Revision History Rev. No. Released Date Description Rev.B Beta Apr. 16, 2009 First Release Page 22 Code 128/EAN-128 Setting – Modify ISBT Concatenation Off option code to “4” Rev.B May 05, 2009 and ISBT Concatenation On option code to “5”. Page 25 GS1 Databar Setting –...
Page 3
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written per-mission of Delfi Technologies A/S. Owners of Delfi products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes.
Table of Contents Getting Started Getting Familiar with Your DelfiScan Connecting to Your Host Using Accessaries Configure Your DelfiScan Bar Code Programming Manual Programming Procedures Host Interface Selection Symbology Reading Control Keyboard Interface Control Serial Interface Control Wand/Laser Emulation Control Operation Control Condensed DataWizard Appendix...
If you would like to remove the cable, please provided by the DelfiScan Programming Manual available at straighten one end of a paper clip, then insert it into the cable www.delfi.com release hole to pull out the cable. C71 Series...
Getting Started Using Accessories You can enhance productivity of your workforce by using various accessories to fulfill a wide variety of application demand. Universal Holder A stylish Universal Holder is designed for storing your imager when not in use. It serves protect imager...
Configure Your DelfiScan Bar Code Programming Menu Family Code The Family Code is scanned to select the user desired programming The DelfiScan bar code commands are specially designed Proprietary family. DelfiScan has already provided more than one hundred bar code labels which allow you to set the DelfiScan internal programming families to meet any specific requirements.
Configure Your DelfiScan Programming Procedures As you scan the bar code command to select the desired parameters, If the programming family must take multiple scans selection, cycling information about the final selected parameters represented by the scan selection, or dual level selection procedures, the family of the bar code commands are stored in the DelfiScan’s internal Flash programming menu will be marked with the matched representing Memory ASIC or non-volatile memory.
Page 9
Configure Your DelfiScan Program & End System List, Group & Master Default Scan Scan “PROGRAM” “SYSLIST” DelfiScan will list the product information and DelfiScan will enter programming mode, revision number to host via selected host interface, and inhibit all non-programming functions. then issue the completion beeping.
Page 10
Configure Your DelfiScan Single scan selection Multiple scans selection Scan Scan “PROGRAM” Enter programming mode. “PROGRAM” Enter programming mode. Select one of desired Select one of desired Scan Scan programming families. programming families. One of Family Codes One of Family Codes 1.
Page 11
Configure Your DelfiScan Cycling scan selection Dual level selection Scan Scan “PROGRAM” Enter programming mode. “PROGRAM” Enter programming mode. Select one of desired Select one of desired Scan Scan programming families. programming families. One of Family Codes One of Family Codes Cycling select one or Select several option codes (1st) Scan...
Configure Your DelfiScan Host Interface Selection PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code IBM PS/2, 25-30 series keyboard wedge interface Host Interface Selection Standard/TTL RS-232 peer-to-peer serial Wand emulation USB Com Port Emulation PS/2 (DOS/V) direct link (keyboard replacement) PS/2 (DOS/V) keyboard wedge turbo mode PS/2 (DOS/V) keyboard wedge standard mode Laser emulation...
Configure Your DelfiScan Symbology Reading Control User Defined Symbol ID PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Code 128 (default=B) (1 character) Symbol ID : 1 character UCC/EAN-128 (default=C) (1 character) UPC-A (default=A) (1 character) EAN-13 (default=F) (1 character) Codabar/NW-7 (default=D)
Page 14
Configure Your DelfiScan Symbology Reading Control Symbology ID Transmission PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Disable symbology ID transmission Symbology ID Transmission Enable prefix CINO symbology ID transmission Enable suffix CINO symbology ID transmission Enable both prefix and suffix CINO symbology ID transmission Enable prefix AIM symbology ID transmission Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission...
Page 15
Configure Your DelfiScan Symbology Reading Control ♦ Readable Bar Code Setting ♦ PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Auto Readable Symbology Setting Code 128 * UPC-A * UPC-E * EAN-13 * EAN-8 * Codabar/NW-7 * Code 39 * Trioptic Code 39 Standard/Industrial 2 of 5 Matrix 2 of 5...
Page 16
Configure Your DelfiScan Symbology Reading Control Code 39/Code 32 Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Disable Code 39 Code 39 Family Setting Enable Code 39 Select Standard Code 39 as primary format Select Full ASCII Code 39 as primary format Select Code 32 (PARAF, Italian Pharmaceutical) as primary format Disable start/stop symbol transmission Enable start/stop symbol transmission...
