  • Page 1 DelfiScan C85 General Purpose Corded Handheld Area Imager Bar Code Reader Quick Reference Guide...
  • Page 2 Delfi website (www.delfi.com) or provided on appropriate media. Disclaimer Delfi has taken reasonable measures to provide information in this manual that is complete and accurate, however, Delfi reserves the right to change any specification at any time without prior notice. Patents...
  • Page 3: Table Of Contents

    Customers Under Software Support ........ vi Description ..................1 Setting Up the Reader ..............2 Connect/Disconnect Cable to Reader ....... 2 Using the DelfiScan C85 ............... 3 Selecting the Interface Type ............4 Interface Selection .............. 4 Configuring the Interface .......... 5 Keyboard Interface ............
  • Page 4 NOTES DelfiScan C85...
  • Page 5: End User Software License Agreement (Eula)

    End User, whether obtained directly or indirectly from Delfi. 1.5 "Software" means any software or computer programs of Delfi or its third party licensors in machine readable form which is embedded in the Delfi Product, whether obtained directly or indirectly from Delfi, including any replacement, update, upgrade, enhancement or modification.
  • Page 6 Delfi or Delfi' s third party licensors and that the Software is protected by intellectual property laws and treaties. The license set forth in this Agreement does not transfer to End User any ownership of Delfi' s or its third party licensors' copyrights, patents, trademarks, service marks, trade secrets, or other intel- lectual property rights and End User shall have no right to commence any legal actions to obtain such rights.
  • Page 7 Delfi controls the defense or settlement of the claim, and 3) End User cooperates fully with Delfi in such defense or settlement. All notices of a claim should be sent to Delfi Technologies A/S, Galoche Alle 1, 4600 Køge, Denmark.
  • Page 8: Software Product Policy

    Notices to Delfi shall be sent to the attention of Contract Administration, Delfi Technologies A/S, Galoche Alle 1, 4600 Køge, Denmark., or such other address as may be specified by Delfi in writing.
  • Page 9: Description

    DelfiScan C85 Description The DelfiScan C85 2D imager has been specifically created to meet the market demand for omni-directional reading performance on virtually all codes at an affordable price. Ele- gant design details are incorporated into a smaller, balanced lightweight enclosure without sacrificing Delfi's wellknown durability.
  • Page 10: Setting Up The Reader

    Rear View Host Connection — The QuickScan plugs directly into the host device as shown in Figure 2. The power can also be supplied through an external power supply via the Interface Cable sup-plied with a power jack. DelfiScan C85...
  • Page 11: Using The Delfiscan C85

    Side View Using the DelfiScan C85 The DelfiScan C85 normally functions by capturing and decoding codes. The aiming system is activated on trigger pull and indicates the center of the field of view which should be positioned over the bar code:...
  • Page 12: Selecting The Interface Type

    Suc-cessful reading is signaled by an audible tone plus a good-read green spot LED indicator. Reference the DelfiScan C85 Product Reference Guide (PRG) on the Delfi website for more information about this feature and other programmable settings. Selecting the Interface Type...
  • Page 13: Configuring The Interface

    Selecting the Interface Type Configuring the Interface Scan the appropriate programming bar code to select the interface type for your system. Unlike some other programming features and options, interface selections require that you scan only one programming bar code label. DO NOT scan an ENTER/EXIT bar code prior to scan- ning an interface selection bar code.
  • Page 14: Keyboard Interface

    USB Com to simulate RS-232 standard interface Select USB-COM-STD USB-OEM USB-OEM (can be used for OPOS/UPOS/JavaPOS) Select USB-OEM a .Download the correct USB Com driver from www.delfi.com Keyboard Interface Use the programming bar codes to select options for USB Keyboard and Wedge Interfaces. KEYBOARD AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 &...
  • Page 15 Selecting the Interface Type KEYBOARD (continued) AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key Select KBD-AT-ALT Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard Select KBD-AT-ALT-NK PC/XT w/Standard Key Encoding Select KBD-XT Keyboard Wedge for IBM Terminal 3153 Select KBD-IBM-3153...
  • Page 16 KEYBOARD (continued) USB Keyboard with alternate key encoding Select USB Alternate Keyboard USB Keyboard for Apple computers Select USB-KBD-APPLE Keyboard Wedge for DIGITAL Terminals VT2xx, VT3xx, VT4xx Select KBD-DIG-VT USB Keyboard with standard key encoding Select USB Keyboard DelfiScan C85...
  • Page 17: Scancode Tables

