INSTALLATION A ND
SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
This conversion
kit must be installed by a qualified service technician
in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction.
Failure
to follow instructions may result in fire, explosion or production of carbon monoxide causing property damage,
personal injury or loss of life. The qualified service agency is responsible for the proper installation ofthis kit. The
installation is not proper and complete until the operation ofthe converted appliance is checked as specified in the
manufacturer's
instructions supplied with this kit.
Before proceeding with the conversion, shut offthe gas supply before disconnecting electrical power
to the range. Be sure both power supplies are off before installing the conversion kit. Failure to do so could cause
serious bodily injury.
Determine the combination of top burners that are featured on your range. Then identify the parts you need from
this kit to complete the LP. conversion. When burners are converted from Natural to LP the BTU rating is as follows:
5,000 BTU* Natural gas to 4,500 BTU* LP Gas
9,500 BTU* Natural Gas to 8,000 BTU* LP Gas
12,000 BTU* Natural Gas to 10,000 BTU* LP Gas
14,000 BTU* Natural Gas to 11,000 BTU* LP Gas
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
Part Number
316037526
316248105
316005215
316005216
316005217
316005218
316005219
316005220
316005221
316005222
316241200
316237904
316237905
316237906
316237907
Part Description
L.P. Conversion Kit Label
Instructions for converting range to LP Gas
Rating Plate - English
Rating Plate - English
Rating Plate - English
Rating Plate - English
Rating Plate - French
Rating Plate - French
Rating Plate - French
Rating Plate - French
L.P. Conversion Label
Orifice - 11,000 BTU*
Orifice- 10,000 BTU*
Orifice - 8,000 BTU*
Orifice - 4,500 BTU*
Notes
English and French
English, French and Spanish
4 - 8K
3+1
2+1+1
1+1+1+1
4 - 8K
3+1
2+1+1
1+1+1+1
English, French and Spanish
RED
GREEN
NO COLOR
BLUE
*Note: For operation at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each 1000
ft. above sea level.
IM PORTANT: After replacing the natural gas to LP orifices; be sure to keep the original factory installed natural gas
orifices for future range conversion back to natura! gas. The factory orifices are marked with 101 for 5,000 BTU; 154
for 9,500 BTU; 175 for 12,000 BTU and 193 for 14,000 BTU.
Tools Required for L.P. Conversion:
3/8", 1/2" and 5/8" Open End Wrench
1/8" Wide Flat Blade Screwdriver
7mm Nutdriver