Page 17
Configure Your DelfiScan Symbology Reading Control Codabar/NW-7 Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Disable Codabar Codabar Setting Enable Codabar Select Codabar standard format Select Codabar ABC format Select Codabar CLSI format Select Codabar CX format Disable start/stop symbol transmission Enable ABCD/ABCD start/stop symbol transmission Enable abcd/abcd start/stop symbol transmission Enable ABCD/TN*E start/stop symbol transmission...
Page 18
Configure Your DelfiScan Symbology Reading Control UPC-A & UPC-E Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Disable UPC-A UPC Family Setting Enable UPC-A Disable UPC-E Enable UPC-E Disable UPC-E expansion Enable UPC-E expansion Disable UPC standardization Enable UPC standardization Disable UPC numeric system Enable UPC numeric system Disable UPC-A check digit transmission...
Page 19
Configure Your DelfiScan Symbology Reading Control UPC-A & UPC-E Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Select UPC without supplement digits UPC Supplement Setting Select UPC with only 2 supplement digits Select UPC with only 5 supplement digits Select UPC with 2/5 supplement digits Disable force supplement digits output Enable force supplement digits output...
Configure Your DelfiScan Symbology Reading Control Code 25 Family Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Disable Standard/Industrial 2 of 5 Code 25 Setting Enable Standard/Industrial 2 of 5 Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable China Postal Code Enable China Postal Code Disable check digit verification...
Configure Your DelfiScan Symbology Reading Control MSI/Plessey Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Disable MSI/Plessy MSI/Plessey Setting Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission Enable check digit transmission Default (04) MSI/Plessey Min.
Page 26
Configure Your DelfiScan Symbology Reading Control Code 128 & UCC/EAN 128 Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Disable Code 128 and UCC/EAN-128 Code 128/EAN-128 Setting Enable Code 128 and UCC/EAN-128 Disable function code conversion Enable function code conversion ISBT Concatenation Off ISBT Concatenation On Default (01)
Page 27
Configure Your DelfiScan Symbology Reading Control UK/Plessey Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Disable UK/Plessey UK/Plessey Setting Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission Default (04)
Configure Your DelfiScan Keyboard Interface Control Keyboard Layout (Language) Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code USA (QWERTY) Keyboard Layout France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY) Canadian French (QWERTY) Spain (QWERTY) Sweden/Finland (QWERTY) Portugal (QWERTY) Norway (QWERTY) Latin America (QWERTY) Italy (QWERTY)
Page 32
Configure Your DelfiScan Keyboard Interface Control Record Suffix, Preamble, Postamble & Caps Lock PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code None Record Suffix RETURN SPACE ENTER (Numeric Key Pad) User defined character (1 character) 5, (00-7F) None Preamble 1-15 characters [00-7F], [FIN] Maximum 15-character input;...
Page 33
Configure Your DelfiScan Keyboard Interface Control Delay Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code None Intermessage Delay 1-99 (x5) msec. (2 digits) Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. None Intercharacter Delay 1-99 (x5) msec.
Page 34
Configure Your DelfiScan Keyboard Interface Control Emulation Setting & Upper/Lower Case Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Enable ASCII 00-31 code as keyboard function code output Function Key Emulation Ctrl-Output Refer to Appendix – Keyboard Function Code Table for details. Disable key pad emulation Key Pad Emulation Enable numeric output as key pad (Num Lock On) output...
Configure Your DelfiScan Serial Interface Control Record Suffix, Preamble ,Postamble Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Disable STX/ETX transmission STX/ETX Control Enable STX/ETX transmission STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
Page 36
Configure Your DelfiScan Serial Interface Control Delay Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code None Intermessage Delay 1-99 (x5) msec. (2 digits) Scan 2 digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. None Intercharacter Delay 1-99 (x5) msec.
Page 37
Configure Your DelfiScan Serial Interface Control Protocol, Baud Rate, Data Frame & Time Out Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code None (free running mode) Handshaking Protocol RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking) 38.4K BPS 2400 BPS Baud Rate (BPS) 19.2K BPS...
Configure Your DelfiScan Wand/Laser Emulation Control Output Polarity, Signal State, Margin/Module Time, etc. PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code High level (5Vdc) on Bar (low level on Space) Output Polarity Low level (0Vdc) on Bar (high level on Space) Determine the output voltage level for both bar and space.
Configure Your DelfiScan Operation Control Operation Mode Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Low Power mode Force mode Operation Mode Trigger mode/Serial mode Toggle mode Presentation mode Diagnostic mode Alternative mode Level mode Flash mode Presentation mode Presentation Scanning Mode Flash mode Force mode...