    Selecting the Interface Type Scancode Tables Reference the DelfiScan C85 PRG for information about control character emulation for keyboard interfaces. Country Mode This feature specifies the country/language supported by the keyboard. Only these interfaces support ALL Country Modes: • USB Keyboard (without alternate key encoding) •...
  • Page 18 Country Mode = Croatia* Country Mode = Czech Republic* Country Mode = Denmark* Country Mode = France $CKBCO13(CR) Country Mode = French Canadian* Country Mode = Germany *Supports only the interfaces listed in the Country Mode feature description DelfiScan C85...
  • Page 19 Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Hungary* Country Mode = Italy Country Mode = Japanese 106-key* Country Mode = Lithuanian* Country Mode = Norway* Country Mode = Poland* *Supports only the interfaces listed in the Country Mode feature description Quick Reference Guide...
  • Page 20 COUNTRY MODE (continued) Country Mode = Portugal* Country Mode = Romania* Country Mode = Spain Country Mode = Sweden Country Mode = Slovakia* Country Mode = Switzerland* *Supports only the interfaces listed in the Country Mode feature description DelfiScan C85...
  • Page 21: Caps Lock State

    Selecting the Interface Type Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected. CAPS LOCK STATE ENTER/EXIT PROGRAMMING MODE Caps Lock State = Caps Lock OFF Caps Lock State = Caps Lock ON...
  • Page 22: Numlock

    This option specifies the setting of the Numbers Lock (Num- lock) key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard. NUMLOCK ENTER/EXIT PROGRAMMING MODE Numlock = Numlock key unchanged Numlock = Numlock key toggled DelfiScan C85...
  • Page 23: Programming

    Interfaces section, select other options and customize your reader through use of the programming bar codes available in the DelfiScan C85 PRG. Check the corresponding features section for your interface, and also the Data Editing and Symbologies chapters of the PRG.
  • Page 24: Reading Parameters

    Move the reader toward the target and center the aiming pat-tern and illumination system to capture and decode the image. See Using the DelfiScan C85 on page 3 for more information. The aiming system will briefly switch off after the acquisition time, and if no code is decoded will switch on again before the next acquisition.
  • Page 25: Operating Modes

    Operating Modes Operating Modes Scan Mode The imager can be set to operate in one of several scanning modes. See the PRG for more information and settings for any of the options: Trigger Single (Default) — This mode is associated with typical handheld reader operation.
  • Page 26 Operating Modes SCAN MODE ♦ Scan Mode = Trigger Single Scan Mode = Trigger Pulse Multiple Scan Mode = Flashing Scan Mode = Trigger Hold Multiple Scan Mode = Scan Mode = Always On Object Detection DelfiScan C85...
  • Page 27: Pick Mode

    Operating Modes Pick Mode Specifies the ability of the reader to decode labels only when they are close to the center of the aiming pattern, which is the area indicated by the two blue arrows. Pick Mode is a Decod-ing and Transmission process where bar codes that are not within the configurable distance from the center of the aiming pattern are not acknowledged or transmitted to the host.
  • Page 28: Technical Specifications

    Operating (typical): 140mA Voltage & Current Operating (max): 380mA Idle/standby (typical): 50mA Performance Characteristics Light Source LEDs Roll (Tilt) Tolerance Up to ± 360° Pitch Tolerance ± 65° Skew (Yaw) Tolerance ± 60° Print Contrast Minimum 25% minimum reflectance DelfiScan C85...
  • Page 29 Technical Specifications Depth of Field (Typical) Symbology 5mil: 0.2" - 5.9" (0.5 - 15cm) 10mil: 0" - 8.7" (0 - 22cm) Code 39 20mil: up to 16" (40cm) 7.5mil: 0" - 5.9" (0 - 15cm) 13mil: 0.2" - 13.8" (0.5 - 35cm) 6.6mil: 0.39"...
  • Page 30 GS1 DataBar Expanded; GS1 DataBar Truncated; DATABAR Expanded Coupon. 2D / Stacked Codes The DelfiScan C85 scanner is capable of decoding the following sybmologies using mul- tiple frames (i.e. Multi-Frame Decoding): Datamatrix; Inverse Datamatrix; Datamatrix is configurable for the following parameters:;...
  • Page 31: Led And Beeper Indications

