Download Print this page

Frigidaire FGF356MXAWD Instructions page 2

Advertisement

How to Convert the Range for use with LP/
Propane Gas
1. Convert the Pressure
Regulator
To access
the gas regulator,
remove
the storage
drawer
or warmer
drawer. If equipped with a storage drawer, open and remove the drawer
completely.
For models equipped with a storage
drawer or front panel,
remove the storage or front panel and skip steps a & b below. For models
equipped with warmer drawer, follow all the instructions
below to remove
the warmer
drawer.
a.
_!_
Electrical
Shock Hazard can occur and result in
serious
injury or death.
Disconnect
electrical
power to the range
before removing
the warmer
drawer for servicing.
b.
Locate glide lever on each side of drawer, pull up on the left glide lever
and push down on the right glide lever (See Figure 1).
c.
Pull the drawer away from the range (See Figure 2).
d.
Remove the regulator access cover if equipped.
Do not remove
the
Pressure
Regulator
or allow
it to turn.
e.
Remove
the dust protector
from the cap.
Using a 5/8" wrench,
unscrew the cap from the pressure
regulator.
Do not remove
the
spring
from the regulator.
f.
Turn the cap over so the hollow end faces outward. Place the solid
end of the cap into the loop end of the dust protector (See Figure 3).
g.
Replace the cap on the regulator. The letters LP should be visible on
the exposed
end of the cap. Snap the dust protector
over
the
regulator
cap.
Pull up with finger
Left Glide
Pressure
Front access to Regulator:
Regulator
Open storage
or warmer
drawer,
located at
or remove
lower panel
rear of
(on some models)
FIGURE
2
FIGURE
3
Spring
Dust
Protector
Hollow
End
Solid End
Towards
Towards
Regulator
Regulator
for Natural
Gas
for LP/Propane
Gas
Push down with finger
FIGURE
1
Natural Gas Orifice to LP Orifice Conversion
for each type of burner
5,000
BTU Natural
Gas
converts
to 4,500
BTU LP Gas
Install (blue)orifice 68mm for LP
9,500 BTU NaturalGas
converts to 8,000 BTU LP Gas
Install orifice (no coIor) ,89mmfor LP
14,000 BTU Natural Gas
12,000 BTU Natural Gas
converts to 11,000 BTU LP Gas
converts to 10,000 BTU LP Gas
Install (red) orifice !.01mm for LP
Install (green) orifice .95mm for LP
FIGURE
4

Advertisement

loading

This manual is also suitable for:

Fgf326asgFgfb68cbbFgfb68csbFgfb68cqbFgf366asbFgf355asb ... Show all