulations.
  • Page 31: Block Diagram Line 212 - Sp

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 14. Block Diagram LINE 212 - SP KLING & FREITAG GMBH ©2003 - 2006 Version 4.1, 19.06.2006 Page 31 of 45...
  • Page 32: Technical Specifications

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 15. Technical Specifications 15.1 LINE 212-6 - SP Loudspeaker Loudspeaker Loudspeaker Loudspeaker Design 2+1-way full-range system with integrated driver and power amplifier technology, completely horn loaded, bass reflex tuning Frequency range -10 dB 51 Hz - 20 kHz ('FILTERS ON'), 65 Hz - 20 kHz ('FILTERS OFF') 49 Hz - 20 kHz ('FILTERS OFF' with C2 Controller)
  • Page 33 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 15.2 LINE 212-9 - SP Loudspeaker Loudspeaker Loudspeaker Loudspeaker Design 2+1-way full-range system with integrated driver and power amplifier technology, completely horn loaded, bass reflex tuning Frequency range -10 dB 51 Hz - 20 kHz ('FILTERS ON'), 65 Hz - 20 kHz ('FILTERS OFF') 49 Hz - 20 kHz ('FILTERS OFF' with C2 Controller) Frequency range ±...
  • Page 34: Measuring Charts

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 16. Measuring Charts 16.1 LINE 212-6 - SP Frequency response ‘on axis’ Filters 'OFF' Filters 'ON' 1000 10000 20000 Frequency (Hz) Beamwidth Horizontal Vertical 1000 10000 20000 Frequency (Hz) Q-Index 1000 10000 20000...
  • Page 35 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP Horizontal coverage pattern 180° 150° 120° 90° Attenuation in dB 60° 30° -3-0 0° -6--3 -30° -9--6 -60° -12--9 -90° -15--12 -120° -18--15 -150° - --18 -180° f [Hz] Vertical coverage pattern 180°...
  • Page 36 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 16.2 LINE 212-9 - SP Frequency response 'on axis' Filters 'OFF' Filters 'ON' 1000 10000 20000 Frequency (Hz) Beamwidth Horizontal Vertical 1000 10000 20000 Frequency (Hz) Q-Index 1000 10000 20000 Frequency (Hz) KLING &...
  • Page 37 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP Horizontal coverage pattern 180° 150° 120° 90° Attenuation in dB 60° 30° -3-0 0° -6--3 -30° -9--6 -60° -12--9 -90° -15--12 -120° -18--15 -150° -21--18 -180° f [Hz] Vertical coverage pattern 180°...
  • Page 38: Dimensions

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 17. Dimensions Flugpunkte ANCRA Jungfalk 120030-31 Kunststoff- füße Flugschiene ANCRA Jungfalk 71202 429 mm 510 mm 214.6 mm [16.890"] [20.079"] [8.450"] Stapel- mulden 15° 81.6 mm [3.211"] 265.9 mm [10.467"] KLING &...
  • Page 39: Accessories For The Line 212 System

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 18. Accessories for the LINE 212 System Click & Fly ® Connector 30° Connector 38.5° Connector 45° Quick Release Pin Application examples Click & Fly ® LINE 212 Single Stud Fitting Double Stud Fitting Rigging chain, adjustable (left / right) Transport cover with castors KLING &...
  • Page 40: Regulations For Disposal

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 19. Regulations for Disposal 19.1 Germany: It is not allowed to dispose of used electrical equipment as domestic waste. But please do not dispose of them at official collecting points for recycling either! All Kling &...
  • Page 41: Declaration Of Conformity And International Certificates

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 20. Declaration of Conformity and International Certificates 20.1 Declaration of Conformity DECLARATION OF CONFORMITY EMC-Directive: 89 / 336 / EEC Low Voltage Directive: 73 / 23 / EEC KLING & FREITAG GMBH Junkersstrasse 14 30179 Hannover Germany...
  • Page 42: Emv Certificate Directive 89 / 336 / Ewg

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 20.2 EMV Certificate Directive 89 / 336 / EWG KLING & FREITAG GMBH ©2003 - 2006 Version 4.1, 19.06.2006 Page 42 of 45...
  • Page 43 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP KLING & FREITAG GMBH ©2003 - 2006 Version 4.1, 19.06.2006 Page 43 of 45...
  • Page 44: Tüv Certificate For The Usa And Canada (Ul 6500)

    User’s Manual LINE 212-6 - SP / LINE 212-9 - SP 20.3 TÜV Certificate for the USA and Canada (UL 6500) KLING & FREITAG GMBH ©2003 - 2006 Version 4.1, 19.06.2006 Page 44 of 45...
  • Page 45 User’s Manual LINE 212-6 - SP / LINE 212-9 - SP KLING & FREITAG GMBH ©2003 - 2006 Version 4.1, 19.06.2006 Page 45 of 45...

This manual is also suitable for:

Line 212-9-sp

Table of Contents