    LED and Beeper Indications Contaminants Spray/rain IEC 529-IP42 Dust/particulates (IP51 QD2430-E model only) ESD Level 16 KV Regulatory Electrical Safety UL 60950, CSA C22.2 No. 60950, IEC 60950 North America (FCC) : Part 15 Class B; Canada ( IC) : ICES- 003 Class B;...
  • Page 32 Green Spot flashes momentarily spot on for the time specified by the config- ured value. Except when in sleep mode or when a Good Read LED Duration other than 00 is selected DelfiScan C85...
  • Page 33: Programming Mode

    LED and Beeper Indications Programming Mode - The following indications ONLY occur when the reader is in Programming Mode. INDICATION DESCRIPTION BEEPER Label Programming A valid programming label LED blinks contin- Reader sounds four Mode Entry has been scanned. uously low frequency beeps.
  • Page 34: Error Codes

    FRU indication code. The following table describes the LED flashes/beep codes associated with an error found. Number of LED Error Corrective Action Flashes/ Beeps Configuration Interface PCB Contact Helpdesk for assis- tance Digital PCB Imager DelfiScan C85...
  • Page 35: Cleaning

    Cleaning Cleaning Exterior surfaces and scan windows exposed to spills, smudges or debris require periodic cleaning to ensure best performance during scanning. Use a soft, dry cloth to clean the product. If the product is very soiled, clean it with a soft cloth moistened with a diluted non-aggressive cleaning solution or diluted ethyl alcohol.
  • Page 36: Regulatory Information

    Any changes or modifications to equipment, not expressly approved by Delfi could void the user's authority to operate the equipment. Statement of Agency Compliance This device complies with part 15 of the FCC Rules. Operation...
  • Page 37: Canadian Notice

    Regulatory Information Canadian Notice This equipment does not exceed the Class B limits for radio noise emissions as described in the Radio Interference Regu- lations of the Canadian Department of Communications. Le present appareil numerique n’emet pas de bruits radio- electriques depassant les limites applicables aux appareils numeriques de la classe B prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Commu-...
  • Page 38: Imager Labeling

    Please view the labels on your product for actual details, as they may vary from those depicted. Scanner Regulatory The DelfiScan Handheld Reader is not user- serviceable. Opening the case of the unit can cause internal damage and will void the war- ranty. CAUTION DelfiScan C85...
  • Page 39: Weee Statement

    Spanish Si desea información acerca de los procedimientos para el desecho de los residuos del equipo eléctrico y electrónico (WEEE), visite la página Web www.delfi.com. Portuguese Para informações sobre a disposição de Sucatagem de Equipamentos Elétricos e Eletrônicos (WEEE -Waste Electrical and Electronic Equipment), consultar o site web www.delfi.com.
  • Page 40: Delfi Technologies

    90 day period starting from the date of shipment of the repaired product from Delfi or until the expiration of the original warranty period, whichever is longer.
  • Page 41: Limited Factory Warranty

    Risk of Loss Customer shall bear risk of loss or damage for product in transit to Delfi. Delfi shall assume risk of loss or damage for product in Delfi’s possession. In the absence of specific written instructions for the return of product to Customer, Delfi will select the carrier, but Delfi shall not thereby assume any liability in connection with the return shipment.
  • Page 42: Ergonomic Recommendations

    Keep objects that are used frequently within easy reach • Perform tasks at correct heights • Reduce or eliminate vibration • Reduce or eliminate direct pressure • Provide adjustable workstations • Provide adequate clearance • Provide a suitable working environment • Improve work procedures. DelfiScan C85...
  • Page 43: Services And Support

    Services and Support Services and Support Delfi provides several services as well as technical support through its website. Please check our website at www.delfi.com/en for further information. Quick Reference Guide...
  • Page 44 Services and Support NOTES DelfiScan C85...
  • Page 45 Services and Support NOTES Quick Reference Guide...
  • Page 46 Sweden Norway Denmark Solkraftsvägen 25 Rugdetrekket 2 Galoche Alle 1 135 70 Stockholm 3370 Vikersund 4600 Køge Tel. +46 8 742 20 55 Tel. +47 32 78 12 11 Tel. +45 70 222 555 www.delfi.com info@delfi.com (Rev 0.9.0.5)