How to Replace the Stationary
Knife
1
Before
replacing
the
stationary
knife,
disconnect
power
line plug
from
the wail
receptacle.
The
stationa_
knife
shou{d
be changed
when
it
becomes
duH,
The stationary
knife can be replaced according
to
the directions
provided,
however
if there are any
difficulties
experienced,
consult
your
Singer
representative
to make the adjustments,
Be sure that the power fine plug is disconnected
from the electric source.
Open the _ooper cover and set the movable upper
knife
1 in the nonworking
position (page 25)
Loosen the stationa_
knife set screw 2 and remove
the stationary knife 3.
• Ptace a new stationary
knife in the groove of the
s_ationary knife hoider,
o Tighten stationary knife sef screw 2
• Return the movable
upper knife
1 to its working
posiflon,
47