Four Conductor
Wire Connection
to Range
Where
local codes does NOT permit connection
of
the frame grounding
conductor
to the neutral
wire
of the copper
power supply cord (see Figure 7)
1. Remove the screw which is fixing the rear wire cover,
then remove the rear wire cover (access cover) to
expose range terminal connection block (see Figure 5).
2.Remove the ground strap from the terminal block and
from the appliance frame.
3. Using the nuts supplied in the literature package,
connect the ground wire (green) of copper power
supply cord to the frame of the appliance with the
ground screw, using the hole in the frame where the
ground strap was removed (see Figure 7).
4.Connect the neutral of the copper power supply cord
to the center silver-colored
terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
5.Put back the rear wire cover using the screw
removed on step 1.
Terminal Block
Silver Colored Terminal
Direct
Electrical
Connection
to the Circuit
Breaker,
Fuse Box or Junction
Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic
sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief
at each end
of the cable. At the appliance end, the cable goes
through the Direct Connection
Hole (see Figure 7) on
the Cord Mounting Plate. Wire sizes (copper wire only)
and connections
must conform to the rating of the
appliance.
Where
local
codes
permit
connecting
the
appliance-grounding
conductor
to the neutral
(white)
wire (see Figure
8):
1. Be sure that no power is supplied on the cable from
residence.
2. Remove the grounding strap from the terminal block
and from the appliance frame.
3. In the circuit breaker, fuse box or junction box:
A) Connect the green (or bare copper) wire, the
white appliance cable wire, and the neutral (white)
wire together.
B) Connect the 2 black wires together.
C) Connect the 2 red wires together.
Black Wire
I
1 1/8" (2,9cm) |
Dia. Direct
I
Connection
Hole. Punch
Out Knockout
for 1 3/8" (3,5
cm) Dia. Cord
Kit Hole.
A User Supplied
Strain-relief Must
Be Installed at
This Location
To 240 V Receptacle
NOTE: Be sure to remove the
supplied grounding strap.
Figure 7
Red
Wire
Cable from Residence
NOTE: Be sure to remove the
supplied grounding strap.
........
--
Black
Wires-
Box
Wire
U.L.-tisted Conduit
Connector (or CSA
listed)
Figure 8
3-Wire (Grounded
Neutral)
Electrical
System
(Example:
Junction
Box)
9