Page 40
Configure Your DelfiScan pre-defined auto power off time, the scanner enters the idle state after the pre-defined auto power off duration. Presentation Scanning Mode When the scanner is placed on SmartStand, the scanner’s built-in sensor will switch the scanner from hand-held scanning to presentation scanning automatically.
Page 41
Configure Your DelfiScan Operation Control Buzzer, Indicator, Vibrator, Inverse Reading, Dollar Sign PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Buzzer tone – mute Buzzer Tone Adjust Buzzer tone – low Buzzer tone – medium Buzzer tone – high Buzzer tone - extremely high Power-on beep No power-on beep...
Page 43
Configure Your DelfiScan Operation Control Time-out Setting, Good Read Beep Duration PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code Short Auto Power Off Duration Medium Long Extremely long Short Hands Free Time-out Medium Long Extremely long Short Good Read Duration Medium Long Extremely long...
Page 44
Configure Your DelfiScan Operation Control SmartStand Power Off & Presentation Auto-sense PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code 3 mins SmartStand Power Off 5 mins Timeout 10 mins Only available for DelfiScan Laser model Disable Presentation Scanning Enable Auto-sense The SmartStand Power Off Timeout is a pre-defined duration for scanner placed in SmartStand.
Configure Your DelfiScan Condensed DataWizard Preamble, Postamble, Data Length & Symbol ID Trans. PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code None Preamble 1-15 characters [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. None Postamble 1-15 characters [00-7F], [FIN] Maximum 15-character input;...
Page 46
Configure Your DelfiScan Condensed DataWizard Data Formatter Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Disable Formatter Control Select one bar code symbology (2 digits) automatic termination Select all bar code symbologies automatic termination Disable 1st Insertion Enable (2 digits)
Page 47
Configure Your DelfiScan Condensed DataWizard Data Verifier Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Disable Verifier Control Select one bar code symbology automatic termination (2 digits) Select all bar code symbologies automatic termination Disable Identified Data Length Enable (2 digits)
Page 48
Configure Your DelfiScan Condensed DataWizard Data Replacer Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Disable Replacer Control Select one bar code symbology (2 digits) automatic termination Select all bar code symbologies automatic termination Disable 1st Replacement Enable (2 digits)
Page 49
Configure Your DelfiScan Condensed DataWizard Data Organizer Setting PROGRAM M_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Disable Organizer Control Select one bar code symbology (2 digits) automatic termination Select all bar code symbologies automatic termination Disable 1st Organization Enable (2 digits)
Page 50
Configure Your DelfiScan Select a Bar Code Symbology You can select one or all types of bar code symbologies to use [Data Verifier, Data Replacer, Data Organizer] Condensed DataWizard for advanced transmission arrangement. If there is a 11-character data string, please refer to the If you scan “00”...
Configure Your DelfiScan Programming Procedure [Data Verifier] [Data Replacer] Scan “Program” to enter the programming mode. Scan “Replacer Control” and set bar code symbology to “48”. Scan “Verifier Control” and set bar code symbology to “48” (Interleaved 2 of 5). Scan “1st Replacement”...
Appendix ] = Flag Character Symbology ID Table c = Code Character Each AIM Code Identifier contains the three-character string ]cm where: m = Modifier Character Cino ID AIM ID Cino ID AIM ID Code Code Primary Format Primary Format Code Code Modified...
Appendix Keyboard Function Code Table ANSI ASCII Key Function ANSI ASCII Key Function RESERVED CTRL (Left) ALT (Left) SHIFT CAPS LOCK NUM LOCK INS (Insert) (Edit) DEL (Delete) (Edit) BACK SPACE HOME (Edit) END (Edit) PAGE UP (Edit) PAGE DOWN (Edit) UP (Edit) ENTER (CR) DOWN (Edit)
Appendix HEX/ASCII Reference Table ASCII Input Shortcut To configure the user definable parameters of DelfiScan via programming menu, DelfiScan will ask you to scan your desired SPACE ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details. "...
Appendix Host Interface Quick Set RS232 Serial PS/2 (DOS/V) KBW Standard Mode USB HID Standard Mode Keyboard Replacement PS/2 (DOS/V) KBW Turbo Mode USB HID Turbo Mode USB Com Port Emulation...
Appendix Operation Mode Quick Set Lower Power (Low power trigger) Force (Continued power on) Alternative (Periodic power off) Trigger (External trigger) Toggle (Repeat reading) Flash (Pulse driven reading) Presentation (Auto sensing) Diagnostic (Test reading) Level (Auto power off)
Appendix System Commands PROGRAM System Information List (Enter Programming Mode) (SYSLIST) Save User Default FIN (Finish) Factory Default (M_DEFAULT) User Default PowerTool Host Link (Exit Programming Mode)